THYRITOP 700 SERIES - 1

Power controllers 4 PID loops from 16A to 40A 3-in-1 solution Simple and intuitive Ratings from 16A to 40A 4 single-phase zones or 1 three-phase zone Fieldbus communication

Open the catalog to page 1
THYRITOP 700 SERIES - 2

Fault detection • If the sensor breaks or if it is connected incorrectly • Total or partial breaking of the load • Variable outside range and abnormal variable • Overheating on power unit Main application sectors ♦ Industrial furnaces for metallurgical and heat treatments ♦ Industrial dryers ♦ Thermoforming machine ♦ Extrusion line ♦ Heating system with infrared lamps (long medium and short wave) ♦ Machine for

Open the catalog to page 2
THYRITOP 700 SERIES - 3

| IDEAL SOLUTION FOR RESISTIVE LOADS Compact solution Combination of a 4-loop controller and 4 solid-state contactors Simple configuration Thanks to the processing software Quick, accurate adjustment Sampling interval customizable to 120 or 60ms Built-in fuse Ultra-fast fuse Optimization of the settings Advanced tuning algorithms | IDEAL SOLUTION FOR COMPLEX LOADS Compact, all-in-one solution Combination of a 4-loop controller and 4 power controllers Adapts to all types of load Super Kantal – short infrared - Resistive – Silicon carbide - Inductive Control of electrical quantities Control...

Open the catalog to page 3
THYRITOP 700 SERIES - 4

| TECHNICAL SPECIFICATIONS THYRITOP 704 Input CT input RTD input Main input IN1 to IN4 Thermocouple: J,K,R,S,T; Linearization: ITS90 Cold junction compensation error 0.1°C Pt100 linearization: DIN 43760, maximum line resistance: 20Ω It is possible to insert 32-segment custom linearization Sampling interval It is possible to insert 32-segment custom linearization OUT1 to OUT4 heat control outputs, directly linked to the solid-state relays Configurable (heat control by default) The status of the command is indicated by diodes (O1,…,O2) Baud rate Communication ports PORT 1 Node address Rated...

Open the catalog to page 4
THYRITOP 700 SERIES - 5

tools SOFTWARE | CUSTOMIZATION AND ADVANCED PARAMETER SETTINGS A clever, simple tool for: • Configuration of the parameters • Display of the data and analysis of the parameters: measured values, set points, alarms, etc. • Recording of the data • Archiving Available for download from The cable connecting the PC and the Thyritop 700/714 (for configuration) is sold separately. Don't forget to order it. | EXAMPLE OF CONNECTION WITH 4 SINGLE-PHASE LOADS THREE-PHASE LINE WITHOUT NEUTRAL P Id = ______ Vcosɸ V = line voltage Id = current in the load P = total power If resistive load, cosɸ = 21

Open the catalog to page 5
THYRITOP 700 SERIES - 6

| TO ORDER THYRITOP 704 Assembly 906211683 - Ed. 1 - 04/2022 – LC - Document non contractuel. Caractéristiques sous réserve de modifications liées à l’évolution de la technologie. Four-phase resistive load control Tension 480V Rated power (kW) Four-phase resistive load control 480V voltage Rated power (kW) * Short infrared load, current to be divided by 2 and inductive load, value to be divided by 1.5 Contact CA Pyrocontrole for more information Detection of partial or total load break A wide range of accessories is available: fuses, configuration cables, software, etc. Contact us:...

Open the catalog to page 6

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4 Pages

  2. TC CLIP

    2 Pages

  3. PROBIX

    4 Pages

  4. OX9302-BUS

    4 Pages

  5. C.A 6255

    4 Pages

  6. CA 6165

    4 Pages

  7. CBF01

    2 Pages

  8. MX 604

    2 Pages

  9. MX 409

    4 Pages

  10. CA 6528

    4 Pages

  11. MX 535

    4 Pages

  12. CA 6011

    4 Pages

  13. C.A 6418

    2 Pages

  14. PAC Series

    4 Pages

  15. ASYC IV

    8 Pages

  16. SCOPIX IV

    8 Pages

  17. MEMO P200

    2 Pages

  18. GRIDWATCH

    6 Pages

  19. ULYS MCM

    4 Pages

  20. C.A 7028

    3 Pages

  21. HypeReal

    4 Pages

  22. THYRITOP 600

    4 Pages

  23. THYRITOP 500

    3 Pages

  24. THYRITOP 200

    2 Pages

  25. THYRITOP 100

    2 Pages

  26. CA 8345

    12 Pages

  27. CA 8220

    4 Pages

  28. C.A 847

    1 Pages

  29. C.A 895

    2 Pages

  30. C.A 1950

    4 Pages

  31. CA 1954

    4 Pages

  32. CA 1310

    2 Pages

  33. CA 1900

    2 Pages

  34. C.A 5011

    2 Pages

  35. F65

    4 Pages

  36. CA 6292

    4 Pages

  37. C.A 6240

    2 Pages

  38. C.A 6630

    2 Pages

  39. C.A 6121

    4 Pages

  40. CA 1550

    2 Pages

  41. C.A 1510

    4 Pages

  42. CA 1227

    2 Pages

  43. C.A 1110

    2 Pages

  44. C.A 1246

    2 Pages

  45. C.A40

    2 Pages

  46. CA 10141

    4 Pages

  47. C.A 10101

    4 Pages

  48. C.A 10001

    2 Pages

  49. CA 10002

    2 Pages

  50. VASD 40

    2 Pages

  51. C.A 745N

    2 Pages

  52. CA 6651

    2 Pages

  53. MX 531

    2 Pages

  54. C.A 6470N

    4 Pages

  55. E Series

    8 Pages

  56. E25 & E27

    2 Pages

  57. B100 series

    4 Pages

  58. MH SERIES

    5 Pages

  59. DN SERIES

    15 Pages

  60. K SERIES

    4 Pages

  61. C100 series

    18 Pages

  62. YN SERIES

    9 Pages

  63. MN SERIES

    16 Pages

  64. MINI series

    12 Pages

Archived catalogs

  1. PANEL METERS

    4 Pages

  2. T82N

    12 Pages

  3. ELINK 61850

    2 Pages

  4. Handscope

    4 Pages