Group: Industrial Process Instrumentation
Catalog excerpts
TYPE HYBRID MEMORY RECORDER AL4000 series is a hybrid recorder which employs bright and clear, easy to view LCD display. Measuring value display is prepared as 1 point display, multi-points simultaneous display and digital display + bar graph display. Various measuring and recording settings can be easily done by front key switch and confirmed by LCD digital display. FEATURES Corresponds to SD card Equipped with SD card (sold separately) and it can record data, read and write setting value. Full multi range Equipped with DC voltage 10 kinds, T/C 36 kinds, RTD 12 kinds, in total 58 kinds. Easily set the range per channels. Easy data management by communication interface Provided with USB port and connect with PC directly. RS232C, RS422A, RS485 and Ethernet communication interface is optionally prepared. When Ethernet is selected, settings from the web and E-mail alarm notification are added. Package Software attached By Data acquisition software, the use of application expands from recording/management to information processing. *Optional communication interface required. Data analysis software can replay display, wave form process, editing and trend display. Parameter setting software can manage the setting information on PC. Standard alarm display/ Printing function Set 4 types of alarm per each input points. When alarm occurs, status display “ALM” flashes and measuring value flashes at LCD operation screen. Chart end detection function available Can set the alarm operation when chart end is detected. Various programming function Process the measured data by programming setting and displayed/recorded data of each channels are shown as programmed result data. - NNN Input point 1 : 1 pen 2 : 2 pen 3 : 3 pen 4 : 4 pen Communication interface (option) N : None E : Ethernet R : RS232C A : RS422A/RS485 Q : RS232C+RS485 C : RS422A/RS485+RS485 G : Ethernet + RS422A/RS485 +RS485 Alarm output / remote contacts (option) 0 : None 2 : Mechanical relay 2 points (‘a’ contact) 4 : Mechanical relay 4 points (‘c’ contact) + remote contact 5 points A : Mechanical relay 6 points (‘a’ contact) + remote contact 5 points Power supply A : 100-240V AC
Open the catalog to page 1(2) Operation/ (3) SD card slot Display measured data by digital display and analog indication by bar graph display. 0 1 point enlarged digital display 4 points digital display 1 point enlarged digital display + bar graph display I 4 points pointer display Setting contents can be easily registered by front key switch. frf?B^) (<FTjNC^) (#UNc5) (ENTE^ Press (Menu) key and menu screen (list of setting items) will be Save measured data to SD card by designated interval (Fastest 0.1 sec). Also, register measuring / recording condition such as range, scale, chart speed and when required, setup...
Open the catalog to page 2PERFORMANCE SPECIFICATION Periodic data printing Record the data with time, channel no., data, unit over trace printing by arbitrary interval Time Digital recording ►List printing Print setting data such as range, scale etc. for each channel. Trace printing Chart speed ►Data print When the latest data is required, trace printing will stop and recorded. Time Digital recording ►Alarm activation and reset printing When alarm activates/reset, prints time, channel no., alarm type and alarm no. Trace printing -Scale/Tag, Burnout Alarm reset channel number Alarm activation Alarm reset time Alarm...
Open the catalog to page 3AL4000 SERIES INPUT SPECIFICATIONS DISPLAY SPECIFICATIONS Measuring points: 1 to 4 points Input types: DC voltage --- ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±1V ±5V, ±10V, ±20V, ±50V DC current --- Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately) Thermocouple --K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel , Au/Pt Resistance thermometer --Pt100, old Pt100, JPt100, Pt50, Pt-Co Accuracy ratings: Refer to the table of measuring range/accuracy ratings/display resolution Measuring interval:Approx. 100ms Input resolution: About...
Open the catalog to page 4Alarm printing: Alarm activated --- Time, channel no., alarm type and level Alarm reset --- Time, channel no., alarm level Memory capacity --- Max. 48 data List printing: When required, interrupt trace printing and print date, chart speed and setting information of each channel. Message printing: Print when required Up to 15 characters/message, register up to 20 types. ON/OFF of display and recording: Select ON / OFF of display trace recording to chart, digital recording to chart, recording to SD card per each channel. Subtract printing: Record difference between reference channel and...
Open the catalog to page 5MEASURING RANGES/ACCURACY RATING/DISPLAY RESOLUTION Remote contact: Model : RZ-SMC512 Model : RZ-SMC1G Model : RZ-SMC2G Input type By external relay contact signal (digital contact: short or open), you can select chart speed or data printing Input points: 5 points Input signal: Digital contact signal or open collector signal Contact capacity: 5V DC/2mA Function: 1. Record start/stop 2. Chart speed 3-speed switch 3. Data printing 4. List printing 5. Message printing 6. Operation record (Record ON/OFF condition to the designate location by bar line) 7. Integration/F value reset 8. Memory card...
Open the catalog to page 6Exceptions for accuracy ratings Input type Exceptional range TERMINAL ARRANGEMENT Alarm relay output (6 points ‘a’ contact) + remote contacts and communication interface Communication terminal (option) 1 2 3 4 5 6 7 8 RS-232C SG SD RD RS-422A SG SDA SDB RDA RDB RS-485 SA SB SG Power/protective conductive terminals N PE L 100-240V AC Remote contact terminals (option) Alarm output terminals (option) Measurement input terminals TC.mV(+), RTD(A) terminals TC.mV(-), RTD(B) terminalsminals RTD(B) terminals Ethernet connector Alarm relay output (4 points ‘c’ contact) + remote contacts and...
Open the catalog to page 7APPLICATION SOFTWARE (standard attached) Data Acquisition Software You can acquire data easily to your PC. Parameter Setting Software *Optional communication interface required Control the setting information at PC by using communication interface or USB port (standard equipped) List Data Screen Trend Data Screen Data Analysis Software Open the binary file recorded in the SD card, replay display and edit the trend of acquired data file. DIMENSIONS *Max241, When alarm output/remote contacts unit and communication unit are added. 179 220 (Max220, When Ethernet unit are added.) Panel cutout...
Open the catalog to page 8All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages