1. Catalogs
  2. ChefsTemp (Leadtek Inc.)
  3. ChefsTemp Quad XPro Alarm Thermometer Operating Instruction

ChefsTemp Quad XPro Alarm Thermometer Operating Instruction

ChefsTemp Quad XPro Alarm Thermometer Operating Instruction
1 / 24 PagesView full catalog

ChefsTemp Quad XPro Alarm Thermometer Operating Instruction

Product catalog summary
Overview: The ChefsTemp Quad XPro is a BBQ alarm thermometer that allows remote monitoring of cooking temperatures up to 500 feet/150 meters. It features a large LCD display, backlight, magnetic back, and can switch between °C/°F. It includes four probes and a temperature alarm function.
Package Content: The package contains the main unit, receiver, three stainless steel probes, one ambient probe, probe rings, a probe clip, a hanging lanyard, and an instruction manual.
Product Specifications: The main unit and receiver are splash-proof with specific dimensions. The probes have a temperature range of -58 to 572°F and are water-resistant. The device operates on AA batteries or a Type-C cable and has a transmission distance of 500 feet.
Operating Instructions: To begin, insert batteries into the receiver and main unit, connect the probes, and ensure synchronization within 30 seconds. Settings allow switching between Celsius and Fahrenheit, adjusting alarm volumes, and setting temperature alarms.
Temperature Alarm Function: The alarm activates if the temperature exceeds set limits, with different beep frequencies for each channel. The receiver also vibrates when an alarm is triggered.
Low-battery Reminder Mode: A flashing symbol indicates low battery, affecting alarm functionality. Pressing any key exits the reminder mode.
Syncing and Installation: Instructions are provided for manually syncing the main unit and receiver and installing probe rings.
Calibration Guide: Calibration is optional and adjustable within a range of ±3.6°F.
Use & Maintenance: Tips include avoiding direct attachment to high heat sources and proper probe placement. Cautions are provided for probe and cable handling.
Troubleshooting: Solutions are provided for common issues such as no alarm sound, signal reception problems, and temperature display errors.
Contact Information: Users are encouraged to contact support if they experience issues with the device.
Community Overview: Join a community of cooking enthusiasts sharing ideas and suggestions on cooking, smoking, BBQ, and more. Members can share recipes and learn from others worldwide. New members receive free E-cookbooks as a welcome gift.
Contact Information: Phone: +1(559)563-8838, Email: [email protected], Facebook: www.facebook.com/ChefsTemp/, Website: www.chefstemp.com
Chef-Recommended Meat Temperatures:
  • Beef: Blue (110°F/43°C), Rare (120-130°F/49-54°C), Medium Rare (130-135°F/54-57°C), Medium (135-145°F/57-63°C), Medium Well (145-155°F/63-68°C), Well (155°F-up/68°C-up), Ground Beef (160°F/71°C), Beef Brisket - BBQ (190-205°F/88-96°C)
  • Pork: Medium (137°F/58°C), USDA - Done (145°F/63°C), Well Done (150°F-up/66°C-up), Pre-Cooked Ham (120°F/49°C), Sausage (160°F/71°C), Pork Ribs - BBQ (190-205°F/88-96°C), Pork Shoulder - BBQ (190-205°F/88-96°C)
  • Poultry: USDA & Chef Recommended (165°F/74°C), Safe at 165°F but more tender at a higher temp (170-180°F/77-82°C)
  • Seafood: Ahi Tuna (115°F/46°C), Shrimp (120°F/49°C), Salmon (125°F/52°C), Halibut (130°F/54°C), Scallops (130°F/54°C), Lobster (140°F/60°C)
See more

Catalog excerpts

ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-1

Quad XPro Alarm Thermometer ChefsTemp Quad XPro Alarm Thermometer Operating Instruction Preset Temp Magnetic Back °C/°F Switchable Temperature Alarm

 Open the catalog to page 1
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-3

1. ChefsTemp Quad XPro Info Sheet 1.1 Overview Monitoring temperature from your yard or house has been made easier with ChefsTemp Quad XPro BBQ Alarm Thermometer. The Quad XPro allows you to stay connected and track real-time cooking temperatures of your food with a transmission distance up to 500 feet/150 meters (1m above the ground), ensuring that your food is at the right temperature and perfectly smoked every time. If the temperature is over the high or low target settings, the Quad XPro will sound and send signals to the Receiver. It's effective 4 channel splash proof casing, and RF remote...

 Open the catalog to page 3
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-4

1.3 Product Specification Display Size: ChefsTemp Quad XPro Main Unit: 3.66Hx2.09W inches (93Hx53W mm) ChefsTemp Quad XPro Receiver: 1.42Hx2.02W inches (36Hx51.3W mm) Product Size: ChefsTemp Quad XPro Main Unit: 5.94Hx3.74Wx1.18D inches (150.8Hx95Wx30D mm) ChefsTemp Quad XPro Receiver: 2.44Hx3.84Wx1.4D inches (62Hx97.5Wx35.5D mm) Probe Range: -58 to 572°F (-50 to 300°C) Probe Cable Withstand Temperature: Max 700°F (370°C) Transmission Distance: 500ft (150m) in rural areas (1m above the ground) Accuracy: ±0.9°F (±0.5°C) from 32 to 212°F (0 to 100°C) ±1.8°F (±1.0°C) from 212 to 572°F (100 to 300°C)...

 Open the catalog to page 4
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-5

Operating Range: 32 to 122°F (0 to 50°C) Main Unit and Receiver Power Supply: 2 AA size 1.5V batteries (not included) The Main Unit can be powered by a Type-C cable (not included) The Main Unit and Receiver include bracket and back-lit magnet The Receiver has a hanging hole and vibration function 1.4 Button and Interface Introduction Main Unit (Front)

 Open the catalog to page 5
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-7

Main Unit (Back) seconds to turn off. Calibration Function Celsius/Fahrenheit Press to transmit signals to Long press to turn off the signal transmission.

 Open the catalog to page 7
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-8

Receiver (Front) When the Receiver is turned on, press to turn backlight on. Long press for 3 seconds to turn off. Adjust volume level. Long press for 2 seconds to receive signals manually.

 Open the catalog to page 8
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-9

Receiver Screen Volume Level Signal Reception Indicator Current Temperature HIGH ALARM Alarm ON/OFF State LOW ALARM Channel Number

 Open the catalog to page 9
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-11

2. Operating Instruction 2.1 Getting Started Step 1: Open the bracket and slide down the Receiver battery cover to insert 2 AA batteries. Once batteries are inserted, the Receiver will automatically turn on with two beeps and display a backlight, then it will enter the signal receiving state. Step 2: Insert the probe into the Main Unit, up to 4 can be inserted. Step 3: Open the back cover of the Main Unit with a screwdriver and insert 2 AA batteries (or plug in the Type-C cable). The Main Unit will automatically turn on with two beeps and display a backlight, then display the temperature of the...

 Open the catalog to page 11
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-12

• When the Main Unit uses a Type-C cable and batteries at the same time, the Main Unit will not use the power supply of the batteries. The Type-C cable will not charge batteries inside the Main Unit. Press to switch between Celsius and Fahrenheit. Press |(j '*»-// to adjust the alarm volume level, there are 5 volume levels available. The volume levels displayed on the device are shown below: • L-uLUnE.il -> HUTE.ill -> <H)LUIT -> WLlflE. -> WJLUnE.i to turn the backlight on for 20 seconds, the backlight will turn off after pressing Long press I set 1 for 3 seconds to reset the maximum and minimum...

 Open the catalog to page 12
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-13

Step 3 ■ Use r + t° adjust the desired LOW ALARM temperature. Press jf set | again (or no operation for 20 seconds) to confirm LOW ALARM setting and exit the temperature setting mode. j to turn the alarm function on or off for a specific channel. Use "Off" to turn off alarm sounds. When setting the HIGH ALARM, if there is no operation for 20 seconds, the current setting will be automatically saved and the setting mode will be exited. When the device is powered off, the settings will be saved on the device unless the batteries and Type-C cable are removed or the batteries exhausted and Type-C...

 Open the catalog to page 13
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-14

3. Temperature Alarm Function 3.1 Main Unit When the alarm function is turned on, and the measured temperature is higher than the HIGH ALARM temperature, or lower than the LOW ALARM temperature set, the alarm will sound, the backlight will begin flashing, and the measured temperature digits will flash. There are 4 kinds of temperature alarm sounds, each channel has a different alarm frequency: CH 1: beep once per second CH 2: beep twice per second CH 3: beep 3 times per second CH 4: beep 4 times per second Pressing any button on the Main Unit will turn off the alarm. If multiple channels alarm...

 Open the catalog to page 14
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-15

CH 1: beep once per second CH 2: beep twice per second CH 3: beep 3 times per second CH 4: beep 4 times per second Pressing any button on the Receiver will turn off the alarm. If multiple channels alarm at the same time, only the last alarm will sound. 4. Low-battery Reminder Mode 4.1 Main Unit When the power of the Main Unit is low, the screen will only display the flashing symbol, and the alarm will not functioning. Press any key to end the low battery reminder mode, all displays and functions will return to normal, but the symbol still 4.2 Receiver When the power of the Receiver is low, the...

 Open the catalog to page 15
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-16

5. How to Sync Main Unit and Receiver Manually If you need to sync the Main Unit and Receiver manually, please follow the steps below: Step 1: Hold and the on the Receiver to enter the signal receiving state. After one beep, all data of the Receiver will be reset icon will begin flashing. on the back of the Main Unit to send signals manually. The Icon will begin flashing on the Main Unit while the Receiver will begin connecting with the Main Unit and receiving data from it. Note: When the Receiver loses signal for 30 seconds, the alarm will automatically ring, the backlight will be flashing and...

 Open the catalog to page 16
ChefsTemp Quad XPro Alarm Thermometer Operating Instruction-17

First Probe Ring: Step 1: Slide the first of the two matching probe rings over the probe tip. Step 2: Roll the probe ring over the metal springs of the probe. Step 3: Slide the probe ring down the cable until it is over the metal springs of the probe jack. There will be a slight groove to hold the probe ring in place. Step 2: Roll the probe ring over the PEEK of the probe. Step 3: Place the probe ring at the point Second Probe Ring: Step 1: Holding the second probe ring, slide probe ring over the probe. where the metal spring and the PEEK meet.

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.