Standard Features: The HydroACT Reagentless Chlorine Analyzer includes an analyzer, a free or total chlorine sensor, a flow cell, one analog output, and one year of consumables. It offers accurate chlorine measurement with reduced pH dependency, no moving parts, and no reagents. It is suitable for reporting when used in compliance with EPA Method 334.0 and includes event logging.
Optional Features: The system can be expanded with additional sensor inputs and I/O, color display, data-logging with microSD card download, Modbus or PROFIBUS communications, and chemical feed control capability such as PID. It also offers pH compensation for free chlorine readings.
Benefits: The analyzer provides a lower total cost of ownership, easy setup and maintenance, and intuitive menu and programming functions.
Applications: It is applicable in water treatment for online disinfection monitoring and dosage control, cooling towers, swimming pools, paper machine system microbial control, Legionella control, and food washing.
Description: The HydroACT Reagentless Chlorine Analyzer enhances online disinfection monitoring reliability with industry-leading performance, compliance with EPA Method 334.0, reduced pH dependency, and no zero calibration requirement. It features membrane-covered Free and Total Chlorine sensors with no moving parts and minimal maintenance.
General Specifications: The chlorine sensor probe is a membrane-covered amperometric three-electrode system measuring free or total residual chlorine with various probe ranges and resolutions. It offers automatic temperature compensation, a pH range of 4-9 for free chlorine, and 4-12 for total chlorine. The sensor requires no zero-point adjustment and manual calibration using DPD.
Installation and Configuration: The HydroACT system supports various sensor options, power configurations, and output types. It includes user-configurable alarms and thresholds, optional chemical feed control, and communication options like Modbus and Profibus. Data logging is customizable, and the enclosure is ABS flame retardant with IP65, Nema 4X rating.
HydroACT Features: The system offers different configurations (HA2, HA4, HA8) with varying limits on sensors, analog outputs, relays, and digital inputs. Advanced control options, color display, data logging, and remote access are available as optional features.
See more

Catalog excerpts

HydroACT Residual Chlorine Analyzer-1

ECHEMTRAC RESIDUAL CHLORINE ANALYZER HydroACT DESCRIPTION The HydroACT Reagentless Chlorine Analyzer takes online disinfection monitoring to a new level of reliability by offering industry-leading performance, an excellent track record of EPA Method 334.0 compliance, reduced pH dependency, and no requirement for zero calibration. Chemtrac's line of membrane covered Free and Total Chlorine sensors have no moving parts, no bottles of reagent to change out monthly, and quarterly maintenance takes less than five minutes to perform. HydroACT offers a versatile solution to your disinfection monitoring needs with the flexibility to accept additional sensors, as well as offering expandable I/O and PID control loops. STANDARD FEATURES • Includes analyzer, free or total chlorine sensor, flow cell, 1 analog output, 1 year consumables • Accurate chlorine measurement with reduced pH dependency • No moving parts, no reagents • Suitable for reporting when used in compliance with EPA Method 334.0 • Event logging OPTIONAL FEATURES • Expandable sensor inputs and I/O • Color display and data-logging with microSD card download • Modbus or PROFIBUS communictions • Chemical feed control capability (e.g. PID) • pH compensation of free chlorine reading ENEFITS • Lower total cost of ownership • Easy set up and maintenance • Intuitive menu and programming functions APPLICATIONS Water Treatment • Online disinfection monitoring • Disinfection dosage control Cooling Towers Swimming Pools Paper Machine System Microbial Control Legionella Control Food Washing Residual Chlorine

 Open the catalog to page 1
HydroACT Residual Chlorine Analyzer-2

GENERAL SPECIFICATIONS HydroACT Reaqentless Chlorine Analyzer The HydroACT Chlorine Analyzer standard configuration includes version HA2 analyzer, 1 sensor (Free or Total Chlorine), 1 analog output, and 1 year consumables. Optional features include relays, digital inputs, digital comms, expanded number of sensor inputs and analog outputs, color display, and data download capability. Maximum I/O capabilities and certain features are specific to the different versions of HydroACT as detailed below. HydroACT Features Analog output limit* 2 4 8 Digital input limit* 4 8 16 Color...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.