Group: Industrial Process Instrumentation
Catalog excerpts
PERFORMANCE SPECVICATNN EL3000 series is a dot printing type analog recorder sized 144x144mm with 100mm width chart. The unit starts recording as soon as the power supply and input are connected and it is also easy to operate. Scale plate, input range and function of the recorder can be selected for various purpose and applications as many kinds of options are prepared. ■FEATURES •Universal power supply Universal power supply with voltage range of 100 to 240V AC (50/60Hz) is applied. •Linear temperature scale Temperature scale of thermocouple and resistance thermometer input is a linear scale that is excellent in reading indication value. •Standard 6 chart speeds 6 chart speeds (5,10,20,40,80,160mm/h) are switchable as standard. 5 chart speed and hour/minute change are prepared as option. •Alarm setting (common alarm) as standard Higher and lower limit alarm can be programmed for every point. Alarm value is easy to be programmed by pointer location. You can check the alarm by front LED lighting. Alarm output is prepared as option. •CE marking The EL recorder is conformed to the rules of safety standards of CE. •Unit structure and light-weight Light-weight (50% of the previous unit weight) was realized by easy maintenance unit structure. •Employing removable type terminal board Employing easy connecting removable type terminal board. ■ MODELS EL3D^-^^ Input point 1 : 1 point 2 : 2 points 3 : 3 points 6 : 6 points Input signals 5 : Thermocouple/DC voltage 7 : Resistance thermometer Thermocouple with burnout/ DC voltage Built-in voltage divider input (option)*1 Input and scale plate(option)*2 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input, and built-in voltage divider) + standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input, and built-in voltage divider) + Non-standard scale plate Alarm output 0 : None 1 : 2 alarm outputs Chart speed and burnout*3 0 : Standard 6-speed + burnout disabled 1 : Standard 6-speed + up-scale burnout 2 : Standard 6-speed + down-scale burnout A : Standard 5-speed hour / minute change + burnout disabled B : Standard 5-speed hour / minute change + up-scale burnout C : Standard 5-speed hour / minute change + down-scale burnout *1 : Optional built-in voltage divider and thermocouple / resistance thermometer burnout input is only type "7". *2 : Double scale is available. Input and scale selection are needed for non-standard input and non-standard scale plate. *3 : Burnout on all channels is programmed together for thermocouple / resistance thermometer input.
Open the catalog to page 1■ INPUT SPECIFICATIONS ■OPERATION / PROGRAMMING SPECIFICATIONS Measurement point: Reference range and types: 1,2,3 and 6 points DC voltage — ±13.8mV, ±27.6mV, ±69mV, 200mV, ±500mV,±2V, ±5V Built-in voltage divider; ±10V, ±25V, ±50V DC current --- External installation of shunt resistor(250Q) is applied (option) Thermocouples --- K, E, J, T, R, and B (option) Resistance thermometer --- Pt100(1997) (Measured current; 1mA) * Linear scale for thermocouple and resistance thermometer Single scale (standard), double scale (option) ±0.5% of input span (except for some input under standard operating...
Open the catalog to page 2PERFORMANCE SPECIFICATION •Standard range and minimum width of scale Options Input type •Standard input and chart paper Nos. Input type Minimum scales Input code K,E,J,T,R : IEC584,JIS C 1602-1995 Pt100 : IEC751.JIS C 1604-1997 Programmable minimum width of scale: DC voltage — 10mV DC width or more Thermocouple — K: 250°C width or more E,J,T: 200°C width or more R: 800°C width or more Resistance thermometer — 100°C width or more •Exceptions of accuracy ratings Input types Note) The accuracy ratings are converted into the measuring range
Open the catalog to page 3■TERMINAL BOARD Alarm output terminals (option) (+)(A)Terminals (−)(B)Terminals (B)Terminals Resistance thermometer Power/protective conductor terminals Measurement input terminals ●Panel cutout ●Minimum clearance for plural installation 200 144 Specifications subject to change without notice. Printed in Japan (I) 2014. 4 32-8 KUMANO-CHO,ITABASHI-KU,TOKYO 173-8632 Telephone : +81-3-3956-2171 Facsimile : +81-3-3956-0915 E-mail : inte
Open the catalog to page 4All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages