SE3000 series scanning units are designed for data logging with a personal computer. The basic unit with 6 input points can be connected to 7 sub units (6 input points / sub unit) and maximum 48 analog data can be collected. Two soft ware packages, “KIDS” for data logging and “PASS” for parameter programming, are available. This unit can be used for input point extension of CHINO’s BR series Graphic Recorders. ■Features MODBUS protocol Three kinds of serial communications, RS-232C, RS-422A and RS-485, are standard. The communications protocol is MODBUS for easy system configurations and any specific communications software package is not required. Data logging software package Data can be managed by the data logging software package “KIDS” (separate purchase required) on a personal computer. The logged data can be utilized by worksheet applications. Parameter programming software package Through an engineering port, parameters can be easily set up by the parameter programming software package “PASS” (separate purchase required) from a personal computer. Universal input 10 dc voltage/current inputs, 36 thermocouple lnputs and 11 resistance thermometer inputs are standard, and ranges can be set to each channel 1 ndependently.
Open the catalog to page 1■ Input specifications Measuring point: I nput kinds: Accuracy ratings: Measuring interval (The above error is added to the accuracy ratings for the internal reference junction compensation.) The sensor disconnection is detected for the thermocouple input and the resistance thermometer input. Burnout enable or disable can be selected in each input. I Display specifications (Basic unit) Status display Display element: Display content: Circle type red LED 3 pieces, green LED 1 piece Run status Communications status Data display (option): Normal Receiving Transmitting Alarm status Activating 5-digit...
Open the catalog to page 2ptumwin ainuc*™ Input kind Basic unit (6 input points) SE310 □ -000 Display unit (option) 0: Not provided 1: Provided Sub unit (6 input points) SE3211-000 ■ Parameter programming software package “PASS” (separate purchase required) Ver. 4.0 or later The parameter programming software package "PASS” is for programming parameters of the SE3000. Input kids, range/scale, alarm and burnout Temperature unit, alarm deadband Storing programmed parameters -to a file (FD, HD), replaying and printing ■ Data logging software package “KIDS” (separate purchase required) Ver. 4.0 or later The data logging software...
Open the catalog to page 3I Terminal board The figure shown below is the terminal board for the connection with 3 sets of the sub unit (total 24 input points) and with the display unit (option). Sub unit —rr Communications RS-232C SD RS-232C RD RS-232C SG RS-422A SDA RS-422A SDB RS-422A RDA RS-422A RDB Power/Ground 100 to 240VAC L 50/60Hz H Protective conductor terminal Input terminals For thermocouple and dc voltage inputs ... (+) (-) For resistance thermometer input . (A) (B) ■ Terminal board For the connection of 1 basic unit and 3 sub units (total 24 input points), and with the display unit [Basic unit] MODBUS is...
Open the catalog to page 48 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
14 Pages
4 Pages
6 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
6 Pages
2 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
12 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
2 Pages
6 Pages
8 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages