Analysers

Analysers
1 / 12 PagesView full catalog

Analysers

Product catalog summary
UV Meter
The UV Meter is an automatic on-line analyser equipped with a touchscreen display and a UV lamp with a lifespan of 10 years. It includes an internal data logger and optional RS 232 data download. It measures COD and nitrates without reagents, except for NaOH for ammonia. The device is compact, features an automatic washing system, and uses a peristaltic pump for sampling, designed for low running costs and minimal maintenance.
On-line C.O.D. Analysers
These analysers use UV spectrophotometry based on the Beer-Lambert law to measure organic molecules, automatically compensating for turbidity and other interferences. They comply with AFNOR X PT 90-210 and DIN38404-C3 standards, suitable for monitoring surface water and water treatment plants, offering fast analysis times and limited maintenance.
On-line Nitrate Analysers
These analysers measure nitrates using UV absorption at 210-220 nm, automatically compensating for turbidity and other interferences. They are designed for monitoring surface water and water treatment plants, with fast analysis times and minimal maintenance.
On-line Ammonium Analyser
This analyser uses UV absorption in the NH3 gas phase, with NaOH added to convert NH4+ to NH3. It features an automatic washing system and does not require filtration, suitable for monitoring surface water and water treatment plants.
On-line Hydrocarbons Analyser
Using fluorescence, this analyser detects aromatic hydrocarbons in water, suitable for various water types, including surface and drinking water, offering fast analysis times and minimal maintenance.
TOC Meter
The TOC meter measures total organic carbon using oxidation with sodium persulfate and UV irradiation, complying with EPA and ISO standards. It is suitable for various water monitoring applications, featuring high accuracy, low maintenance, and reduced reagent consumption.
Color Meter
This compact analyser performs on-line colorimetric determination with a thermostat-controlled cell, suitable for monitoring drinking water and wastewater treatment efficiency. The system is robust, reliable, and easy to install.
Filtration System for Analysers
The SF-100 filtration system is a self-cleaning filter using compressed air to maintain cleanliness, designed to prevent rapid dirt accumulation, often used upstream of online analysis systems.
Technical Specifications:
  • Filter Body Material: Polypropylene (PP)
  • Filter Element Material: AISI 316 stainless steel
  • Filter Element Passage Dimension: 100 microns
  • Temperature Range: 2 to 55°C
  • Protection Rating: Timer & solenoid valve IP 65
  • Sample Line Pressure: Minimum 0.3 Bar, Maximum 2.5 Bar
  • Sample Line Flow: Minimum 0.1 m3/h
  • Backwashing Compressed Air Pressure: At least 20% above sample line pressure, up to a maximum of 3 bar
  • Filtered Sample Flow: 0.1 to 2 l/min depending on sample line pressure
  • Hydraulic Filter Inlet/Outlet Connections: 1" NPT
  • Compressed Air Inlet Connection for Washing Pipe: ¼”
  • Parts in Contact with Solenoid Valve Liquid: AISI 16 stainless steel - Viton
  • Electric Power Supply: 220-240 Vac
  • Power Consumption: 20VA
  • Washing Frequency: Programmable from 1 to 45 minutes
  • Washing Duration: Programmable from 1 to 30 seconds
  • Filter Weight: 1 kg
Procedures:
  • The filter element undergoes an automatic backwashing process to remove solid particles trapped on its outer surface.
  • The frequency and duration of the washing cycle can be programmed by the user within a wide range of values.
See more

Catalog excerpts

Analysers-2

Automatic on-line analysers UV lamp How cell Reference ► Control with touchscreen display ► "Long life" UV lamp - 10 years ► Internal data logger with data download via UV lamp Row cell Referena Excitation filter Emission filter Photomultiplier UV-VIS lamp How cell pholodelector ► No reagent (except for NaOH ► Built-in automatic washing ► Extremely fast response time ► The running costs are very low measurement principle does not ► Extremely simple hydraulic system with pipes with large ► The automatic cleaning system keeps the measuring cell clean for long periods with no need for intervention....

 Open the catalog to page 2
Analysers-3

The measuring principle is based on the intense UV absorption of the organic molecules at 254 nm in accordance with the Beer-Lambert law: ⎛ Iin ⎞ [ C ] = k • log⎜— ⎜ — ⎝ Iout ⎠ [C]: concentration of the sample k: extinction coefficient Iin: intensity of light input sample Iout: intensity of light output sample Turbidity, organic substances, suspended solids or dirt in the measuring cell are compensated for automatically by means of a differential measurement with a second detector at a different wavelength. Complies with AFNOR X PT 90- 210 – DIN38404-C3 standards. Applications 4Monitoring surface...

