Hybrid Recorder
6Pages

{{requestButtons}}

Catalog excerpts

Hybrid Recorder - 1

KL4000 SERIES 100mm chart DOT-PRINTING HYBRID RECORDER KL4000 Series hybrid recorders realize simple and easy operation as analog recorders. Not only can each measured value be read from the custom made analog scale plate which incorporates input type and measurement value input, but a comprehensive LED display also enables precise digital measurements to be taken by the user. FEATURES Dual displays for accuracy and simplicity Measured value can be read at a glance, directly from the triple scale analog display plate while a digital display clearly indicates measured values. Ready to run immediately after Power ON As the recorders are pre-set to meet individual customer specifications and precise application requirements, the unit starts indicating and recording as soon as they are Power ON. Front section USB port provided Connect with PC by mini-USB cable.* By attached setting software, you can set or change the parameter by PC. *Purchase commercialized product separetely. Corresponds to custom-made In addition to easy to use features, we will correspond to adding various devices and special features according to user’s requirement. Packaged Software attached . By Data acquisition software, the use of application is expands from recording/management to information processing. *Optional communication interface is required. Parameter setting software can manage the setting information on PC. Input signal 1 : Thermocouple/DC voltage single range 2 : Resistance thermometer single range 5 : Thermocouple/DC voltage individual range 6 : Resistance thermometer/ thermocouple/DC voltage individual range Input point 06 : 6 points Communication interface (option) N : None R : RS232C A : RS422A/RS485 Alarm output / remote contacts (option) 0 : None 2 : Mechanical relay 2 points (‘a’ contact) 4 : Mechanical relay 4 points (‘c’ contact) + remote contact 5 points A : Mechanical relay 6 points (‘a’ contact) + remote contact 5 points Power supply A : 100-240V AC

Open the catalog to page 1
Hybrid Recorder - 2

KL4000 SERIES NAME Pointer Scale plate Display CH.No. Display DATA Operation/Setting Key Engineering port (USB communication connector) Display and operation keys [Display] CH.No. Channel number of analog indication and data display (data display only for one-point continuous display) * DATA Data or time display* *Set contents are displayed while in [Setting mode]. Green light lights during recording. Operation of recording ON/OFF is done by REC key. Flashes when chart end. ALM Red light blinks during alarm activation. Feeds chart at a speed of 600mm/min while this key is pressed. Switches...

Open the catalog to page 2
Hybrid Recorder - 3

RECORDING EXAMPLE Periodic data printing and fixed time printing Prints data(time, scale, chart speed periodic, setting change mark and printing of time line) on trace printing at arbitrary set intervals. Chart speed Scale Scale Time Time line Trace printing Data printing When the latest data is required, trace printing will stop and record. Digital recording Trace printing Alarm activation and reset printing When an alarm activation and reset occurred, its time, CH No, alarm type and level are printed. Alarm reset time Alarm reset CH No. Level (alarm points No.) Time printing Level (alarm...

Open the catalog to page 3
Hybrid Recorder - 4

KL4000 SERIES INPUT SPECIFICATIONS DISPLAY AND INDICATION SPECIFICATIONS Measuring points: 6 Input types: DC voltage --- ± ± ± ± ± DC current --- Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately) Thermocouple --K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel Resistance thermometer --Pt100, old Pt100, JPt100, Pt50, Pt-Co Accuracy ratings: Refer to the tables of measurement range, accuracy ratings and display resolution Measuring interval:5sec./6points Reference junction compensation accuracy: At ambient temperature:23 ±10 K, E, J,...

Open the catalog to page 4
Hybrid Recorder - 5

MEASURING RANGES/ACCURACY RATING/DISPLAY RESOLUTION Input type DC voltage L W-WRe26 WRe5-WRe26 NiMo-Ni Platinel PtRh40-PtRh20 CR-AuFe Accuracy ratings Display resolution Note: The accuracy ratings are converted into the measuring range under reference condition. Thermocouple input does not contain reference junction compensation accuracy. K, E, J, T, R, S, B, N : IEC584(1977, 1982), JIS C 1602-1995, JIS C 1605-1995 W-WRe26, NiMo-Ni, Platinel , PtRh40-PtRh20, CR-AuFe, Au/Pt : ASTM E1751 WRe5-WRe26 : ASTM E988 U, L : DIN43710-1985 Pt100 : IEC751(1995), JIS C 1604-1997 Old Pt100 :...

Open the catalog to page 5
Hybrid Recorder - 6

APPLICATION SOFTWARE (standard attached) Data Acquisition Software You can acquire data easily to your PC. Parameter Setting Software *Optional communication interface required Control the setting information at PC by using communication interface or USB port (standard equipped) List Data Screen Trend Data Screen TERMINAL ARRANGEMENT Alarm relay output(6 points ‘a’ contact) + remote contacts and communication interface Communication terminal 1 Power/protective conductive terminals Remote contact terminals (option) Alarm output terminals (option) N.O terminal Measurement input terminals...

Open the catalog to page 6

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages