Digital Indicating Controller PERFORMANCE SPECIFICATION © [DISPLAY]/[DSP] key: © [MODE] key : ®<,V,A Key : ® [ENT] key : ® Loader connector : LT 35A/37A series is digital indicating controller with indicating accuracy of ±0.2% and the control cycle of approximately 0.3 seconds. 3 types of auto tuning functions and overshoot suppression functions achieve superior control stability. Combination of internal computing function and enriched input and output option support various usage scenarios. Special loader software provides ease of setting operations and data acquisition. ■FEATURES •Compact design Short depth of instrument (case 65mm) saves the space of instrument and control board. •Universal input Input types is user-changeable from among thermocouple, resistance thermometer, DC voltage and DC current. •Outstanding controllability Control system can be selected from two-position control and PID control. It has overshoot suppression function and high-functional PID. •3 type of auto tuning Can be selected from normal, rapid-response, stable tuning on the control target. •Various input / output signal (optional) are available Current transformer input 2 points, event output 3 points (Max), remote signal input 4 points, communication interface (RS485). •Conformance to international safety standards CE marking, RoHS •Loader software is available Various parameter settings and data acquisition can be done easily using loader software (sold separately) . ■PARTS NAMES OF FUNCTIONS ® Upper display : Displays PV values (measuring temperature, etc.) or setting items. @ Lower display : Displays SP values (preset temperature, etc.) and other parameter set values. ® Status display lamp : MAN : Lights when MANUAL (manual mode) EV1 to EV3 : Lights when event outputs are ON. 01 to 02 : Lights when the control output is ON. 0 Multiple functions indicating lamp: User-settable max. 3 sets combination of condition and status as preferred functions (alarm, READY, etc.). Press 1 second or longer, then enters frequently used functions and operations set in advance. The function is disabled at factory default. Switch display in operation mode. Or back to operation mode from parameter setting mode. Switches the display. Used for incrementing numeric values and performing arithmetic shift operation. Starts to change settings and set value Connects to a personal computer by using USB loader cable. *1: Current transformer is sold separately. *2: 24 V AC/DC power supply can not be selected. *3: Non-conforming to CE, UL/cUL. *4: Event output are 2 types, specify models of 3 point (common) or 2 points (independent).
Open the catalog to page 1LT35A/37A Series Compact size Correspond to heat / cool control PV Heat SP Control output of heat or cool can be assigned to the output 1 and 2. PV and SP can also be assigned and used as transmission signal output. There are size 48x96mm and 96x96mm available. Depth is only 65mm, so it is space saving for any installation. Advanced controllability Overshoot suppression factor Small (SP) (SP) PV Overshoot suppression factor Large In addition to the conventional PID, “High-performance PID” is available which has unique algorithm aim to converge hunting quickly to decrease settling time. Easy-to-read...
Open the catalog to page 2PERFORMANCE SPECIFICATION ■ SPECIFICATIONS •Input specifications Input signal: Universal input (Thermocouple, Resistance Thermometer, DC voltage/current) Range type: Refer to a measuring range table Input sampling cycle: 300ms Accuracy rating: ±0.2%FS±1digit Reference junction compensation accuracy: ±0.5°C (at ambient temperature 23°C ± 2°C) •Control specifications Output type: ON-OFF pulse output type 1c 250V AC/ 30V DC 3A (resistance load) Current output type 0 to 20mA DC, 4 to 20 mA DC (It can be changed by the setting) SSR drive pulse output type 19V DC±15%, Internal resistance 820,...
Open the catalog to page 3PERFORMANCE SPECIFICATION ■ ACCESSORY ■TERMINAL BOARD Item Power supply Control output ON-OFF pulse Event output ■ ACCESSORY (Sold separately) Item Relay Individual contact Measurement input Current Voltage SSR driver pulse Current / SSR driver pulse Current Voltage Transmission signal output Remote signal input Terminal screw •Minimum clearance for plural installation Terminal screw •Minimum clearance for plural installation (48XN-4) +o'5 N : Nos. of mounting Specifications subject to change without notice. Printed in Japan (I) 2014. 12 CHINO CORPORATION 32-8 KUMANO-CHO,ITABASHI-KU,TOKYO 173-8632...
Open the catalog to page 48 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
14 Pages
4 Pages
6 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
6 Pages
2 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
12 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
2 Pages
6 Pages
8 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages