Group: Industrial Process Instrumentation
Catalog excerpts
DIGITAL PROGRAM SETTER The KP3000 series is a 96x96mm digital program setter with the analog output accuracy of ±0.1% and maximum 30 program patterns (maximum 19 steps/ Output signal can be specified from analog output type and digital output type. By combination with a digital indication controller with digital input, the configuration of low cost program control system is enabled. Settings of maximum 19 steps per pattern and maximum 30 sets of patterns are enabled. Repeating of a whole pro- gram pattern, linking of program patterns and repeating of a specific step in a program pattern are enabled, too. ►Analog output type and digital output type Output of setting unit is selected from high accuracy (0.1 %FS) analog output type and digital output type which has no setting error by using communications function. ►Communications 2-port type provided Models with 2 communications ports are available. In addi- tion, speeding up and highly-functionalization of communi- cations have been realized. For example, you can use 1 port for high order communications with a personal comput- er and another port for the communications remote (digital remote) function. The communications protocol can be arbi- trarily selected from [MODBUS] and [PRIVATE]. In the digital output type, however, 1-port type of communi- cations is only available. When the digital input (Dl) or the digital output (DO) is ad- ded, arbitrarily-allocation for assigning functions to those DI/DO's is enabled. It is the function enabling allocations such as [External drive input] to DM to DI3 and [Pattern se- ►Conforming to international safety standards and Euro- The controller is conformity with European directives (CE), The controller is an environmental consideration product which does not contain directed hazardous substances Output signal Analog output (Others) -Case color Panel sealing and terminal cover* 3: IP54 panel sealing + Terminal cover Power supply voltage *1 It can be selected when the control signal is 1 or 7 only. *2 The digital input is 1 point for the control signal of 1 or 7. *3 It can be selected when the control signal is 2, 4, 5, 6 or 7 only. *4 It can be selected when the control signal is 2, 4, 5 or 6 only. Note: For options common to 1st zone, 2nd zone and 3rd zone, assign them in order of [P] and [T] from 3rd zone first
Open the catalog to page 1Operation status (RUN) indication Lights in operation. Program remote (REM) indication Lights when operation is executed by digital input. Executing step number (STP) indication The step No. being executed is indicated. Function (FNC) operation indication Lights when the function key is operated. RESET indication Lights when operation is cancelled and returns to the start point. Operation stop (STOP) indication Lights in the state of operation stop. 15. Set value (SV) indication 16. Time signal (TS1 to TS8) indication FNC key With the operation screen displayed, pressing it puts the...
Open the catalog to page 2OUTPUT SPECIFICATIONS Output signal: Analog output 4 to 20mA, 0 to 1V, 0 to 10V Digital output RS422A, RS485 Accuracy rating: ±0.1% of full scale Output updating cycle: Analog output Approximately 0.1 seconds Digital output Approximately 1 second Resolution: Approximately 1/30000 Output impedance:Voltage output Approximately 10 Load resistance: Current output 400 or less Voltage output 50k or more DISPLAY SPECIFICATIONS Upper display: Lower display: LED LCD (with back light) 108 x 24 dots GENERAL SPECIFICATIONS No. of program patterns: 30 patterns Pattern repetition … Max.9999 times No. of...
Open the catalog to page 3OPTIONS Communications interface With RS232C, RS422A or RS485, the setting and measured values of the controller can be transmitted to a master CPU and various parameters can be set by the master CPU. Number of communications points: 2 points Communications type: RS232C, RS422A, RS485 Communication speed: 2400/4800/9600/19200/38400 bps Protocol: MODBUS (RTU), MODBUS (ASCII), PRIVATE Digital signal input The following switching is enabled by digital input signal. Input signal: No-voltage contact, open-collector signal External contact capacity: 5VDC 2mA Functions: 1. Selection of pattern No....
Open the catalog to page 4TERMINAL ARRANGEMENT Digital output Analog output (Voltage/current) Option terminals Digital output + Communications Communications RS232C Options common to each zone Based on combination with other options, assign the zone in the above order. R: Communications RS232C + 3 Digital inputs A: Communications RS422A + 1 Digital input S: Communications RS485 + 3 Digital inputs B: Communications RS232C + Communications RS232C + 1 Digital input C: Communications RS232C + Communications RS422A + 1 Digital input D: Communications RS232C + Communications RS485 + 1 Digital input E: Communications RS485...
Open the catalog to page 5ABOUT CRIMP STYLE TERMINALS 7 or less 3.7 or less Ring type Spade type *Use terminal with insulation EXTERNAL DIMENSIONS Terminal cover Mounting metal Closed mounting panel dimensions PANEL CUTOUT N: Number of mounted instruments Specifications subject to change without notice. Printed in Japan (I) 2010. 11 32-8 KUMANO-CHO,ITABASHI-KU,TOKYO 173-8632 Telephone : +81-3-3956-2171 Facsimile : +81-3-3956-0915 E-mail : inter@chino.co.jp Website : www.chino.co.jp/
Open the catalog to page 6All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages