Business-Critical Continuity " Secure Power For Mission Criticai Applications Network Power

Open the catalog to page 1
Chloride 80-NET - 2

Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power is the leader in the "business-criticalcontinuity" field, thanks to the company's products and services. Emerson Network Power's broad technology base and global expertise support a full spectrum of enterprise-wide solutions for today's vital business needs. More standardization, so you don't need further budget allocations to install it. don't need to be a specialist to get the best for your business....

Open the catalog to page 2
Chloride 80-NET - 4

transformer-free design with full ICBT double conversion provide extraordinary savings costs, while at the same time providing first class load Chloride 80-NET also features a full ICBT rectifier allowing for sets, circuit protection, cabling adapted to meet diverse battery backup time, power, Maximum flexibility is also ensured from: ■ Output Power Factor 1 • Output Power Factordiagram symmetrical respect to zero derating with any load Optimum space/power ratio Full compatibility with static transfer switches Wide range of standard options including: Isolation UPS cabinet), System Bypass...

Open the catalog to page 4
Chloride 80-NET - 5

Current, voltage and frequency values of the three input phases. Alerts of anomalies on bypass. rectifier, inverter, booster/ charger, batteryand load. Date and time of important UPS events, alarms and other Voltage, current and frequency values of each Internal functional Status/values including temperature, cell voltage, capacity Status of the Chloride UFE*net Voltage, current, frequency.

Open the catalog to page 5
Chloride 80-NET - 6

Advanced digital technology and maximum energy savings platform incorporates double most powerful control in the UPS industry. Together with the patented Vector Control increased performance of power converters and real time control of output power quality. This combination of technology provides the following benefits: • Zero impact on upstream • Perfect compatibility with specific unbalanced load • Perfect load sharing for parallel configurations • Enhanced fault clearing inverternominal current} • Intelligent double conversion highest energy savings. Maximum Energy Savings free...

Open the catalog to page 6
Chloride 80-NET - 7

Respecting The Environment Chloride 80-NET respects the highest level of environmental standards as a result of the following features: Premium energy savings Most silent UPS in its power range Maximized battery life with Advanced Battery Care (ABC). ABC allows the 80-NET series to maximize the running time of the battery by up to 50% and includes the following main battery care features: Ambient temperature compensated battery charger Automatic battery test (can be set by user at selectable intervals) Time compensated end of discharge voltage Exact determination of remaining battery life...

Open the catalog to page 7
Chloride 80-NET - 8

Chloride LIFE®.net 24/7 Remote Diagnostic System Chloride LIFE®.net ensures that your critical power protection system is maintained in an optimum state of readiness at all times. Chloride LIFE®.net remote diagnostic and monitoring system provides early warning of UPS and single module alarm conditions and out of tolerances. This allows effective proactive maintenance and fast incident response, giving customers complete security and peace of mind. Maximize Availability Pre-Emptive Maintenance Chloride LIFE®.net provides early warning of more than 150 separate parameters allowing real-time...

Open the catalog to page 8
Chloride 80-NET - 9

The monitoring of environmental conditions where the UPS systems are installed. Software Connectivity Chloride MopUPS Professional provides the safe shutdown of the operating system in the event of an interruption to the load. This includes event logging and gives notications via e-mail. Chloride ManageUPS CIO software provides a central management system for critical power infrastructures distributed within a building, campus or wide area network environment. Hardware Connectivity 9

Open the catalog to page 9
Chloride 80-NET - 10

Flexibility And Security Customize and adapt your system to achieve maximum reliability, exibility and performance. Parallel Ready Chloride 80-NET can be connected with up to eight units in parallel. A single Chloride 80-NET unit can be upgraded to parallel via easy to modify software settings that allow the system to be customized for the requested conguration. Chloride 80-NET’s self conguring, hot plug parallel feature means that the system automatically detects when new units have been added without the need for stopping the system. This simplied parallel process provides maximum...

Open the catalog to page 10
Chloride 80-NET - 12

Chloride 80-NET Specications Technical Characteristics Rating (from 60 - 120 kVA) 60 80 100 120 Output active power at 40° C (kW) 60 80 100 120 Apparent nominal output power at 40° C (kVA) 60 80 100 120 Apparent nominal output power at 25° C (kVA) 66 88 110 132 Input Nominal primary mains input voltage/voltage range (V)* 400 (250 to 460), three phase + neutral Nominal bypass input voltage/voltage tolerance (V) 400 ± 10% (380 V, 415 V selectable) three phase + neutral Nominal input frequency/frequency tolerance (Hz) 50 ± 10% (60 Hz selectable) Input current distortion (THDi) (%) <3 Primary...

Open the catalog to page 12
Chloride 80-NET - 13

Output active power at40° C (kW) Apparent nominal output power at 40° C (kVA) Apparent nominal output power at 25° C (kVA) Nominal primary mains input voltage/voltage range (V) * 400 (250 to 460), three phase + neutral Nominal bypass input voltage/voltage tolerance (V) 400 ± 10% (380 V, 415 V selectable) three phase + neutral Nominal input frequency ƒ frequency tolerance (Hz) Input current distortion (THDi) (%) Primary input Power Factor Nominal output voltage (V) 400 (380 V, 415 V selectable) three phase + neutral Output voltage stability by load variation 0-100% (%) Complies with IEC/EN...

Open the catalog to page 13
Chloride 80-NET - 14

Emerson Network Power Business-Critical Continuity"Expert Today's successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your data center must be built on a support infrastructure designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each IT change, move or addition will affect the entire support infrastructure so you need products and support that ensure your IT systems will operate reliably in these Get More on line: www.eu.emersonnetworkpower.com

Open the catalog to page 14