Catalog excerpts
SCHEMTRAC PARTICLE COUNTER SENSOR The PC3 Particle Counter Sensor is an essential tool for municipal and industrial water treatment applications including filter performance monitoring, protecting RO membranes from colloidal fouling, and virtually any application where there is a concern of potential contamination in a clean liquid. The PC3 offers an excellent addition or alternative to other traditional measurements like turbidity (NTU) and Silt Density Index (SDI) testing. Particle counters are best known for their ability to detect when a filter has reached the end of its run well ahead of any impact to NTU readings. The more compact PC3 Particle Counter brings all the great features of Chemtrac's PC3400 model to the HydroACT family of analyzers. Customers can connect multiple sensors to the HydroACT analyzer, or mix and match the PC3 with other measurements like pH, chlorine, and UV254 for organics monitoring. The PC3 allows the user to view up to 3 channels of data in multiple measurement formats including “Total ppb”, “Total Counts”, and counts or ppb in individual size channels (e.g. 2 to 5 micron, 5 to 10 micron, etc.). Full integration between the sensor and analyzer means all sensor settings, including user-friendly calibration features, can be accessed from the HydroACT's user interface. Contact Chemtrac to discuss your application and let us find the right solution for you. STANDARD FEATURES • Counts particles in liquid from 2-750 microns • Sizes particles from 2-100 microns • Up to 3 user programmable size ranges • Reports total counts, cnts/mL, or cnts/100mL • User-friendly, menu driven calibration • Laser & cell condition readout (0-100%) • External sensor with sapphire optics • Available with HydroACT analyzer models HA2, HA4, and HA8 BENEFITS • Provides a reliable and accurate measurement of particles down to low ppt levels • Advanced firmware and menu functions eliminates need for external software to perform setup and calibration • User-friendly calibration routine makes the process fast and simple, and lowers maintenance cost • External sensor is easy to clean and water is kept away from electronics Water Treatment Boiler/Condensate Wastewater Treatment Parts Washing Reverse Osmosis Pretreatment Food & Beverage Membrane Filtration Pharmaceutical Particle Detection
Open the catalog to page 1Laser Type Solid-state laser diode (780nm) Cell Material Nituff coated aluminum PEEK plastic (optional) Viewing Windows Sapphire Detection Range 2-750 microns Sizing Range 2-100 microns Analog Output Type 4-20mA Flow Rate 75 mL/min Resolution Better than 10% at 10 micron (ASTM-F658) Coincidence Limit 20,000 cnts/mL (2 micron) Signal to Noise Ratio Better than 3:1 Size Channels 3 user-selectable; each size channel counts as a parameter on HydroACT analyzers Alarms Sensor diagnostic, low cell condition Laser Diode Life MTBF 75,000 hours @ 55° C...
Open the catalog to page 2All Chemtrac catalogs and technical brochures
-
UVP1000
1 Pages
-
UVM5000
2 Pages
-
PC6
2 Pages
-
PC5000
2 Pages
-
PC4400
2 Pages
-
PC3400
2 Pages
-
HydroACT Series
2 Pages
-
HydroACT 600
2 Pages
-
HydroACT 600 & DuraTrac 3
2 Pages
-
HydroACT 600 & DuraTrac 4
2 Pages
-
LCA-01 / LCA-02 / LCA-03
2 Pages
-
Coagulation Control System
2 Pages
-
Biofilm Sensor
2 Pages
-
Zero Free Chlorine Probe
2 Pages
-
ECA2100 & ECAT2100
2 Pages
-
CCA3100
2 Pages
-
SCM2500 & SCC3500
2 Pages
-
PM2500
2 Pages
-
UV1
2 Pages
-
pH / ORP ANALYZER
2 Pages
-
PC 2400 PS Portable Sampler
2 Pages
-
Particle Counter
2 Pages
-
Turbidity Monitor
2 Pages
-
CHLORINE RESIDUAL ANALYZER
2 Pages