1. Catalogs
  2. CHC Lab Co., Ltd.
  3. CleaAir Fume Hood

CleaAir Fume Hood

CleaAir Fume Hood
1 / 13 PagesView full catalog

CleaAir Fume Hood

Product catalog summary
Overview: The document details the specifications and features of CleAir® Fume Hoods by CHC LAB, designed for laboratory safety and efficiency. These hoods protect researchers and the environment from harmful substances and gases.
Key Features:
  • Efficiency: Utilizes aerodynamic technology for stable air maintenance and energy saving, with quick air monitoring to adjust air velocity.
  • Safety: Features large sight glass sash structures for wide visibility, safety gas valves, and ergonomic airfoil structures to prevent gas concentration and leakage.
  • Design: Designed using CFD simulations for optimal ventilation, with baffle and bypass structures for effective air emission and pressure management.
  • Materials: Constructed with chemical-resistant materials like phenolic laminate and tempered safety glass for durability.
Model Specifications:
  • Fume Hood CLE-101: Bypass Air Type, dimensions 1200mm to 2400mm, with sliding doors and tempered glass.
  • Fume Hood CLE-106: Air Curtain Type, similar to CLE-101, includes an air curtain fan.
  • Fume Hood CLE-107: Auxiliary Air Type, 2500mm height, with stainless steel door sash.
  • Fume Hood CLE-109: Low Work-in Type, up to 7200mm width, for extensive setups.
  • Fume Hood CLE-110: Walk-in Type, large dimensions for walk-in environments.
  • Fume Hood CLE-120: Center Tabletop Type, 1600mm height, for central placement.
  • Fume Hood CLE-121: Side Tabletop Type, up to 2400mm width, for side placement.
Additional Features: All models offer additional receptacles, service valves, epoxy resin worktops, explosion-proof lamps, and selectable power receptacles (220V/110V).
CleAir® Fume Hood:

Overview: A ductless system ensuring safety and efficiency, featuring a utility hole, optional water tap and cupsink, and an LCD controller.

Specifications:
- Dimensions: 900mm and 1200mm width.
- Materials: 8mm acrylic (PMMA) and steel plate with epoxy powder coating.
- Performance: Noise level ≤ 65db(A).
- Filters: Pre-filter, optional HEPA and carbon filters.

Features:
- Three-sided visibility with clear acrylic.
- Anemometer for air velocity.
- Leveling caster for mobility.
CleAir® Armhood:

Overview: Designed for quick emission of contaminated air, with a polyarticular structure and filter box attachment.

Specifications:
- Models: CLE-001-05, CLE-020, CLE-040, CLE-030 (Filter box).
- Materials: Transparent acrylic (PMMA).
- Filter System: Carbon, HEPA, and pre-filters in cartridge shape.

Applications: Suitable for various settings, adjustable for air velocity, compatible with different surfaces.
Contact Information: CHC LAB, Daejeon, South Korea. Tel: +82-42-933-0887, Email: [email protected], Website: www.chclab.com
See more

Catalog excerpts

CleaAir Fume Hood-1

CleAir Fume Hood Center Tabletop Side Tabletop

 Open the catalog to page 1
CleaAir Fume Hood-2

Exhaust system equipment is an essential equipment to secure the safety of the researchers as well as the laboratory from the harmful substances and contaminated gas which are emitted during the research process. Operation of the efficient and pleasant research facility is supported as the aerodynamic technology is applied for the stable maintenance of proper air amount together with the energy saving.

 Open the catalog to page 2
CleaAir Fume Hood-3

CleAir FUME HOOD //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Air velocity monitor Option Fume Hood Energy saving effect can be expected as the quick monitoring of the air amount is available in accordance with the change of air velocity by the opening and closing...

 Open the catalog to page 3
CleaAir Fume Hood-4

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Bypass Air Type Unit : mm W : Width D : Depth H : Height Room air Contaminanted air under negative pressure Front view Model No. General specification General specification Power receptacle Side view...

 Open the catalog to page 4
CleaAir Fume Hood-5

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Air Curtain Type Unit : mm W : Width D : Depth H : Height Contaminanted air under negative pressure Front view Model No. General specification Up/Down sliding door type Lamp switch Steel plate 1.6mm...

 Open the catalog to page 5
CleaAir Fume Hood-6

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Auxiliary Air Type Unit : mm W : Width D : Depth H : Height Contaminanted air under negative pressure Front view Model No. General specification General specification Power receptacle Side view Lamp...

 Open the catalog to page 6
CleaAir Fume Hood-7

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Low Work-in Type Unit : mm W : Width D : Depth H : Height Contaminanted air under negative pressure Front view Model No. General specification Color Door (Up/Down sliding door type) Airfoil Cabinet...

 Open the catalog to page 7
CleaAir Fume Hood-8

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Walk-in Type Unit : mm W : Width D : Depth H : Height Airflow Room air Contaminanted air under negative pressure Front view Model No. General specification Color Door (Up/Down sliding door type) Tempered...

 Open the catalog to page 8
CleaAir Fume Hood-9

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Center Tabletop Type Unit : mm W : Width D : Depth H : Height Airflow Room air Contaminanted air under negative pressure ※ Option : Table, Drawer Front view Model No. General specification General specification...

 Open the catalog to page 9
CleaAir Fume Hood-10

CleAir FUME HOOD //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Side Tabletop Type Unit : mm W : Width D : Depth H : Height Airflow Room air Contaminanted air under negative pressure ※ Option : Table, Drawer Model No. General specification Support stand Interior...

 Open the catalog to page 10
CleaAir Fume Hood-11

CleAir FUME HOOD /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB Freely movable DUCTLESS FUME HOOD Ductless Fume Hood CLE-051F-03 Carbon filter (option) HEPA filter (option) Pre-filter Anemometer It is available to check easily air velocity inside the chamber. Filter...

 Open the catalog to page 11
CleaAir Fume Hood-12

The armhood of polyarticular structure protects researchers and environment from the contaminated substances through the quick emission of the contaminated air generated at the local experiment place. CLE-020 The movable armhood is used by attaching the armhood to the filter box emits clean air after the noxious substances are filtered, and the air velocity can be adjusted with the controller. CLE-040 Noxious gas generated at local places are emitted outside through a duct, and observation of the work place is convenient as the four sides are made of transparent acrylic (PMMA). CLE-030 (Filter...

 Open the catalog to page 12

All CHC Lab Co., Ltd. catalogs and technical brochures

  1. Lab Furniture

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.