Overview: The HydroACT 300 Residual Chlorine Analyzer by Chemtrac, Inc. is designed for measuring free chlorine, total chlorine, chlorine dioxide, and pH. It is suitable for compliance reporting according to USEPA Method 334.0. The device features a membrane-covered three-electrode amperometric sensor, reducing pH dependency and maintenance costs.
Standard Features:
  • Accepts up to three measurements including various chemical and physical parameters.
  • Membrane-covered three-electrode amperometric sensors for chlorine.
  • Automatic temperature compensation and event logging.
  • Provides up to three analog outputs, four relays, and two digital inputs.
  • Isolated inputs and outputs with pH compensation for free chlorine sensor.
  • Low flow detector and PID control capability.
  • Communication options include Modbus, Profibus, or HART.
Optional Features: Additional sensor options for ozone, ORP, DO, conductivity, and more.
Benefits:
  • No reagents or moving parts, reducing maintenance.
  • Easy setup and intuitive programming.
  • Low purchase and ownership cost.
Applications: Suitable for water treatment, swimming pools, microbial control in paper machines, Legionella control, and food washing.
Technical Specifications:
  • Power options: 100-240 VAC or 12 VDC.
  • Display: LCD Backlit 128x64 graphical.
  • Sensor inputs: Up to 3, with specific requirements for pH with Temp probe.
  • 4-20mA outputs: Up to 3, with PID option utilizing 1 output.
  • Relays: Up to 4, with specific voltage and current ratings.
  • Enclosure: Nema 4X / IP65.
  • Dimensions and weight: 7.6” W x 6.3” H x 4.1” D, 2.2 lbs.
Chlorine Sensor Probe:
  • Type: Membrane-covered amperometric three-electrode system.
  • Probe ranges: Various mg/L options for free and total chlorine.
  • Temperature range: > 41° up to < 113° F.
  • pH range: pH 4 - pH 9 (Free), pH 4 - pH 12 (Total).
  • Calibration: Manual using DPD.
Chlorine Dioxide Sensor Probe:
  • Type: Membrane-covered amperometric two-electrode system.
  • Probe ranges: Various mg/L options.
  • Temperature range: > 41° up to 122° F.
  • pH range: pH 1 - pH 11.
  • Calibration: Manual using analytic determination.
pH with Temperature Sensor Probe:
  • Type: Combined reference and measuring electrode.
  • pH range: 0-14.
  • Temperature range: 32° - 212° F.
  • Estimated life: 12 - 24 months, application dependent.
Additional Information: The analyzer is not suitable for measuring or controlling dechlorination and recommends maintaining a free chlorine residual of at least 0.10 ppm.
See more

Catalog excerpts

HydroACT 300 - Residual Chlorine Analyzer-1

RESIDUAL CHLORINE ANALYZER HydroACT 300 · Capable of accepting up to three measurements including: Free Chlorine, “Zero” Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone, pH & Temp, ORP, TSS/NTU, DO, SCM, Conductivity, UV254 Organics, Chlorite, Particle Couner, and Biofilm · Membrane-covered three-electrode amperometric Free and Total Chlorine sensors · Automatic temperature compensation · Eventlogging · Capable of providing up to three analog outputs, four relays, and two digital inputs · Isolated inputs and outputs OPTIONAL FEATURES · compensation (free chlorine sensor) pH · flow detector Low · control capability PID · Modbus communiction (RTU or TCP), Residual Chlorine STANDARD FEATURES BENEFITS · reagents or moving parts No · Appropriate for compliance reporting · set up and maintenance Easy · Intuitive menu and programming functions · Reduced pH dependency · purchase and ownership cost Low APPLICATIONS Water Treatment · Online disinfection monitoring · Disinfection dosage control Swimming Pools Paper Machine System Microbial Control Legionella Control Food Washing DESCRIPTION The HydroACT 300 Residual Chlorine Analyzer can measure free chlorine, total chlorine, chlorine dioxide, or pH, and is appropriate for compliance reporting following USEPA Method 334.0. Using a membraned-covered three-electrode amperometric sensor for chlorine measurment, Chemtrac's probe design incorporates a long-lasting electrolyte solution which significantly reduces pH dependency. Because the HydroACT 300 has no moving parts and does not require any reagents or buffers, cost of ownership is low and maintenance is simple. The HydroACT 300 is available with up to three chlorine sensor inputs or one chlorine sensor input and one pH with Temp. sensor input, reducing the overall cost per sample point. Additional measurements such as Ozone, ORP, DO, and Conductivity are also available as sensor options. Chemtrac, Inc. 6991 Peachtree Industrial Boulevard, Building 600 Norcross, GA 30092 USA PH: 770.449.6233 US: 800.442.8722 FX: 770.447.0889 www.chemtrac.com

 Open the catalog to page 1
HydroACT 300 - Residual Chlorine Analyzer-2

GENERAL SPECIFICATIONS Chlorine Dioxide Sensor Probe Analyzer Power Options: Sensor Options: Free Cl, “Zero” Free Cl, Total Cl, Cl Dioxide, Ozone, pH with Temperature, ORP, SCM, DO, TSS/NTU, UV254 Organics, Conductivity, Chlorite, Biofilm, Particle Counter Sensor Inputs: Up to 3 (pH w/ Temp probe requires 2 inputs) Digital Inputs: Up to 3 (750 ohm load) PID option will utilize 1 output Comms Options: Modbus (RTU, TCP), Profibus, or HART Chlorine Sensor Probe (Free or Total)* Type: Measured: Probe Ranges: Membrane-covered amperometric three-electrode system Measured: Probe Ranges: Data Collection...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.