THYRITOP 700 SERIES-1

Power controllers 4 PID loops from 16A to 40A 3-in-1 solution Simple and intuitive Ratings from 16A to 40A 4 single-phase zones or 1 three-phase zone Fieldbus communication

 Open the catalog to page 1
THYRITOP 700 SERIES-2

Fault detection • If the sensor breaks or if it is connected incorrectly • Total or partial breaking of the load • Variable outside range and abnormal variable • Overheating on power unit Main application sectors ♦ Industrial furnaces for metallurgical and heat treatments ♦ Industrial dryers ♦ Thermoforming machine ♦ Extrusion line ♦ Heating system with infrared lamps (long medium and short wave) ♦ Machine for

 Open the catalog to page 2
THYRITOP 700 SERIES-3

| IDEAL SOLUTION FOR RESISTIVE LOADS Compact solution Combination of a 4-loop controller and 4 solid-state contactors Simple configuration Thanks to the processing software Quick, accurate adjustment Sampling interval customizable to 120 or 60ms Built-in fuse Ultra-fast fuse Optimization of the settings Advanced tuning algorithms | IDEAL SOLUTION FOR COMPLEX LOADS Compact, all-in-one solution Combination of a 4-loop controller and 4 power controllers Adapts to all types of load Super Kantal – short infrared - Resistive – Silicon carbide - Inductive Control of electrical quantities Control of...

 Open the catalog to page 3
THYRITOP 700 SERIES-4

| TECHNICAL SPECIFICATIONS THYRITOP 704 Input CT input RTD input Main input IN1 to IN4 Thermocouple: J,K,R,S,T; Linearization: ITS90 Cold junction compensation error 0.1°C Pt100 linearization: DIN 43760, maximum line resistance: 20Ω It is possible to insert 32-segment custom linearization Sampling interval It is possible to insert 32-segment custom linearization OUT1 to OUT4 heat control outputs, directly linked to the solid-state relays Configurable (heat control by default) The status of the command is indicated by diodes (O1,…,O2) Baud rate Communication ports PORT 1 Node address Rated voltage...

 Open the catalog to page 4
THYRITOP 700 SERIES-5

tools SOFTWARE | CUSTOMIZATION AND ADVANCED PARAMETER SETTINGS A clever, simple tool for: • Configuration of the parameters • Display of the data and analysis of the parameters: measured values, set points, alarms, etc. • Recording of the data • Archiving Available for download from The cable connecting the PC and the Thyritop 700/714 (for configuration) is sold separately. Don't forget to order it. | EXAMPLE OF CONNECTION WITH 4 SINGLE-PHASE LOADS THREE-PHASE LINE WITHOUT NEUTRAL P Id = ______ Vcosɸ V = line voltage Id = current in the load P = total power If resistive load, cosɸ = 21

 Open the catalog to page 5
THYRITOP 700 SERIES-6

| TO ORDER THYRITOP 704 Assembly 906211683 - Ed. 1 - 04/2022 – LC - Document non contractuel. Caractéristiques sous réserve de modifications liées à l’évolution de la technologie. Four-phase resistive load control Tension 480V Rated power (kW) Four-phase resistive load control 480V voltage Rated power (kW) * Short infrared load, current to be divided by 2 and inductive load, value to be divided by 1.5 Contact CA Pyrocontrole for more information Detection of partial or total load break A wide range of accessories is available: fuses, configuration cables, software, etc. Contact us: PYROCONTROLE...

 Open the catalog to page 6

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4  Pages

  2. TC CLIP

    2  Pages

  3. PROBIX

    4  Pages

  4. OX9302-BUS

    4  Pages

  5. C.A 6255

    4  Pages

  6. CA 6165

    4  Pages

  7. CBF01

    2  Pages

  8. MX 604

    2  Pages

  9. MX 409

    4  Pages

  10. CA 6528

    4  Pages

  11. MX 535

    4  Pages

  12. CA 6011

    4  Pages

  13. C.A 6418

    2  Pages

  14. PAC Series

    4  Pages

  15. ASYC IV

    8  Pages

  16. SCOPIX IV

    8  Pages

  17. MEMO P200

    2  Pages

  18. GRIDWATCH

    6  Pages

  19. ULYS MCM

    4  Pages

  20. C.A 7028

    3  Pages

  21. HypeReal

    4  Pages

  22. THYRITOP 600

    4  Pages

  23. THYRITOP 500

    3  Pages

  24. THYRITOP 200

    2  Pages

  25. THYRITOP 100

    2  Pages

  26. CA 8345

    12  Pages

  27. CA 8220

    4  Pages

  28. C.A 847

    1  Page

  29. C.A 895

    2  Pages

  30. C.A 1950

    4  Pages

  31. CA 1954

    4  Pages

  32. CA 1310

    2  Pages

  33. CA 1900

    2  Pages

  34. C.A 5011

    2  Pages

  35. F65

    4  Pages

  36. CA 6292

    4  Pages

  37. C.A 6240

    2  Pages

  38. C.A 6630

    2  Pages

  39. C.A 6121

    4  Pages

  40. CA 1550

    2  Pages

  41. C.A 1510

    4  Pages

  42. CA 1227

    2  Pages

  43. C.A 1110

    2  Pages

  44. C.A 1246

    2  Pages

  45. C.A40

    2  Pages

  46. CA 10141

    4  Pages

  47. C.A 10101

    4  Pages

  48. C.A 10001

    2  Pages

  49. CA 10002

    2  Pages

  50. VASD 40

    2  Pages

  51. DIGITAL RANGE

    4  Pages

  52. C.A 745N

    2  Pages

  53. CA 6651

    2  Pages

  54. MX 531

    2  Pages

  55. C.A 6470N

    4  Pages

  56. E Series

    8  Pages

  57. E25 & E27

    2  Pages

  58. B100 series

    4  Pages

  59. MH SERIES

    5  Pages

  60. DN SERIES

    15  Pages

  61. K SERIES

    4  Pages

  62. C100 series

    18  Pages

  63. YN SERIES

    9  Pages

  64. MN SERIES

    16  Pages

  65. MINI series

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.