1. Overview and General Description

The IR-CZ Series comprises infrared temperature sensors designed for industrial use, featuring a chopper-less design and semiconductor laser targeting to enable precise, non-contact temperature measurements.

2. Specifications

  • Temperature Range: -10°C to 3500°C, varying by model and diaphragm size.
  • Diaphragm Sizes: φ7mm, φ10mm, φ20mm, φ30mm to control measurement spot size.
  • Emissivity: Adjustable remotely or via automatic calculation; critical for measurement accuracy.
  • Output Signals: 4-20mA analog output for temperature; contact outputs for alarms and errors.
  • Laser Targeting: Built-in semiconductor laser emitter (≤1mW, 645nm, Class 2) for aiming without a viewfinder.
  • Alarm Functions: High/low alarms, error detection, and dirty lens detection.

3. Measurement and Accuracy

High accuracy is achieved with resolution down to 0.015% of the measured value and sensitivity at 0.9μm wavelength. Accuracy depends on temperature range and diaphragm size, with specific calibrations for ranges such as 200-2000°C and 300-3500°C.

4. Installation and Environmental Conditions

  • Operating temperature for the sensor body: -10°C to 60°C.
  • Protection against heat, dust, particles, and sediment via cleaning plugs and window glass options.
  • Air inlet and cleaning ports facilitate maintenance of sensor optics.

5. Electrical and Signal Interface

  • Inputs include 4-20mA DC for emissivity control and analog inputs for external adjustments.
  • Alarm and error signaling via open collector outputs rated at 30V DC, max 50mA.
  • Specified connector types for integration.

6. Operational Features and Recommendations

  • Laser targeting supports peak hold reset, sample hold, and laser on/off functions.
  • Automatic emissivity calculation recommended for varying surface conditions.
  • Regular cleaning of lens and window glass is essential to prevent measurement errors.
  • Alarm outputs should monitor sensor health and environmental conditions.

7. Mechanical and Dimensional Data

Detailed mechanical drawings and dimensions are provided for sensor mounting, diaphragm sizes, and air inlet ports to ensure proper installation and alignment.

8. Limitations and Precautions

  • Measurement accuracy can be affected by environmental factors such as dust, sediment, and furnace wall conditions.
  • Temperature range selection must align with diaphragm size and sensor model for reliable readings.
  • Laser emission is Class 2; safety precautions are necessary during installation and maintenance.

9. Summary of Key Parameters

ParameterValue/RangeNotes
Temperature Range-10°C to 3500°CDepends on diaphragm and model
Diaphragm Sizesφ7mm, φ10mm, φ20mm, φ30mmControls measurement spot size
Output Signal4-20mA DCAnalog temperature output
Laser TargetingSemiconductor laser ≤1mW, 645nmClass 2 laser, no viewfinder
Alarm OutputOpen collector 30V DC, max 50mAHigh/low alarms, error signals
EmissivityRemote adjustable or automaticCritical for measurement accuracy

10. Maintenance and Troubleshooting

Regular inspection and cleaning of the sensor window and diaphragm are necessary to avoid errors caused by dust, sediment, or damage. The sensor includes self-diagnostic and dirty lens detection features to alert operators.

Conclusion

The IR-CZ Series sensors offer precise, non-contact temperature measurement suitable for harsh industrial environments. Optimal performance depends on correct diaphragm and temperature range selection, regular maintenance, and use of integrated laser targeting and alarm functions.

See more

Catalog excerpts

IR-CZ series-1

300 with field diaphragm φ10mm 200 with field diaphragm φ10mm 300 with field diaphragm φ10mm 300 with field diaphragm φ10mm 300 with field diaphragm φ10mm 200 with field diaphragm φ 200 with field diaphragm φ 200 with field diaphragm φ

 Open the catalog to page 1
IR-CZ series-2

IR-CZ SERIES ,.μm) uses a chopper-less structure

 Open the catalog to page 2
IR-CZ series-4

IR-CZ SERIES C / C or 0.015% / C of measured value whichever larger φ20mm or φ10mm with field diaphragm

 Open the catalog to page 4
IR-CZ series-5

Sediment at furnace hole Window glass ! Temperature output 4-20mA Lack of view alarm output Dust / particles Furnace wall Analog input (Connector type only) Input signal: 4 to 20mA DC Selectable from emissivity remote setup or automatic emissivity calculation Contact input (Connector type only) 1 point: Peak hold reset or Sample hold or Laser on/off Dry contact or Open collector Contact output (Connector type only) 2 points: High (low) alarm or Error signal (self-diagnostic) or Dirty lens detection (2-colour model) Open collector 30V DC, Max. 50mA Laser targeting Built-in semiconductor laser...

 Open the catalog to page 5
IR-CZ series-6

IR-CZ SERIES "#" ■ The soft protective case IR-ZZCS is an exclusive accessory for the IR-CZ series to protect the thermometer from smoke, dust, etc at the installation site. This unit provides air-purge to remove smoke and dust for keeping the lens clean. Use clean instrumentation dried air. (Common use for connector type and terminal type) ■ The hard protective case IR-ZCCHT is an exclusive accessory for the IR-CZ series to protect the thermometer from high-temperature, humidity, smoke, dust, fume, etc. This unit provides air-purge and water-cooling to operate the thermometer properly in harsh...

 Open the catalog to page 6

All CHINO CORPORATION catalogs and technical brochures

  1. TRAMS IV

    4  Pages

  2. LH100

    4  Pages

  3. General Catalog

    14  Pages

  4. IR-BAT SERIES

    4  Pages

  5. IR-FA SERIES

    6  Pages

  6. IR-TA SERIES

    2  Pages

  7. MODEL IR-TE

    2  Pages

  8. On-line model

    12  Pages

  9. C800

    4  Pages

  10. IR-R0A

    2  Pages

  11. R000

    4  Pages

  12. HN-EK

    2  Pages

  13. HN-EH

    2  Pages

  14. IR-HA

    2  Pages

  15. IR-TE

    2  Pages

  16. DP2000G

    4  Pages

  17. KP3000

    6  Pages

  18. KR3S

    6  Pages

  19. KR5100

    4  Pages

  20. IR-BZ

    2  Pages

  21. MILA-C5000PN

    4  Pages

  22. KR3000

    6  Pages

  23. Solidpak NC

    6  Pages

  24. Data Scanner

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.