The IR-CZ Series comprises infrared temperature sensors designed for industrial use, featuring a chopper-less design and semiconductor laser targeting to enable precise, non-contact temperature measurements.
High accuracy is achieved with resolution down to 0.015% of the measured value and sensitivity at 0.9μm wavelength. Accuracy depends on temperature range and diaphragm size, with specific calibrations for ranges such as 200-2000°C and 300-3500°C.
Detailed mechanical drawings and dimensions are provided for sensor mounting, diaphragm sizes, and air inlet ports to ensure proper installation and alignment.
| Parameter | Value/Range | Notes |
|---|---|---|
| Temperature Range | -10°C to 3500°C | Depends on diaphragm and model |
| Diaphragm Sizes | φ7mm, φ10mm, φ20mm, φ30mm | Controls measurement spot size |
| Output Signal | 4-20mA DC | Analog temperature output |
| Laser Targeting | Semiconductor laser ≤1mW, 645nm | Class 2 laser, no viewfinder |
| Alarm Output | Open collector 30V DC, max 50mA | High/low alarms, error signals |
| Emissivity | Remote adjustable or automatic | Critical for measurement accuracy |
Regular inspection and cleaning of the sensor window and diaphragm are necessary to avoid errors caused by dust, sediment, or damage. The sensor includes self-diagnostic and dirty lens detection features to alert operators.
The IR-CZ Series sensors offer precise, non-contact temperature measurement suitable for harsh industrial environments. Optimal performance depends on correct diaphragm and temperature range selection, regular maintenance, and use of integrated laser targeting and alarm functions.
300 with field diaphragm φ10mm 200 with field diaphragm φ10mm 300 with field diaphragm φ10mm 300 with field diaphragm φ10mm 300 with field diaphragm φ10mm 200 with field diaphragm φ 200 with field diaphragm φ 200 with field diaphragm φ
Open the catalog to page 1IR-CZ SERIES ,.μm) uses a chopper-less structure
Open the catalog to page 2IR-CZ SERIES C / C or 0.015% / C of measured value whichever larger φ20mm or φ10mm with field diaphragm
Open the catalog to page 4Sediment at furnace hole Window glass ! Temperature output 4-20mA Lack of view alarm output Dust / particles Furnace wall Analog input (Connector type only) Input signal: 4 to 20mA DC Selectable from emissivity remote setup or automatic emissivity calculation Contact input (Connector type only) 1 point: Peak hold reset or Sample hold or Laser on/off Dry contact or Open collector Contact output (Connector type only) 2 points: High (low) alarm or Error signal (self-diagnostic) or Dirty lens detection (2-colour model) Open collector 30V DC, Max. 50mA Laser targeting Built-in semiconductor laser...
Open the catalog to page 5IR-CZ SERIES "#" ■ The soft protective case IR-ZZCS is an exclusive accessory for the IR-CZ series to protect the thermometer from smoke, dust, etc at the installation site. This unit provides air-purge to remove smoke and dust for keeping the lens clean. Use clean instrumentation dried air. (Common use for connector type and terminal type) ■ The hard protective case IR-ZCCHT is an exclusive accessory for the IR-CZ series to protect the thermometer from high-temperature, humidity, smoke, dust, fume, etc. This unit provides air-purge and water-cooling to operate the thermometer properly in harsh...
Open the catalog to page 6Cleaning plug
Open the catalog to page 74 Pages
2 Pages
4 Pages
2 Pages
8 Pages
14 Pages
4 Pages
6 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
6 Pages
2 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
12 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
2 Pages
6 Pages
8 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages