KR3000 - 1

GRAPHIC RECORDER KR3000 Series are network-compatible paperless recorders with high performance and high operating function employed high visibility 12.1" TFT color LCD display and touch panel operation system. High speed of sampling rate 100ms for all points* and high accuracy of ±0.1% were realized, and measured data is stored into internal memory and maximum 8GB compact flash card (CF card). As it can be monitored by a web browser display on several computers on intranet or internet, FTP transfer of data file and E-mail notification are also available. FEATURES Large sized 12.1” TFT color LCD display . Large-sized high visibility display with various display functions. Real time/Historical trend screen, Bar-graph screen, Data screen are selectable for various applications. . Combination display for selected 4 screens is available. It is easy to switch to individual screen by touching panel. Large capacity of data memory and various recording method . Compact flash card (CF card) slot is equipped as standard external memory. Large capacity storage of maximum 8GB is available. . Various data storing methods are selectable such as schedule programming by time of day and time of date, recording startup by external signal and event, and data logging of before and after trigger points for alarm. Multi points recording with high speed/high accuracy . High-speed recording of approximately 100ms for all points* and high accuracy of ±0.1% were realized. Stable measuring and recording are possible with high speed. . High withstand voltage of 1000V AC between input channels. (Except resistance thermometer input) Easy operating and programming without manuals . Easy operating by dedicated keys for each function and touch panel. . Various functions such as scrolling of real time trend and historical trend by panel touching are available. . USB port is prepared in front compartment. Setting file and data file are stored in USB memory stick. Writing comments on screen . Comments can be written on screen by a stylus pen. Setup and display of CHINO controllers . Parameter setting and recording/displaying of setting/measuring value by connecting maximum 16 units of CHINO controllers to low-order communications (option) LAN network capability . Various networked environment such as remote monitoring by browser, FTP server, FTP client and E-mail notification are applied as Ethernet is equipped as standard. Analyzing/data acquisition application software . It is easy to replay and edit the recorded data file. Replay display has functions of vertical/horizontal trend, circular trend, and also wave-analyzing and marking by using the cursor. MODELS KR31 Measuring points/sampling rate* 20: 12 points/100ms 40: 24 points/100ms 60: 36 points/100ms 80: 48 points/100ms 21: 12 points/1s 41: 24 points/1s 61: 36 points/1s 81: 48 points/1s Communications interface (option) N : None R : High-order (RS232C) S : High-order (RS422A/RS485) Digital input/ alarm output (option) 0: None 1: Alarm output 12 points (a contact) 2: Alarm output 6 points (c contact) 3: Alarm output 24 points (a contact) 4: Alarm output 12 points (c contact) 5: Alarm output 12 points (a contact) + 6 points (c contact) A: Digital input 8 points B: Digital input 8 points + alarm output 12 points (a contact) C: Digital input 8 points + alarm output 6 points (c contact) D: Digital input 8 points + alarm output 24 points (a contact) E: Digital input 8 points + alarm output 12 points (c contact) F: Digital input 8 points + alarm output 12 points (a contact) + alarm output 6 points (c contact)

Open the catalog to page 1
KR3000 - 2

• Real-time trend screen Displays data (measured and virtual) of selected group. Vertical trend and horizontal trend selectable. Data screen Displays data (measured and virtual) of selected group. Simultaneous display of alarm status. Switchable from displayed 4 screens to individual screen

Open the catalog to page 2
KR3000 - 3

General functions --- Round-up, round-down, absolute value, square root, exponent of e, natural logarithm, common logarithm Integration operations --- Analog integration, digital integration Channel data operations --Measured data computation, calculated data computation moving average, previous data, first order lag filter Others --Dew point, relative humidity, F-value wind direction, 16 direction display, increment per time (increment per set unit time), remaining amount of CFcard INPUT SPECIFICATIONS Measuring points: Input types: 12 points, 24 points, 36 points and 48 points Universal...

Open the catalog to page 3
KR3000 - 4

PROGRAMMING/OPERATION Operation method: Operation keys: HOME settings: MENU settings: DISP operations: Touch panel/dedicated key HOME, MENU, DISP, MARKER, SCROLL, CURSOR, START, STOP, DIRECTION keys, ENTER, ESC Simple recording settings --- Common setting to all channels Parameter programming for all channels together, recording cycle, selection settings Input/computation programming --- Input parameter, computation parameter DISP Settings --- Data channel parameter, group parameter, common parameter (combination display, trend vertical/horizontal) Alarm settings File settings (6 individual...

Open the catalog to page 4
KR3000 - 5

PERFORMANCE SPECIFICATION MEASURING RANGES/ACCURACY RATINGS Input type (with built-in voltage divider) Messureing range Accuracy ratings accuracy ratings Note: The accuracy ratings are converted into the measuring range under reference operating condition. Thermocouple input does not contain reference junction compensation accuracy. ■ APPLICATION SOFTWARE ZAILA (sold separately) The software is applied for replay display/wave editing operation of recorded data in KR3000 series. It has replay display of vertical/horizontal trend and circular trend function, and also analyzing function such...

Open the catalog to page 5
KR3000 - 6

PERFORMANCE SPECIFICATION Measuring input Ethernet connector Serial communication terminals (option) Power terminals/protective conductor terminal Thermocouple DC voltage (+)/resistance thermometer (A) terminals - Thermocouple DC voltage (-)/resistance thermometer (B) terminals- Resistance thermometer (B) terminals- Thermocouple DC voltage (+)/resistance thermometer (A) terminals - Thermocouple DC voltage (-)/resistance thermometer (B) terminals- Resistance thermometer (B) terminals- Thermocouple DC voltage (+)/resistance thermometer (A) terminals - Thermocouple DC voltage (-)/resistance...

Open the catalog to page 6

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. Solidpak NC

    6 Pages

  22. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages