1. Catalogs
  2. CHAUVIN ARNOUX
  3. ULYS MD45 & ULYS MD100
video corpo

ULYS MD45 & ULYS MD100

ULYS MD45 & ULYS MD100

ULYS MD45 & ULYS MD100

Product catalog summary
Overview: The document provides technical specifications and features of the ULYS MD45 and ULYS MD100 submeters, designed for single-phase networks with direct connection capabilities up to 100 A. These devices are equipped with built-in RS485 Modbus communication for seamless integration into energy monitoring systems.
Key Features:
  • Direct Connection: ULYS MD45 supports up to 45 A, while ULYS MD100 supports up to 100 A.
  • Communication: Both models feature RS485 Modbus communication for remote data access.
  • Dual-Tariff Metering: Supports two-way, dual-tariff metering for fair rebilling of consumption.
  • Customizable Display: The meters offer customizable screen scrolling with different display lines for comprehensive information.
  • Touch-Sensitive Navigation: Easy navigation and parameter settings via touch-sensitive keys.
Technical Specifications:
  • Voltage Input: 230 Vac with a tolerance of -15% to +10%.
  • Frequency: 50 Hz ± 10%.
  • Pulse Output: Various pulse output configurations for kWh consumed and generated.
  • Accuracy: MID Class B certified for active energy metering.
  • Environmental Conditions: Operating temperature range from -25°C to +55°C, storage temperature from -40°C to +70°C, and suitable for indoor use up to 2000 m altitude.
Applications: The ULYS submeters are suitable for various applications including marinas, data centers, infrastructure, industry, and tertiary sectors.
Additional Solutions: The document mentions additional products like Eonline3 for energy monitoring, MEMO meters for housing applications, and ELOG Data Logger for remote data retrieval.
Contact Information: The document provides contact details for Chauvin Arnoux Energy offices in France, the Middle East, and the United Kingdom.
See more

Catalog excerpts

ULYS MD45 & ULYS MD100-1

Single-phase, direct connection up to 100 A Built-in RS485 Modbus communication Two-way, dual-tariff metering

 Open the catalog to page 1
ULYS MD45 & ULYS MD100-2

ULYS submeters range The ideal solution for fair rebilling of electrical power consu single-phase network. A solution compliant with the latest regulations Suitable for monitoring all your different uses (lighting, sanitary hot water, heating, etc.) Fair rebilling of consumption MID, double tariff, partial metering Easy start-up Built-in Modbus communication Optimized display Navigation and parameter settings by means of touchsensitive keys Quick, simple integration on your single-phase feeders Totally customizable screen scrolling For remote access to all the measured values in a compact unit...

 Open the catalog to page 2
ULYS MD45 & ULYS MD100-3

MULTI-MEASUREMENT (V, I, P, Q, S, F, PF) With local or remote access (RS485 Modbus), for instantaneous display of the electrical quantities on your feeder. Data center / Infrastructure Mandatory for rebilling active energy on the basis of consumption data calculated by the index difference. Chauvin Arnoux Energy's active energy meters are MID-certified. Their names include the indication "-M", like the ULYS MD45-M Industry / Tertiary

 Open the catalog to page 3
ULYS MD45 & ULYS MD100-4

Single-phase network Rated maximum current (Imax) Minimum current(Imin) Inrush current (Ist) Voltage input Consumption Frequency Metrological LED Number of pulse outputs Weight of pulse output 10,000 pulses/kWh/kvarh 2 (kWh import / export) 10,000/2,000/1,000/100/10/1/0.1/0.01 pulses/kWh 1,000/100/10/1/0.,1/0.01 pulses/kWh 31 ms 2,000 pulses/kWh ≤ 30 kW 1,0000 pulses/kWh ≤ 6 kW Max. operating voltage Max. operating current Tariff change input Accuracy class Communication Data storage MULTI-MEASUREMENT Active energy values Reactive energy values Multi-measurement DISPLAY ≤ 27 mAdc 0 V = T1 230...

 Open the catalog to page 4

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4  Pages

  2. TC CLIP

    2  Pages

  3. PROBIX

    4  Pages

  4. OX9302-BUS

    4  Pages

  5. C.A 6255

    4  Pages

  6. CA 6165

    4  Pages

  7. CBF01

    2  Pages

  8. MX 604

    2  Pages

  9. MX 409

    4  Pages

  10. CA 6528

    4  Pages

  11. MX 535

    4  Pages

  12. CA 6011

    4  Pages

  13. C.A 6418

    2  Pages

  14. PAC Series

    4  Pages

  15. ASYC IV

    8  Pages

  16. SCOPIX IV

    8  Pages

  17. MEMO P200

    2  Pages

  18. GRIDWATCH

    6  Pages

  19. ULYS MCM

    4  Pages

  20. C.A 7028

    3  Pages

  21. HypeReal

    4  Pages

  22. THYRITOP 600

    4  Pages

  23. THYRITOP 500

    3  Pages

  24. THYRITOP 200

    2  Pages

  25. THYRITOP 100

    2  Pages

  26. CA 8345

    12  Pages

  27. CA 8220

    4  Pages

  28. C.A 847

    1  Page

  29. C.A 895

    2  Pages

  30. C.A 1950

    4  Pages

  31. CA 1954

    4  Pages

  32. CA 1310

    2  Pages

  33. CA 1900

    2  Pages

  34. C.A 5011

    2  Pages

  35. F65

    4  Pages

  36. CA 6292

    4  Pages

  37. C.A 6240

    2  Pages

  38. C.A 6630

    2  Pages

  39. C.A 6121

    4  Pages

  40. CA 1550

    2  Pages

  41. C.A 1510

    4  Pages

  42. CA 1227

    2  Pages

  43. C.A 1110

    2  Pages

  44. C.A 1246

    2  Pages

  45. C.A40

    2  Pages

  46. CA 10141

    4  Pages

  47. C.A 10101

    4  Pages

  48. C.A 10001

    2  Pages

  49. CA 10002

    2  Pages

  50. VASD 40

    2  Pages

  51. DIGITAL RANGE

    4  Pages

  52. C.A 745N

    2  Pages

  53. CA 6651

    2  Pages

  54. MX 531

    2  Pages

  55. C.A 6470N

    4  Pages

  56. E Series

    8  Pages

  57. E25 & E27

    2  Pages

  58. B100 series

    4  Pages

  59. MH SERIES

    5  Pages

  60. DN SERIES

    15  Pages

  61. K SERIES

    4  Pages

  62. C100 series

    18  Pages

  63. YN SERIES

    9  Pages

  64. MN SERIES

    16  Pages

  65. MINI series

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.