The KP3000 series is a 96x96mm digital program setter with the analog output accuracy of ±0.1% and maximum 30 program patterns (maximum 19 steps/ pattern). Output signal can be specified from analog output type and digital output type. By combination with a digital indication controller with digital input, the configuration of low cost program control system is enabled. ■ FEATURES • Program pattern Settings of maximum 19 steps per pattern and maximum 30 sets of patterns are enabled. Repeating of a whole program pattern, linking of program patterns and repeating of a specific step in a program pattern are enabled, too. •Analog output type and digital output type Output of setting unit is selected from high accuracy (0.1%FS) analog output type and digital output type which has no setting error by using communications function. •Communicati ons 2-port type provided Models with 2 communications ports are available. In addition, speeding up and highly-functionalization of communications have been realized. For example, you can use 1 port for high order communications with a personal computer and another port for the communications remote (digital remote) function. The communications protocol can be arbitrarily selected from [MODBUS] and [PRIVATE]. In the digital output type, however, 1-port type of communications is only available. • DI/DO arbitrarily-allocation When the digital input (DI) or the digital output (DO) is added, arbitrarily-allocation for assigning functions to those DI/DO's is enabled. It is the function enabling allocations such as [External drive input] to DI1 to DI3 and [Pattern selecting input] to DI4 to DI6. •Conforming to international safety standards and European directives (CE) The controller is conformity with European directives (CE), and is UL and c-UL approved. •Conforming to RoHS The controller is an environmental consideration product which does not contain directed hazardous substances such as lead, etc. Output signal 1: Digital output (RS422A) 2: Analog output (4 to 20mA) 4: Analog output (0 to 10V) 5: Analog output (0 to 1V) 6: Analog output (Others) 7: Digital output (RS485) 1st zone* 0: None P: 6 Digital inputs T: 6 Digital outputs 2nd zone* 0: None P: 6 Digital inputs*1 T: 6 Digital outputs*1 3rd zone* 0: None R: Communications 1 port (RS232C) + 3 Digital inputs*2 A: Communications 1 port (RS422A) + 1 Digital input*3 S: Communications 1 port (RS485) + 3 Digital input*2 B: Communications 2 ports (RS232C + RS232C) + 1 Digital input*4 C: Communications 2 ports (RS232C + RS422A) + 1 Digital input*4 D: Communications 2 ports (RS232C + RS485) + 1 Digital input*4 E: Communications 2 ports (RS485 + RS232C) + 1 Digital input*4 F: Communications 2 ports (RS485 + RS422A) + 1 Digital input*4 G: Communications 2 ports (RS485 + RS485) + 1 Digital input*4 P: 6 Digital inputs*4 T: 6 Digital outputs*4 U: 8 Digital inputs*4 W: 8 Digital outputs*4 Y: 3 Digital inputs + 5 Digital outputs*4 Z: 4 Digital inputs + 4 Digital outputs*4 Case color G: Gray B: Black Panel sealing and terminal cover* 0: None 1: Terminal cover 2: IP54 panel sealing 3: IP54 panel sealing + Terminal cover -Power supply voltage A: 100 to 240V (AC) D: 24VAC/24VDC * Option *1 It can be selected when the control signal is 1 or 7 only. *2 The digital input is 1 point for the control signal of 1 or 7. *3 It can be selected when the control signal is 2, 4, 5, 6 or 7 only. *4 It can be selected when the control signal is 2, 4, 5 or 6 only. Note: For options common to 1st zone, 2nd zone and 3rd zone, assign them in order of [P] and [T] from 3rd zone first
Open the catalog to page 1Upper display Function keys Operation status (RUN) indication Lights in operation. Operation stop (STOP) indication Lights in the state of operation stop. RESET indication Lights when operation is cancelled and returns to the start point. Program remote (REM) indication Lights when operation is executed by digital input. Executing step number (STP) indication The step No. being executed is indicated. Function (FNC) operation indication Lights when the function key is operated. 15. Set value (SV) indication 16. Time signal (TS1 to TS8) indication FNC key With the operation screen displayed,...
Open the catalog to page 2PERFORMANCE SPECIFICATION Output signal: Analog output 4 to 20mA, 0 to 1V, 0 to 10V Digital output RS422A, RS485 Accuracy rating: ±0.1% of full scale Output updating cycle: Analog output Approximately 0.1 seconds Digital output Approximately 1 second Resolution: Approximately 1/30000 Output impedance:Voltage output Approximately 10Q Load resistance: Current output 400Q or less Voltage output 50kQ or more ■ DISPLAY SPECIFICATIONS Upper display: LED Lower display: LCD (with back light) 108 x 24 dots ■ GENERAL SPECIFICATIONS No. of program patterns: 30 patterns Pattern...
Open the catalog to page 3■ OPTIONS •Communications interface With RS232C, RS422A or RS485, the setting and measured values of the controller can be transmitted to a master CPU and various parameters can be set by the master CPU. Number of communications points: 2 points Communications type: RS232C, RS422A, RS485 Communication speed: 2400/4800/9600/19200/38400 bps Protocol: MODBUS (RTU), MODBUS (ASCII), PRIVATE •Digital signal input The following switching is enabled by digital input signal. Input signal: No-voltage contact, open-collector signal External contact capacity: 5VDC 2mA Functions: 1. Selection...
Open the catalog to page 4PERFORMANCE SPECIFICATION Option terminals Analog output (Voltage/current) Digital output 1 © 25 n 25 25 25 •Digital output + Communications Communications RS232C Communications RS485 © © Digital output RS422A Digital output RS422A 1 digital input 1 digital input Communications RS232C © Digital output RS485 © 1 digital input RD SD SG SA SB SG DI COM Communications RS485 © Digital output RS485 © 1 digital input SA SB SG SA SB SG DI COM Digital output RS485 © Communications RS422A © 1 digital input SA SB SG RDA RDB SDA SDB DI COM •Option terminals Options common to each zone P P: 6...
Open the catalog to page 5All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages