THERMO-HYGROMETER HN-C series HN-C series using newly developed humidity element are high performance and highly reliable 2-wire transmission type thermo-hygrometers for the wide measuring range of 0 to 1 00%. Models with temperature output of 3-wire type PT100 is available. Wall -mount type, separated type and inserting type are available for various applications. Heat-resistive separated type, which can be used in the operating temperature of –40 to 180ºC, is available, too. l Newly developed humidity element is built-in for Q: Wall-mounting type F: Separated type G: Heat-resistive separated type V: Inserting type (Soft type) P: Inserting type (Hard type) improving reproducibility reliability. l Measurable relative humidity is 0 to 100%RH by the capacitance type element. l Five types of wall-mount type, separated type, heat-resistive separated type, and inserting type (soft type and hard type) are available for various applications. l The sensing part of the heat-resistive separated type can be used in the operating temperature of -40 to 180ºC. l Interchangeable sensing part for easy maintenance A:Temperature: 4 to 20mADC (2-wire transmission) Humidity: 4 to 20mA DC (2-wire transmission) B:Temperature: Pt100 3-wire type Humidity: 4 to 20mA DC (2-wire transmission) l Mounting on DIN rail is possible. (except inserting type) l Confirms to CE-marking. *1 In the case of separated type and heat-resistive separated type, the output signal is only A. *2 Only for separated type and heat -resistive separated type. Others are blanks MAJOR APPLICATIONS l Measurement and control of temperature/ humidity in environment testing machines, chambers and clean benches l Measurement and control of temperature/ humidity of food storage houses, grain storage houses and green houses l Measurement and monitoring o temperature/ f humidity of exhausting ducts Instrument (Temperature) l Measurement and monitoring of temperature/ humidity of baking chambers Instrument (Humidity)
Open the catalog to page 1GENERAL SPECIFICATIONS Wall-mounting type Model Element Measuring range Accuracy ratings Coefficient of relative humidity/temperature Response time (90% response) Output signal Resistance load 0 to 100% (No dew condensation) ±2 %RH (at 0 to 90%RH and 25 ºC); ±3 %RH (at 90 to 95%RH and 25 ºC) ±0.1%RH / ºC (at 5 to 80ºC) Shorter than 1 min (same conditions as left) Within 15 sec. (at 25 ºC and wind speed of 0.1 m/s) HN-C__A: 4 to 20mA DC; 2-wire transmission Lower than 500W (at 24VDC power voltage); Platinum resistance thermometer; Pt100 JIS, 0 to 50 ºC -40 to 80 ºC Element Measuring range...
Open the catalog to page 2PERFORMANCE SPECIFICATION HUMIDITY CONVERTER HN-G GENERAL SPECIFICATIONS lAssembly with HN-C series (HN-GV1) Input signal : Humidity HN-GV1 Humidity Converter for HN-C series Assembly enable meters Input signal: Humidity: 4 to 20mADC Input range : Humidity : 0 to 100% RH Temperature: 0 to 50oC; 0 to 80oC; lAssembly with HN-Z series (HN-GZ8) Input signal : Humidity : 4 to 20mA DC Temperature : Pt100 JPt100 3-wire type Input range : Humidity : 0 to 20kPa or 0 to 50kPa Temperature : 0 to 300oC lCommon specification of HN-GV1, HN-GZ8 Output signal : humidity/temperature: 4 to 20mA DC (Load...
Open the catalog to page 3PERFORMANCE SPECIFICATION DV POWER SUPPLY HN-W1A CONNECTIONS GENERAL SPECIFICATIONS Output voltage : 24V ±1V DC Output current : 0.3A Power supply : 90-100/180-220V AC, 50/60Hz Working voltage : ±10% of rated value Working environment temperature : -10 to +50oC Working environment humidity: 10 to 90%RH (non condensation) Insulation resistance : Between output terminal and ground over 100MΩ at 500VDC Between power terminal and ground over 100MΩ at 500VDC Resisting voltage : Between power terminal and ground terminal 1 minute at 1500VDC Between output terminal and ground terminal 1 minute at...
Open the catalog to page 4All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages