Electromagnetic Flow Meters
  • Components and Functionality: These meters consist of a sensor and transmitter to measure the volumetric flow rate of conductive fluids, independent of fluid density, viscosity, temperature, and pressure. They require fluid conductivity greater than 5μS/cm.
  • Installation: Requires straight pipe sections upstream (3x diameter) and downstream (2x diameter). Can be installed vertically or horizontally, ensuring the pipe is always full.
  • Technical Specifications: Available in various pipe diameters, with a velocity range of 0-10 m/s. Made from materials like AISI 321 stainless steel and Hastelloy, with protection ratings of IP67/IP68, accuracy of ±0.5%, and repeatability of 0.07%.
  • Special Features: Includes low-frequency magnetic excitation, a high-precision microprocessor, and supports MODBUS, HART, and PROFIBUS protocols, along with self-test and self-diagnosis functions.
Ultrasonic Flow Meters
  • Types: Includes transit time and Doppler effect meters, suitable for open channels with ultrasonic or piezometric sensors.
  • Measurement Ranges: Flow: 0 to 9999 m³/h, Level: 0.30 to 5.00 m, Temperature: 0 to 100 °C.
  • Technical Specifications: Precision of ±0.2% F.S., with various output options including RS485 MODBUS, analogue outputs, and relay outputs.
  • Environmental Conditions: Operates in temperatures from -25°C to +75°C, with humidity levels of 10-95% non-condensing.
General Recommendations
  • Ensure proper installation to maintain measurement accuracy.
  • Regular maintenance and calibration are recommended for optimal performance.
  • Consider environmental conditions and fluid properties when selecting the appropriate flow meter type.
Flow Measurement Systems Overview: The document details technical specifications and operational principles for various flow measurement systems, including models like 100F, 100H, DFM-5.0, and AVFM-II, utilizing ultrasonic and Doppler effect technologies.
100F Flow Measurement System:
  • Composed of a digital converter and ultrasonic transducers, operating on the transit time principle for instantaneous flow rate calculation.
  • Suitable for pipe diameters from 20 to 4000 mm, featuring DSP technology for low sensitivity to disturbances.
  • Configuration values stored in a password-protected EEPROM, with a clock and battery operation for data retention during power failures.
  • Technical specifications include a velocity range of ±32m/s, linearity of 0.5%, and total accuracy of ±1%.
100H Flow Measurement System:
  • Portable system with features similar to the 100F model, including a digital converter and ultrasonic clamp-on transducers.
  • Operates on the transit time principle, suitable for pipes from DN 15 to 4000 mm, with a data logger capacity of 2000 records.
  • Power supply options include external power or rechargeable batteries.
DFM-5.0 Doppler Effect Flow Meter:
  • Suitable for liquids with solids or air bubbles, using the Doppler effect to measure flow rate by detecting frequency changes in reflected sound waves.
  • Measuring range from 0.08 to 12.2 m/sec for pipes from 12.7 mm to 4.5 m, featuring a 4-digit LCD display and adjustable sensitivity.
  • Portable with a rechargeable battery for up to one day of operation.
AVFM-II Area x Velocity Flow Meter:
  • Measures flow rate by calculating the area and velocity of fluid in open channels or pipes, with a sensor mounted inside the pipe or on the channel bottom.
  • Measuring range for velocity from 0.03 to 6.2 m/sec and level from 25.4 mm to 4.57 m, with automatic temperature compensation and a programmable data logger.
General Features and Recommendations:
  • All systems are designed for easy installation and calibration without interrupting plant operations.
  • Transducers are non-invasive, reducing wear and maintenance needs, suitable for a wide range of liquids and pipe materials.
  • Data protection through password security and power failure safeguards.
STINGRAY Portable Flow Meter Overview: Designed for continuous monitoring of water flow in open channels and partially filled or pressurized pipes, using a submersible ultrasonic sensor.
Specifications:
  • Temperature Range: -20 to +60 °C, Precision: Level ±0.25% of range, Velocity ±2% of reading.
  • Power Supply: 4 alkaline batteries, Outputs: RS232, 28,800 baud rate.
  • Sensor Material: PVC, polyurethane, epoxy resin, with a submersible sensor cable.
Features:
  • Ultrasonic level and velocity measurement, no calibration required, with automatic display shut-off after 60 seconds to save power.
  • Data logger with 130,000 memory points, and powerful Windows-based software for real-time monitoring.
  • LCD display with bar graph for velocity, level, temperature, battery charge, and memory capacity.
Installation and Options:
  • Includes sensor with a 7.6 m cable, installation accessory, batteries, and software, with optional 15 m sensor cable.
  • Stainless steel mounting bracket for sensor installation, suitable for stainless steel pipes from 150 to 1800 mm.
Applications: Suitable for studying and monitoring flow rates, infiltration, irrigation, and treatment water.
See more

Catalog excerpts

Flow-1

Flow rates Flow rates 4Electromagnetic meters 4Ultrasonic “transit time” meters 4Ultrasonic “Doppler” effect meters

 Open the catalog to page 1
Flow-2

Electromagnetic induction flow meters An electromagnetic flow meter consists of a sensor and a transmitter. The flow meter is used to measure the volumetric flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and pressure. The conductivity of the fluid must be greater than 5μS/cm. The measuring instrument must not be crossed by fluids carrying solid bodies of high dimension that cannot be considered suspended solids. Head losses are absent and straight stretches reduced upstream and downstream of the instrument are necessary. Several...

 Open the catalog to page 2
Flow-3

Electromagnetic induction flow meters Guide to choosing the best measuring pipe

 Open the catalog to page 3
Flow-4

Electromagnetic induction flow meters Operating conditions Ambient temperature Relative humidity Ambient pressure Environmental conditions Conductivity of the fluid >5μS/cm 4.0 MPa (DN15 to DN150) Pressure Process temperature remote version < 80 °C (rubber coating) < 150 °C (180 °C peak, PTFE coating) compact version < 70 °C Power supply Electrical consumption Technical data Sensor Flow rates Velocity range Measuring pipe material Type of coating Electrode material Flange material Protection rating 0m/s to 10m/s AISI 321 stainless steel Rubber, PTFE, FEP (DN10) AISI 316 Ti stainless steel, Hastelloy...

 Open the catalog to page 4
Flow-5

Electromagnetic induction flow meters Ambient pressure Operating conditions Ambient temperature Relative humidity Environmental conditions Conductivity of the fluid >5μS/cm 4.0 MPa (DN10 to DN150) Pressure Process temperature remote version: < 80 °C (rubber coating) compact version: - 20 to + 70 °C Power supply Electrical consumption Technical data DN pipe Velocity range Measuring pipe material Type of coating Electrode material Flange material Protection rating 0 to 10m/s AISI 321 stainless steel Rubber, PTFE, (up to DN 500) AISI 316 stainless steel, Hastelloy C UNI 2223 carbon steel compact...

 Open the catalog to page 5
Flow-6

Electromagnetic induction flow meters Ambient pressure Operating conditions Ambient temperature Relative humidity Environmental conditions Process temperature remote version: < 120/150 °C (PTFE coating) compact version: - 40 to + 75 °C Power supply Typical electrical consumption Technical data Flow rates Sensor DN pipe Velocity range Measuring pipe material Type of coating Electrode material Flange material Protection rating Microprocessor 10,15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 0.2 to 10m/s SS302 stainless steel PTFE /PFA AISI 316 stainless steel, Hastelloy C, Titanium, Tantalum Liner...

 Open the catalog to page 6
Flow-7

Flow meters for open channels with ultrasonic or piezometric sensor Panel-mounted version Wall-mounted version with IP66 protection rating Flow meter for channels with constricted sections Measurement Measuring ranges Flow: 0 to 9999 m³/h - Level: 0.30 to 5.00 m - Temperature: 0 to 100 °C Flow: m³/h, l/sec - Level: m, cm, mm - Temperature: °C Types of devices/exponents for calculating PMD (primary measuring device) flow RECTANG (rectangular weir) / TRAPEZ (Cipolletti weir) / VENTURI (channel with constricted section) / PARSHALL (Parshall channel) / L LEOPOLD (Leopold Lagco channel) / V. WEIR...

 Open the catalog to page 7
Flow-8

Technical data Recording measurements Instant flow rate Totalised volume Recording interval Circular / Fill Circular / Fill Graph: minimum, maximum and average values for the period and zoom function Analogue outputs Quantity Flow / Temperature / Level Programming limit: Lower / Upper Maximum load NAMUR compliant alarm output Relay output no. 5 Function – selectable ON-OFF with hysteresis Alarm Echo loss alarm threshold Flow rates Time out (echo absence time): 00:00 to 24:00 h Operating conditions Operating, storage and transport temperature Mechanical protection Closed IP65 EN60529 - with transparent...

 Open the catalog to page 8
Flow-9

Ultrasonic “transit time” meters The 100F flow measurement system is composed of a digital converter for wall installation and two ultrasonic clamp-on or insertion transducers. The transit time of a fluid inside a pipe with a cylindrical section is the operating principle on which the instrument is based to calculate the value of the instantaneous flow rate. DSP, Digital Signal Processing, technology ensures low sensitivity of the system to any potential disturbing factors. The dimensions of the pipe may vary from 20 to 4000 mm (by using different transducers) while liquids can be: ultra-pure,...

 Open the catalog to page 9
Flow-10

Portable “transit time” flow meters The 100H flow measurement system is composed of a portable digital converter and two ultrasonic clamp-on transducers. The transit time of a fluid inside a pipe with a cylindrical section is the operating principle on which the instrument is based to calculate the value of the instantaneous flow rate. DSP, Digital Signal Processing, technology ensures low sensitivity of the system to any potential disturbing factors. The dimensions of the pipe may vary from 20 to 4000 mm (by using different transducers) while liquids can be: ultra-pure, drinking water, chemicals,...

 Open the catalog to page 10
Flow-11

“Doppler” effect flow meter The DFM-5.0 effect flow transmitter is suitable for most liquids, such as water, waste water, chemical liquids, sludge and viscous liquids. It controls, indicates, totalises and transmits the flow rate in gallons, litres or other units of measurement. The sensor is mounted on the outside of a pipe made of metal or plastic. To measure the flow rate, the acoustic pulses, generated by the sensor, are reflected by the particles or gas bubbles, present in the liquid, and are sent back to the sensor. Installation can be done without stopping the plant. There is no contact...

 Open the catalog to page 11
Flow-12

PDFM-5.0 The PDFM-5.0 Doppler effect flow meter is suitable for monitoring a flow rate or for identifying problems encountered in a closed pipe. It is an ideal instrument for evaluating the performance of flow meters inserted in line. It can be installed, calibrated and operated in a few minutes and then used as a temporary replacement for an in-line transmitter. Easy to transport Each PDFM-5.0 unit comes with a convenient and stylish carrying case, the sensor, and a stainless steel installation kit. The unit can be used for a short time or left in a position to transmit and/or record data. Energy...

 Open the catalog to page 12

All CHEMITEC catalogs and technical brochures

  1. Pressure

    4  Pages

  2. Level

    10  Pages

  3. Analizzatori

    12  Pages

  4. Recording

    3  Pages

  5. Analysers

    12  Pages

  6. Samplers

    4  Pages

  7. EchoSmart

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.