Overview: The HN-CJ series is a separated type thermo-hygrometer designed for high-pressure and high-temperature environments, capable of operating up to 1MPa and 180ºC. It is suitable for measuring temperature and humidity in pressurized and high-temperature conditions, with enhancements for relative humidity measurement above 100ºC and robustness in hydrogen environments.
Features:- Pressure-proof up to 1MPa and high temperature up to 180ºC.
- Humidity measurement capability above 180ºC dew-point temperature.
- Interchangeable plug-in sensor for ease of maintenance.
- High reliability and ruggedness in hydrogen environments.
- High-polymer film capacitance type sensor for relative humidity measurement from 0%RH.
Models:- HN-CJA: Outputs temperature and relative humidity.
- HN-CJC: Outputs temperature and dew-point temperature.
Specifications:- Output Signal: Temperature & relative humidity or temperature & dew-point temperature.
- Measuring Range: 0 to 100%RH, no dew condensation, maximum dew-point temperature 150ºC.
- Accuracy: ±2%RH at 0 to 90%RH and 25ºC, ±3%RH at 90 to 95%RH and 25ºC.
- Temperature Coefficient: ±0.05%RH/ºC at 5 to 80ºC.
- Response Time: Within 30 seconds for 90% response.
- Temperature Range: -40 to 180ºC.
- Accuracy: ±0.5ºC at 25ºC, ±0.5±0.002|T-25|ºC.
- Power Voltage: 12 to 24V DC ±1V.
- Output Signal: 4 to 20mA DC 2-wire transmission.
- Resistive Load: Lower than 500Ω at 24V DC power supply.
- Working Temperature: 0 to 50ºC for the main unit, -40 to 180ºC for the probe.
- Material: Main unit made of resin, probe made of SUS316.
- Mounting: By screws (M4 x 2) or DIN rail.
- External Dimensions: W90 x H90 x D45 mm.
- Weight: Main unit approx. 220g, probe approx. 350g.
- Interchangeability: Plug-in cable can be replaced.
Accessories: Includes wall-mounting hardware.
Additional Notes: Humidity units convertible with HN-CJA and HN-GV1F, including absolute humidity, relative humidity, mixing ratio, water vapor pressure, and dew-point temperature.