Standard radiation thermometer IR-RST
2Pages

{{requestButtons}}

Catalog excerpts

Standard radiation thermometer IR-RST - 1

STANDARD RADIATION THERMOMETER Model IR-RST series Standard Radiation Thermometer IR-RST series has been developed under collaborative research with the National Metrology Institute of Japan (NMIJ). The IR-RST series as Standard Radiation Thermometers are applicable for traceability of calibrating conventional radiation thermometers. Based on Japan Industrial Standard JIS C 1612 (Test methods for radiation thermometers), two models of 0.9µm and 0.65µm in measuring wavelength are prepared. 0.9µm model supplies JCSS** calibration which certifies temperature range from 400 to 2000ºC by fixed point calibration method with fixed point blackbody furnace IR-R0 (Zn 420ºC to Cu 1085ºC) and comparison calibration method with comparison blackbody furnace IR-R8. 0.65µm model supplies calibration upto 3000ºC by fixed point calibration method and comparison calibration method with high-temperature fixed point blackbody furnace IR-R80 utilizing metal-carbon eutectics fixed points (upto 2474ºC) developed by NMIJ. JCSS** = Japan Calibration Service System FEATURES Undertaking collaborative research with NMIJ, specifications and performance as high-precise standard radiation thermometer is realized. By utilizing two models of 0.9µm and 0.65µm units, calibration from 400 to 3000ºC with the small uncertainty is realized. 0.9µm unit is applicable for 4-fixed points calibration by JCSS. 0.65µm unit can be calibrated on high-temperature fixed point furnace utilizing metal-carbon eutectics fixed points. (Φ0.6mm at 400mm) Embedded internal temperature control eliminates the need for output variation compensation against ambient temperature. Prepare various calibration test in accordance with uncertainty. APPLICATIONS Standard Radiation Thermometer for National Standard Laboratories, or Calibration Agencies High-precise Radiation Thermometer for the purpose of delivery inspection, periodical check and quality control at blackbody furnace user, high-temperature furnace manufacturer and user.

Open the catalog to page 1
Standard radiation thermometer IR-RST - 2

SPECIFICATIONS Models Measuring method Detecting Element Measuring Wavelength Measuring Range Range : L :M :H Resolution Response Time (95%) Optical System Lens Aperture Measuring Distance Distance factor (Minimal target size) Targeting Output Power Supply Working Temperature Range Casing Weight Mounting CE approval Output stability under test condition of EMC directives Direct View Finder Radiation luminance: 0 to 10V DC (with zero adjustment) Internal temperature: 0 to 5V DC (0 to 50ºC) 24V DC ± 10% 5 to 35ºC Aluminum Approx 2.8Kg Tripod mounting or 4-pc of M5 screws EMC directive...

Open the catalog to page 2

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages