FIELD DATA SCANNING UNIT SE3000 SERIES SE3000 series scanning units are designed for data logging with a personal computer. The basic unit with 6 input points can be connected to 7 sub units (6 input points / sub unit) and maximum 48 analog data can be collected. Two soft ware packages, “KIDS” for data logging and “PASS” for parameter programming, are available. This unit can be used for input point extension of CHINO’s BR series Graphic Recorders. Features MODBUS protocol Three kinds of serial communications, RS-232C, RS-422A and RS-485, are standard. The communications protocol is MODBUS for easy system configurations and any specific communications software package is not required. Data logging software package Data can be managed by the data logging software package “KIDS” (separate purchase required) on a personal computer. The logged data can be utilized by worksheet applications. SE3000 Program display unit System configuration Parameter programming software package Through an engineering port, parameters can be easily set up by the parameter programming software package “PASS” (separate purchase required) from a personal computer. [KIDS] Up to 5 sets or Up to 100 channels Universal input 10 dc voltage/current inputs, 36 thermocouple inputs and 11 resistance thermometer inputs are standard, and ranges can be set to each channel independently. Up to 48 points including temperature, pressure and flow Up to 48 points including temperature, pressure and flow
Open the catalog to page 1Input specifications Measuring point: Basic unit 6 points, sub unit 6 points/unit Up to 7 sub units can be connected to one basic unit. (Up to 48 points) Input kinds: Universal input (dc voltage, dc current, thermocouple, resistance thermometer) Accuracy ratings: Refer to the table of measuring ranges. Measuring interval: 6-point/1 second, 12-point/2 seconds, 18-point/3 seconds, 24-point/4 seconds, 30-point/5 seconds, 36-point/6 seconds, 42-point/7 seconds, 48-point/8 seconds Reference junction compensation accuracy: K, E, J, T, N, Platinel ….. Lower than ±0.5ºC R, S, Ni-NiMo, AuFe-Cr, WWRe5-26,...
Open the catalog to page 2General specifications Input kind Measuring range Basic unit (6 input points) SE310 -000 Display unit (option) 0: Not provided 1: Provided Sub unit (6 input points) SE3211-000 Parameter programming software package “PASS” (separate purchase required) Ver. 4.0 or later The parameter programming software package “PASS” is for programming parameters of the SE3000. Programming Channel parameters Storing programmed parameters to a file (FD, HD), replaying and printing “KIDS” (separate purchase required) Ver. 4.0 or later The data logging software package “KIDS” is for logging the data measured by...
Open the catalog to page 3Terminal board The figure shown below is the terminal board for the connection with 3 sets of the sub unit (total 24 input points) and with the display unit (option). Sub unit (A), (+) Communications RS-232C SD RS-232C RD RS-232C SG RS-422A SDA RS-422A SDB RS-422A RDA RS-422A RDB Power/Ground 100 to 240VAC L 50/60Hz H Protective conductor terminal Basic unit (B) For thermocouple and dc voltage inputs … (+) (-) For resistance thermometer input … (A) (B) Input terminals Terminal board For the connection of 1 basic unit and 3 sub units (total 24 input points), and with the display unit * MODBUS...
Open the catalog to page 48 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
14 Pages
4 Pages
6 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
6 Pages
2 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
12 Pages
6 Pages
6 Pages
4 Pages
6 Pages
6 Pages
6 Pages
2 Pages
6 Pages
8 Pages
6 Pages
6 Pages
4 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages