Strip Chart Recorder EL3000 dotting
4Pages

{{requestButtons}}

Catalog excerpts

Strip Chart Recorder EL3000 dotting - 1

ANALOG RECORDER (DOT PRINTING TYPE) EL3000 series is a dot printing type analog recorder sized 144x144mm with 100mm width chart. The unit starts recording as soon as the power supply and input are connected and it is also easy to operate. Scale plate, input range and function of the recorder can be selected for various purpose and applications as many kinds of options are prepared. FEATURES Universal power supply Universal power supply with voltage range of 100 to 240V AC (50/60Hz) is applied. Linear temperature scale Temperature scale of thermocouple and resistance thermometer input is a linear scale that is excellent in reading indication value. Standard 6 chart speeds 6 chart speeds (5,10,20,40,80,160mm/h) are switchable as standard. 5 chart speed and hour/minute change are prepared as option. Alarm setting (common alarm) as standard Higher and lower limit alarm can be programmed for every point. Alarm value is easy to be programmed by pointer location. You can check the alarm by front LED lighting. Alarm output is prepared as option. CE marking The EL recorder is conformed to the rules of safety standards of CE. (Conformity pending) Unit structure and light-weight Light-weight (50% of the previous unit weight) was realized by easy maintenance unit structure. Employing removable type terminal board Employing easy connecting removable type terminal board. Input point 1 : 1point 2 : 2points 3 : 3points 6 : 6points Input signals 5 : Thermocouple/DC voltage 7 : Resistance thermometer Thermocouple with burnout/DC voltage Built-in voltage divider input (option)*1 Input and scale plate (option)*2 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input, and built-in voltage divider) + standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input, and built-in voltage divider) + Non-standard scale plate Alarm output (option) 0 : None 1 : 2 alarm outputs Chart speed and burnout (option) *3 0 : Standard 6-speed+ burnout disabled 1 : Standard 6-speed + up-scale burnout 2 : Standard 6-speed + down-scale burnout A : Standard 5-speed hour/minute change + burnout disabled B : Standard 5-speed hour/minute change + up-scale burnout C : Standard 5-speed hour/minute change + down-scale burnout) *1: Optional built-in voltage divider and thermocouple/residence thermometer burnout input is only type "7". *2: Double scale is available. Input and scale selection are needed for non-standard input and non-standard scale plate. *3: Burnout on all channels is programmed together for thermocouple/residence thermometer input.

Open the catalog to page 1
Strip Chart Recorder EL3000 dotting - 2

OPERATION / PROGRAMMING SPECIFICATIONS INPUT SPECIFICATIONS Measurement point: Reference range and types: 1,2,3 and 6 points DC voltage --- ±13.8mV, ±27.6mV, ±69mV, 200mV, ±500mV,±2V, ±5V Built-in voltage divider; ±10V, ±25V, ±50V DC current --- External installation of shunt resistor(250Ω) is applied (option) Thermocouples --- K, E, J, T, R, and B (option) Resistance thermometer --- Pt100(1997) (Measured current; 1mA) * Linear scale for thermocouple and resistance thermometer Input designation: Single scale (standard), double scale (option) Accuracy rating: ±0.5% of input span (except for...

Open the catalog to page 2
Strip Chart Recorder EL3000 dotting - 3

OPTION SPECIFICATIONS Options Alarm output DC current input Built-in voltage divider Non-standard input Non-standard scale plate Standard range and minimum width of scale Contents Alarm contact output is available Alarm relay --- Mechanical relay 1a contact, 2 outputs (common) Maximum contact rating --250V AC 2A, 30V DC 2A(resistive load) 250V AC 0.5A, 30V DC 0.5A (inductive load)) 250Ω of shunt resistor is applied to measure voltage input Built-in voltage divider(1/1000) measures input in the range of ±5V to ±50V (input type "7" only) Refer to the table of standard range and programmable...

Open the catalog to page 3
Strip Chart Recorder EL3000 dotting - 4

TERMINAL BOARD DEMENSIONS Panel cutout Minimum clearance for plural installation Specifications subject to change without notice. Printed in Japan (I) 2006. 2 Recycled Paper 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jp Website: http://www.chino.co.jp

Open the catalog to page 4

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages