Group: Industrial Process Instrumentation
Catalog excerpts
DIGITAL INDICATING CONTROLLER LT110 SERIES LT110 series, 1/32 DIN size, miniature digital indicating controllers, feature all functions that are convenient in various control applications. The controllers are applicable to various equipment including semiconductor manufacturing equipment, electronic parts manufacturing equipment, food-processing machinery, packaging machinery, injection machine. FEATURES Small size, lightweight, short space Universal input consisted of 5 kinds of T/C input and 4 kinds of RTD input, and multi-input of 5 kinds of T/C input Optimum PID values are automatically calculated for accurate and stable control by PID auto-tuning. Various functions including sensor correction, setpoint lock, setpoint limit, control output OFF, and alarm action delay timer are built-in. The controllers conform to CE and the front panel is dust-proof and water-proof conforming to IP-65. Hysteresis: 0.1 to 100.0°C (2-position control only) Anti-reset windup: Automatic Control operation: Direct/reverse operation switching Output: On-off pulse type Output signal ……… On-off pulse conductive signal Contact rating ……. Resistive load 250VAC 3A Inductive load 250VAC 1A On-off pulse time … Approx. 1 to 120seconds variable Current output type Output signal ……… 4 to 20mADC Load resistance .….. 500Ω or less SSR drive pulse type Output signal ……… On-off pulse voltage signal At ON 12VDC ± (0 to +2V), Max 40mA On-off pulse cycle … Approx. 1 to 120 seconds variable Output limiter: 0 to 100% (–5 to 105% for current output type) 0A Size 1: 48 x 24mm Input signal 0: Universal input (with 1 event output) 1: Thermocouple multi- input Control output 1: On-off pulse type 3: Current output type 5: SSR drive pulse type Options (Available in universal input only) ALARM SPECIFICATIONS Alarm point: 1 point Temperature alarm type: Deviation high alarm, deviation low alarm Absolute value deviation high alarm, absolute value deviation low alarm Deviation high alarm with standby function Deviation low alarm with standby function Absolute value deviation high alarm with standby function Absolute value deviation low alarm with standby function Absolute value high alarm, absolute value low alarm Absolute value high alarm with standby function Absolute value low alarm with standby function Loop break alarm: Alarm activation when the control output is maximum or minimum and the process value does not vary more than a set band in a set time. Heater disconnection, sensor disconnection, control equipment failure Alarm time setting range: 0 to 200 minutes Alarm band: 0 to150°C or 0.0 to 150.0°C Alarm deadband: 0.1 to 100°C Alarm output: Open collector 24VDC 0.1A (maximum) 0: None 1: Setpoint change (DI) ... With 2 SVs and 1 DI 2: Heater disconnection (CT) … With current transformer Available in on-off pulse type and SSR drive pulse type only Power supply A: 100 to 240VAC (universal) SPECIFICATIONS INPUT SPECIFICATIONS Input signal: T/C … K, N, J, E, Platinel II RTD … Pt100, JPt100 Measuring range: Refer to the measuring range. Indication accuracy ratings: T/C…±0.3% of input span ± 1 digit or ±2°C, whichever is larger RTD…±0.2% of input span ± 1 digit Measuring unit: °C or °F Sampling time: Approx. 0.25 second Burnout: Upscale Allowable signal source resistance: T/C … 100Ω or less RTD … 10Ω or less (per wire) Measuring input shift (sensor correction): -100.0 to 100.0°C DISPLAY FUNCTION Display: 4-digit LED Display contents: PV or SV switching, Parameter item GENERAL SPECIFICATIONS Power voltage: 100 to 240VAC, 50/60Hz (universal) Working temperature: 0 to 50°C Working humidity: 35 to 85%RH (no dew condensation) Power consumption: Approx. 5VA Case: Non-flammable resin Color: Gray Installation: Flush panel installation Weight: Approx. 100g CONTROL SPECIFICATIONS Control cycle time: Approx. 0.25 second Control system: PID (2-position control enabled) Control setting accuracy ratings: Same as indication accuracy rating Auto-tuning: Standard (Manual setting of PID constants enabled) PID constants: P … 0 to Maximum value of each range I …. 0 to 3600 seconds D … 1 to 3600 seconds Pulse cycle: 1 to 120 seconds (Available in on-off pulse type and SSR pulse type only)
Open the catalog to page 1PERFORMANCE SPECIFICATION MEASURING RANGES Specifications subject to change without notice. Printed in Japan (I) 2002. 7 CHINO CORPORATION 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 E-mail: inter@chino.co.jp Website: http://www.chino.co.jp
Open the catalog to page 2All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages