Compact structure Compact, lightweight and high panel installationdensity Setting unit (option) Display of various parameters, voltage/current / power and change of the feedback system arepossible. Options The options of heater disconnection alarmfunction and current limit function are available. Various protections functions built-in The thyristor element is protected by melting o f the rapid fuse for short-circuit of load, and b y Phase-angle firing/zero-cross firing gate-off for over-current. For models with acooling fan built-in, alarm is activated and outputis stopped for abnormal heat-sink temperature. The phase-angle firing system and thezero-cross firing system are selectable. The running by the phase-angle firing system at theinitial stage and by the zero-cross firing systemat the normal stage is possible. Self-diagnosis function built-in Zero-cross firing system The self-diagnosis function is built in fo r With the delta-sigma modulation, which controlsevery 1 cycle, the fine control like thephase-angle firing system is possible. abnormal operation, abnormal thyristor elementand abnormal power supply. > 1
Open the catalog to page 1Power supply 10: 100V 11: 110V 12: 120V 20: 200V 22: 220V 24: 240V 38: 380V 40: 400V 44: 440V 99: Others Rated current 010: 10A 020: 20A 030: 30A 050: 50A 075: 75A 100: 100A 150: 150A 200: 200A 250: 250A 300: 300A 400: 400A 500: 500A 750: 750A X00: 1000A Control system/feedback type V: Phase-angle firing voltage feedback / Zero-cross firing A: Phase-angle firing current feedback / Zero-cross firing W: Phase-angle firing power feedback / Zero-cross firing N: Phase-angle firing no-feedback * > 1 / Zero-cross firing C: Zero-cross firing Rapid fuse A; Built-in N: Not provided Setting unit (option)...
Open the catalog to page 2Setting unit Setting: Output (0 to 100%), high/low limits (0 to 100%),ramp setting (0 to 100%), soft-start time setting (1 to 20seconds), heater disconnection alarm setting (loadresistance 0 to 100%, available in models with heate Power supply: Supplied from thyristor unit Working temperature: -10 to 55C Working humidity: 30 to 90%RH (no dew condensation) Weight: About 50g Heater disconnection alarm Detects the heater disconnection by built-in or external CT.When disconnection is detected, LED blinks and alarmcontact output becomes ON. The selection of phase-anglefiring system/zero-cross firing...
Open the catalog to page 48 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
14 Pages
4 Pages
6 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
6 Pages
2 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
12 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
2 Pages
6 Pages
8 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages