Digital Indicating Controller DB2000
8Pages

{{requestButtons}}

Catalog excerpts

Digital Indicating Controller DB2000 - 1

DIGITAL INDICATING CONTROLLER The DB2000 series is a 96×96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. The configuration of highly functional system is enabled by various options including 2 transmission signal outputs, 2 communications ports and arbitrarily-allocation of digital inputs. FEATURES Large easy-to-view 5-digit display Process value (PV) and set value (SV) are displayed by large easy-to-view 5-digit display indicators. The resolution of 0.1°C is enabled for more than 1000°C. Highly-functional operation screen and settings screen The controller inherits the operation screen and the settings screen adopting the LCD (liquidcrystal-display) which has been familiarized for long time. Furthermore, the screens have become high-definition and highly sophisticated. READY function provided Although the DB2000 series is the constant value controller, switching to the state (READY) that any control is not wanted is enabled. In addition, the output value (MV) at READY can be set arbitrarily. Outstanding controllability Two types of PID algorithms, the position-type PID algorithm and the speed-type PID algorithm, have been installed. You can select the optimum PID algorithm for an object controlled. DI arbitrarily-allocation When the digital input (DI) is added, arbitrarily-allocation for assigning functions to those DI's is enabled. It is the function enabling allocations such as [READY/RUN] to DI1 and [Manual output operation/Automatic output operation] to DI2. Versatile control functions provided Versatile control functions, such as the automatic PID system, which executes control by PID parameters preset at every SV sections, and selection of the 2-output control system from PID system and split system for 2-output types, are available. Communications 2-port type provided Models with 2 communications ports are available. In addition, speeding up and highly-functionalization of communications have been realized. For example, you can use 1 port for high order communications with a personal computer and another port for the communications remote (digital remote) function. The communications protocol can be arbitrarily selected from [MODBUS] and [PRIVATE]. Transmission signal 2-output type available 2 types of transmission signal output, the high-precision type (0.1% of full scale) and the general type (0.3% of full scale), are available. Transmission signal 2-output types with these 2 transmission signal outputs and models with transmitter power supply are available. Heater disconnection alarm The heater disconnection alarm can be added to ON-OFF pulse types or SSR drive pulse types only. By connecting the designated CT externally, the current value of heater is measured and can be indicated on the operation screen. Other functions Various functions including multiple auto-tuning, timer function using the digital input (DI), control loop abnormality alarm and user calibration are built-in. Conforming to international safety standards and European directives (CE) The controller is in conformity with European directives (CE), and is UL and c-UL approved. Conforming to RoHS The controller is an environmental consideration product which does not contain directed hazardous substances such as lead, etc.

Open the catalog to page 1
Digital Indicating Controller DB2000 - 2

-Input signal -Control mode (Output No. 1) 1: ON-OFF pulse type PID 2: ON-OFF servo type PID (Standard load specification) 3: Current output type PID 5: SSR drive pulse type PID 6: Voltage output type PID 8: ON-OFF servo type PID (Very light load specification) -Control mode (Output No.2) * 5: Remote signal input (4 - 20mA) 6: Remote signal input (0 - 1V) 7: Remote signal input (0 - 10V) 8: Remote signal input (Others) 9: Heater disconnection alarm *2 M:4 Digital inputs + Heater disconnection alarm *2 Transmission signal output (High-precision type: 4 - 20mA) Transmission signal output...

Open the catalog to page 2
Digital Indicating Controller DB2000 - 3

PERFORMANCE SPECIFICATION NAMES OF VARIOUS PARTS 1. Operation status (RUN) indication 2. Slope (SLOPE) indication Lights in slope operation of SV. 3. Ready state (READY) indication Lights during idling. 4. Alarm-standby (WAIT) indication Lights in alarm-standby status or when alarm is 6. Executing set value number (NO.) indication Lights when sampling of input is abnormal. 8. Auto-tuning operation (AT) indication Lights in auto-tuning operation. 9. Manual operation (MAN1/MAN2) indication Lights when the output No.1 or No. 2 is in manual output operation. 16. Process value (PV) indication...

Open the catalog to page 3
Digital Indicating Controller DB2000 - 4

CONTROL SPECIFICATIONS INPUT SPECIFICATIONS Input type: Thermocouple B, R, S, K, E, J, T, N, WRe5-WRe26, W-WRe26, NiMo-Ni, CR-AuFe, PR5-20, PtRh40-PtRh20, Platinel II, U, L DC voltage ±10mV, ±20mV, ±50mV, ±100mV, ±5V, ±10V DC current 0 to 20mA Resistance thermometer Pt100, JPt100, Old Pt100, JPt50, Pt-Co Measuring range: Thermocouple 28 ranges DC voltage 6 ranges, Direct current 1 range Resistance thermometer 14 ranges *For details, refer to [Measuring ranges]. Accuracy rating: ±0.1% of measuring range ± 1 digit *For details, refer to [Detailed specifications of accuracy ratings]. Reference...

Open the catalog to page 4
Digital Indicating Controller DB2000 - 5

ALARM SPECIFICATIONS Number of alarm points: 4 points Alarm types: Absolute value alarm, deviation alarm, absolute value deviation alarm, setting value alarm, output value alarm, control loop abnormality alarm, FAIL, timer Output signal: Relay output signal (a contact) 1 common terminal for AL1 and AL2, 1 common terminal for AL3 and AL4 Contact capacity Resistive load 100 to 240VAC 30VDC 3A or less Inductive load 100 to 240VAC 30VDC 1.5A or less Smallest load 5VDC 10mA or more GENERAL SPECIFICATIONS Rated power voltage: General power supply specifications 100 to 240VAC 24V Power supply...

Open the catalog to page 5
Digital Indicating Controller DB2000 - 6

• Transmission signal output Output a signal corresponding to set value (SV), process value (PV), Output signal: Output accuracy: 4 - 20mA (Load resistance 400Q or less) 0 - 1V (Output resistance Approx. 10fi, Load 0 - 10V (Output resistance Approx.10Q, Load High-precision type ±0.1 % of full scale General type ±0.3% of full scale • Transmitter power supply Maximum current capacity: • Remote signal input By using extermal contacts, switching of remote mode and local mode is enabled. With the remote mode, the setting of SV is enabled by remote Input signal: Input accuracy: Remote signal...

Open the catalog to page 6

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages