Level
10Pages

{{requestButtons}}

Catalog excerpts

Level - 1

piezometric meters ultrasonic meters

Open the catalog to page 1
Level - 2

Ultrasonic and piezometric level measurement Level/differential meter to control up to 5 pumps Panel-mounted version Wall-mounted version with IP66 protection rating Ultrasonic and piezometric level measurement Measurements Primary measurement Measurement with ultrasonic sensor Measurement with piezometric sensor Secondary measurement Measuring range Technical data Measurement recording Recording interval Circular / Fill Table / Graphic Analogue outputs Instant flow rate Totalised volume Level 1 / Level 2 / Differential / Temperature Programming limit: Lower / Upper Maximum load NAMUR...

Open the catalog to page 2
Level - 3

Technical data Relay outputs Set Point ON – OFF For ultrasonic sensor: 0.30 to 5.00 / 0.40 to 8.00 / 0.70 to 12.00 m For piezometric sensor: 0.00 to 100.00 m Thresholds / Rotation / Timing / Daily / Band / Differential Alarm Function Delay time Relay disabling Enable / Disable for each relay Relay function Closed / Open Stay field Stay time Digital inputs Function Start / Thermal trigger / Max level / Min Level Input voltage Operating conditions Operating temperature Mechanical protection Closed IP65 EN60529 - with transparent panel open IP54 Hardware Display LCD STN Graphic 128x64 Backlit...

Open the catalog to page 3
Level - 4

level measurement level sensors ULTRASONIC TRANSDUCERS [Ultrasonic transducer with measuring range 0.3 to 5 m] ► Precision ± 0.5% of the reading value (of the distance measured) but not greater than ± 2 mm ► Temperature compensation: PT100 from -30 to +80 °C ► Display: red LED for power-on yellow LED for echo ► Power supply: 24 VDC (from ACP 4004 meter) ► Pressure: from 0.5 to 1.5 bar (absolute) ► Protection rating / Electrical connection: - IP 68 with 4-pole 3 m outgoing cable - IP 65 with screw connector + 5 m cable with connector [Ultrasonic transducer with measuring range 0.4 to 8 m] ►...

Open the catalog to page 4
Level - 5

Ultrasonic level measurement The versions available are: 44 wires, 2 relays, MODBUS, 5 m range 42 wires, 5 m range 42 HART wires, 5 m range 42 HART wires, 5 m range, ATEX 44 wires, 2 relays, 5 m range 42 wires, 8 m range 42 HART wires, 8 m range, ATEX 44 wires, 2 relays, 8 m range 44 wires, 2 relays, MODBUS, 8 m range Programming takes place via a removable module (keypad/display.) Once programming is complete, it is possible to remove the module (keypad/display), leaving the level transmitter operational but with no display on board. Technical data Probe body model Casing material...

Open the catalog to page 5
Level - 6

Probe body model Mechanical installation Protection rating Maximum measuring range Casing material 5 m (7 m extended range) [Distances expressed are valid for measurements of perfectly reflective surfaces, otherwise the maximum measurable distance is reduced] 0.4 m with extended range Operating temperature Temperature compensation Electrical connection Internal removable terminal boards (IP66 version) outgoing cable (IP68 version) Internal removable terminal boards Power supply Absorbed power Analogue output Serial communication port Output relays Blocking distance with 2 1/2” fork bracket...

Open the catalog to page 6
Level - 7

Microwave level measurement (RADAR) Characteristics 4The RWL transmitter can perform continuous measurement of the level of dust on solid materials of variable consistency and liquids 4Dust, vapours and temperature variations do not interfere with measurement 4Rope probes are available for measuring loose solids, measuring range up to 30 m 4Rod probes in particular for measuring liquids, measuring range up to 6 m 4Coaxial probes for liquid products, measuring range up to 6 m 4Configuration with guided menu by means of alphanumeric display 4Calibration by means of entering the empty and full...

Open the catalog to page 7
Level - 8

Microwave level measurement (RADAR) RPL devices are instruments for level measurement without contact with the product. The radar pulses emitted by the antenna are reflected from the surface of the product and subsequently received by the antenna itself. The builtin management system on board the RPL devices exploits the flight time to derive the distance of the surface of the product from the probe and, consequently, the level. Using the alphanumeric configuration display, it is possible, in addition to entering all the data for level measurement, to display and isolate any false level...

Open the catalog to page 8
Level - 9

Characteristics 4Continuous non-contact level measurement of solids, liquids, pastes and sludge 4Independent measurement of variations of the physical characteristics of the product 4Dust, vapours and temperature variations do not interfere with measurement 4Configuration with guided menu by means of alphanumeric display 4Calibration by means of entering the empty and full distances without product movement on the alphanumeric display 42/4 wire technology 4Level and curve measurement of the echo signal shown on the alphanumeric display 4Storage system and recognition of false echo signals...

Open the catalog to page 9
Level - 10

Capacitive measurement Continuous level measurement tanks with mass reference; Capacitive double rod probe Capacitive rope probe for tanks with mass reference Capacitive rope probe for chemical/food industry non-conductive liquids tanks with mass reference ON/OFF level control Standard rod level switch level control or side of metal tanks level control conductive liquids or side of metal tanks Insulated rope level level control Rope level level control conductive liquids Level switch for plastic level control aggressive products plastic tanks

Open the catalog to page 10

All CHEMITEC catalogs and technical brochures

  1. Pressure

    4 Pages

  2. Analizzatori

    12 Pages

  3. Flow

    14 Pages

  4. Recording

    3 Pages

  5. Analysers

    12 Pages

  6. Samplers

    4 Pages

  7. EchoSmart

    2 Pages