 Open the catalog to page 3
Analysers-4

On-line nitrate analysers Analysers The measuring principle is based on the intense UV absorption of the NO chromophore at 210-220 nm according to the Beer-Lambert law: ⎛ Iin ⎞ [ C ] = k • log⎜— ⎜ — ⎝ Iout ⎠ [C]: concentration of the sample k: extinction coefficient Iin: intensity of light input sample Iout: intensity of light output sample Automatic linearization stored in the analyzer is used to compensate the nonlinearity of the Beer-Lambert law for high concentrations.The measurement is the weighted sum of the concentrations of NO2 and NO3, although, in most applications, the concentration...

 Open the catalog to page 4
Analysers-5

The measuring principle is based on the UV absorption of ammonia in the NH3 gas phase. The addition of a small amount of sodium hydroxide (NaOH) to the sample allows the almost complete passage (stripping) of the ammonium ion NH4+ to the NH3 gaseous form. An FFT (Fast Fourier Transform) algorithm is applied to the spectrometer to extract the absorption signal typical of ammonia gas. This method is very selective as no interferent is entrained for determination on surface water or waste water. Turbidity or the colour of the sample do not influence the measurement, as the determination is made...

 Open the catalog to page 5
Analysers-6

On-line analyser for hydrocarbons in water Excitation filter Emission filter Photomultiplier UV-VISIamp Flow cell photodetector a high sensitivity photomultiplier, even very low concentrations (of be determined. The table shows the relative intensity measurements of certain aromatic hydrocarbons: water (BTEX, PAH, phenol, oil, Technical data

 Open the catalog to page 6
Analysers-7

Measuring T.O.C. - Total Organic Carbon Measuring principle The analyser measures total organic carbon (TOC) using a method which oxidises the aqueous sample in the presence of sodium persulfate and UV irradiation and then measures the carbon dioxide produced using a non-dispersive infrared (NDIR) analyser. The method has been approved by the US Environmental Protection Agency (EPA) and complies with ISO/CEN European guidelines. The analyser is able to take this type of measurement from aqueous samples in a field that ranges from 0 - 5 mg/l up to a maximum of 10,000 mg/l (others on request)....

 Open the catalog to page 7
Analysers-8

TOCMETER Analysers The “TOC Meter” analyser takes continuous measurements of the total organic carbon by means of oxidation with sodium persulfate and UV irradiation, after removal of inorganic carbon by means of acidification with phosphoric acid (EPA Method 415.1, in accordance with EN 1484, ISO 8245). CO2 is measured by means of a built-in high stability NDIR. Characteristics 4TOC analysis with high accuracy and repeatability. 4High stability NDIR sensor. 4Internal system for generating and purifying the carrier gas. No additional cylinders or air treatment systems required. 4Intuitive user...

 Open the catalog to page 8
Analysers-9

The “COMPAC TOC” analyser takes batch measurements of the total organic carbon by means of oxidation with sodium persulfate and UV irradiation, after removal of inorganic carbon by means of acidification with phosphoric acid (EPA 415.1 method, in accordance with EN 1484, ISO 8245). CO2 is measured by means of a built-in high stability NDIR. Characteristics 4TOC analysis with high accuracy and repeatability. High stability NDIR sensor with no moving parts. 4Sampling method: discontinuous at settable frequency. 4The only analyser that can be powered at low voltage (12 VDC - Compactoc-LV model)....

 Open the catalog to page 9
Analysers-10

Color meter on-line colorimetric determination General characteristics ► Intuitive touchscreen user colorimetric cell (approx. 35 validation / cleaning ► Built-in peristaltic pump for sample collection ► Sample recirculation barrel with level contact ► Dedicated drainage for samples containing analysis reagents ► Sampling method: discontinuous with settable Developed and manufactured for the industrial environment and on-line environmental applications, it is characterised by high levels of robustness of the electronic, mechanical and hydraulic components. The analyser is delivered after a long...

 Open the catalog to page 10
Analysers-11

Analysers 4Complete separation of the electronic part from the hydraulic part. Technical data Measuring principle Colorimetric analysis Measuring range in relation to the analytical method used Analysis time Analysis frequency Maximum error 2% of the measurement range full scale Thermostat control Reagents / cleaning solution in relation to the analytical method used Analogue outputs 2 relays (settable as threshold, fault…) Optional, depending on the sample matrix Ambient temperature Sample temperature Data logger Built-in (optional) Power supply Running costs Extremely limited Installation time...

 Open the catalog to page 11
Analysers-12

Filtration system for analysers The SF-100 filtration system, often used upstream of online analysis systems, is a self-cleaning filter that uses compressed air with a programmable frequency to keep the stainless steel filter element clean. While most of the liquid in analysis passes very quickly passes through the polypropylene body of the filter, only the amount necessary for the analyser is filtered through the stainless steel filter element with a special profile. This prevents a rapid accumulation of dirt and deposits on the filter element. In addition to this, the filtration system uses...

 Open the catalog to page 12