1. Catalogs
  2. China Shenzhen Jiwei Automations Ltd.
  3. Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement

Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement

Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement

Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement

Product catalog summary
Introduction
Jiwei's Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output is designed for measuring liquid levels in the production of ethylene glycol from coal. Ethylene glycol is used in various industrial applications, including as a raw material for polyester fibers and antifreeze formulations.

Risk Factors in Production
1. Toxicity: The production involves toxic substances like methanol and ethylene glycol, which can irritate eyes, skin, and mucosa.
2. High Temperature: The process involves high temperatures, with dimethyl oxalate produced at 120-145°C and ethylene glycol at 170-210°C. Sensors must withstand temperatures above 100°C.
3. Flammability and Explosiveness: The medium is hazardous, requiring sensors with explosion-proof capabilities.

Features of Jiwei Ring-11 Switch
The Jiwei Ring-11 switch offers NAMUR output, which is safer for explosive environments due to its lower current and voltage requirements. It is certified for intrinsic safety and flameproof enclosure explosion protection. The switch is highly sensitive, resistant to disturbances, and can operate in high-temperature environments up to 250°C.

Advantages
- Four output options: relay, two-wire, NAMUR, and transistor.
- High sensitivity with a measurable medium density as low as 0.5g/cm³.
- Resistant to foam, bubbles, viscosity, and vibration.
- Made of 316L with optional anti-corrosion coatings.
- High-voltage protection to prevent leakage of corrosive liquids.

Certification and Client Feedback
The Jiwei Ring-11 switch has SIL and Intrinsically Safe certifications. A client in Jiangsu Lianyungang replaced all original switches with Jiwei Ring-11, reporting excellent performance over a year and plans to use them in future projects.
See more

Catalog excerpts

Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement-1

Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement Ethylene glycol is a chemical commonly used in many commercial and industrial applications including antifreeze and coolant. Ethylene glycol is an organic compound with the formula (CH2OH)2. It is mainly used for two purposes, as a raw material in the manufacture of polyester fibers and for antifreeze formulations. It is an odorless, colorless, sweet-tasting, viscous liquid. At present, there are three main processes for the preparation of ethylene glycol from coal-based, which are direct method, olefin method and oxalate method. Among them, oxalate method uses coal as raw material, and the so-called "coal to ethylene glycol" also refers to this process. Jiwei’s client, a clean energy company in Jiangsu Lianyungang has been using liquid level switch for level measurement in coal powder pressurized convey device of ethylene glycol production, which requires the sensors have high performance. Three Risk Factors in Coal to Ethylene Glycol Production 1. Toxic Methanol, sodium nitrite, dimethyl oxalate and ethylene glycol produced in coal to ethylene glycol production are toxic and harmful substances. They have strong irritation to eyes, skin and mucosa. 深圳计为自

 Open the catalog to page 1
Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement-2

2. High Temperature In coal to ethylene glycol production, dimethyl oxalate is produced in the synthesis reactor at 120 ~ 145 ℃, and ethylene glycol is produced in the hydrogenation reactor at 170 ~ 210 ℃. As the high pressure steam temperature is up to 500 ℃, and the steam temperature used in the heat exchanger and distillation column in the whole reaction zone is above 100 ℃, the sensors should withstand the temperature above 100 ℃. 3. Inflammable and Explosive The medium in ethylene glycol production is inflammable, explosive and hazardous, so requires high performance sensors with explosion-proof...

 Open the catalog to page 2
Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement-3

Advantages of Jiwei Ring-11 Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output ● Four optional outputs: relay output, two-wire system, NAMUR and transistor. ● Certified for both Intrinsic Safety and Flameproof Enclosure explosion protection. ● High sensitivity due to the precisely pre-adjusted harmonic resonant frequency of fork, the lowest measurable medium density can be as low as 0.5g/cm³. ● With strong disturbance resistance ability, not influenced by foam, bubbles, viscosity, vibration and other liquid characteristics. ● Tines are made of 316L, can be lined with anti-corrosion...

 Open the catalog to page 3
Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output for Coal to Ethylene Glycol Liquid Level Measurement-4

SIL Certificate & Intrinsically Safe Certificate of Jiwei Ring-11 Liquid Level Switch After test trial, the client replaced all the original liquid level switches to Jiwei Ring-11 Intrinsically Safe Tuning Fork Liquid Level Switch with NAMUR Output. The client also feedback that all the sensors have been running well beyond expectations for nearly a year since the installation, and in the new phase II project he will definitely use Ring-11 tuning fork level switches again.

 Open the catalog to page 4

All China Shenzhen Jiwei Automations Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.