Three-Phase JW
6Pages

{{requestButtons}}

Catalog excerpts

Three-Phase JW - 1

JW SERIES Three Phase Thyristor Regulator JW series is a three-phase control thyristor regulators having compact size and lighter in weight. There are two control systems, the phase control system and the zero-cross control system. In the phase control systems, a type with the voltage, current and power feedback control systems and a type without those feedbacks are available according to the characteristics of a heater used. JW series is also capable of advanced three-phase control based on 6-arm control and fine control setting by the setting communications unit. Furthermore, remote control and data monitoring is available by communicating to a host unit. FEATURES Compact all-in-one configuration Narrow width unit enables a closed mounting. As they are using the same pitch of old JT series, a replacement by an old version is easy. Setting communications unit is prepared Displaying measured values of real time power voltage, current, electric power and also settings of each parameter, switching operation are available. Each parameter enables fine control. A unit having communications enable to monitor a data and to set up a parameter by the PC through RS422A / RS485. Disconnection alarm and current limit are provided as a standard Heater disconnection alarm function and current control function. (Heater disconnection alarm function is not applicable for SiC heater.) 6-arm control employed as standard 6-arm control is employed to all models to improve controllability. 6-arm control particularly in the transformer loading is the best for improving controllability, handling imbalance load and reducing harmonic noise. Various protective functions Thyristor elements are protected by gating off for over-current, melting of the rapid fuse for short circuit and gating off for over-heating of heat sink. Phase-sequence abnormalities alarm and open-phase alarm, which are suitable for three phase control are included. External transformer specification Damage by abnormal voltage such as surge is reduced by dividing synchronized signal input (control circuit power input) from main circuit and connecting external terminals. Control system V: Phase-angle firing. Voltage feedback/ Zero-cross firing A: Phase-angle firing. Current feedback/ Zero-cross firing W: Phase-angle firing. Power feedback/ Zero-cross firing N Phase-angle firing. No-feedback/ Zero-cross firing Z: Zero-cross firing Rapid fuse *3 N: None A: Built-in Setting communication unit *4 0: None 1: Built-in setting unit 2: Panel-mount setting unit 3: Built-in setting communications unit 4: Panel-mount setting communications unit CT( current transformer) *5 0: Mounted externally( or none) 1: Built-in *1 In case the external transformer spec 4x is selected, an exclusive external transformer kit “SH-JWT40” is required. Please ask for available power voltage “99”. *2 Less than 50A can not be selected when a power voltage is the external transformer spec. Please ask for a rated current 750A and 1000A. *3 Built-in rapid fuse is not available to the rated current 10A or 20A. *4 For panel-mount setting unit, an exclusive cable “SH-JUK3”(3m) or “SH-JUK5”(5m) is required. *5 Built-in CT function is not available to the rated current 100A or more. When installing CT externally please select 0.

Open the catalog to page 1
Three-Phase JW - 2

GENERAL SPECIFICATIONS Phase: Rated voltage: Three-phases Cooling system: Natural air cooling for 75A or less of rated current 200V AC (200V/ 220V/ 240V selectable by switch) Forced air cooling for 100A or more of rated current 400V AC (380V/ 400V/ 440V selectable by switch) Working temperature: to be specified (main circuit power supply and -10°C to 55°C control circuit power supply are common) In case of more than 40°C it depends on the *External transformer spec is available for 400V following derating performance. Rated current: 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 250A, 300A,...

Open the catalog to page 2
Three-Phase JW - 3

FRONT PANEL TERMINAL ARRANGEMENT Front setup part Setting function Ramp (0 to 100%) Elevation (0 to 100%) Soft start (Approx 1 to 20 sec.) Current limit (0 to 100%) Ratio of heater disconnection(0 to 100%) Imbalance ratio(1 to 40%) Output gain of imbalance adjustment*1: Approx ±40% of firing V phase output of imbalance adjustment*1: Approx ±40% of firing against gain W phase output of imbalance adjustment*1: Approx ±40% of firing against gain *1 It is not output adjustment range. Output adjustment range is approx 10%. Setting function Current limit ON/OFF. ON to activate. Heater...

Open the catalog to page 3
Three-Phase JW - 4

CONNECTION OF SETTING TERMINALS Control input signal only Current signal (4 to 20mA DC) Manual setting unit and with auto/man switching Current signal (4 to 20mA DC) With ramp setting unit (Ramp using control input signal) Current signal(4 to 20mA DC) Manual setting unit only With elevation setting unit Current signal (4 to 20mA DC) Manual setting unit, ramp setting unit with auto/man switcing Current signal (4 to 20mA DC) With ramp setting unit (Ramp using remote setting input) Current signal (4 to 20mA DC) * Output of voltage output unit needs to be insulated to connect multiple units...

Open the catalog to page 4
Three-Phase JW - 5

Setting Communication unit Unit: mm *M16 for 500A type *1 External transformer terminals (synchronized signal terminals) is provided as an option for external transformer spec *2 Setting terminals and external transformer terminals are installed inside cover

Open the catalog to page 5
Three-Phase JW - 6

ACCESSORIES Built-in rapid fuse (for replacement) Manual setting unit All-in-one function combined with indicator, ramp setting, manual setting and selector switch Variable resistance value: 10kΩ (Ramp setting) 2kΩ (Manual setting) 2: Voltage indicator (0 to 250V) 4: Voltage indicator (0 to 500V) Rated current Simple function type for ramp setting Variable resistance value: 10kΩ *Manufactured by HINODE ELECTRIC CO., LTD External mounted rapid fuse unit Rated current External transformer kit for 4X CT (external current transformer) Rated current External down transformer (Y-Y) Arrester...

Open the catalog to page 6

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages