Analog transducers
Open the catalog to page 1T82N Range Analog transducers for AC electrical quantities, class 0.5 PRODUCT ADVANTAGES I deal for the requirements of the NUCLEAR MARKET PLATE-MOUNTED AND PLUG-IN versions CONFIGURABLE ON REQUEST: Input quantities, transfer curve, output signal, etc. Plug- in version with special socket for plate mounting or DIN rail mounting The T82N models measure an AC electrical quantity and converts it into a standardized, low-level DC current or voltage signal (e.g. 4...20 mA). They are normally used in conjunction with analog or digital measuring instruments (panel meters, recorders, etc.), supervision...
Open the catalog to page 3T82N Range > Electrical specifications ■ Inputs • Short-term overload: U input: 2 Un during 1s repeated 10 times I input: 20 In during 1s repeated 10 times • C overload : D U input: 1.2 Un I input: 1.2 Un ■ Auxiliary power supply: • perating range: O ± 10 % from 100/√3 Vac to 440 Vac ± 20 % from 24 to 125 Vdc • onsumption : C ≤ 3 VA from 100/√3 to 440 Vac ≤ 3 W from 24 to 125 Vdc • Frequency: 50 Hz (45….55 Hz) 60 Hz (55….65 Hz) ■ Analog output • ccuracy: class 0.5 according to IEC 60688 April 2013 A • esponse time: 120 ms to 260 ms at 95 % of output R current • Current output operating resistance:...
Open the catalog to page 4STANDARDBoîtier T82 MODULE BOITIER STANDARD BOITIER STANDARD Plug-in T82N plug-in module Boîtier T82 embrochable Plug-in module Boîtier Embrochable Safety socket Embase de sécurité Détrompeur Safety blank Dégagement clearance Boîtier Embrochable
Open the catalog to page 5T82N Range > Mounting accessories ■ Connection socket for plug-in module Socket Model Type Reference UAR 1210B 5 EMBB 4005 IAR 1210B 4 EMBB 4004 PAR 1232B 3 EMBB 4003 QAR 1232B 3 EMBB 4003 ■ Mounting on DIN rail for plate-mounting or plug-in module Model Mounting on symmetrical DIN rail Mounting on asymmetrical DIN rail Reference PDIN SYME PDIN ASYM > Electrical connections See document MS 0/1-7343.
Open the catalog to page 6RMS AC voltage VAC Model Transfer curve Linear Module Plate-mounting Measurement input Voltage Un Frequency Fn Measurement range 0…Xmax Consumption Analog output Current Voltage Accuracy Auxiliary supply Alternating current Direct current Module protection rating Plate-mounting > Customized product Model Direct Un or on VT Measurement range Direct 100 Vac > Associated products Normeurope analog panel meters Sockets for plug-in modules Analog output Auxiliary supply
Open the catalog to page 7T82N Range AC RMS voltage IAC Model Transfer curve Linear Module Plate-mounting Measurement input Current In Frequency Fn Measurement range 0…Xmax Consumption Analog output Voltage Accuracy Auxiliary supply Alternating current Direct current Module protection rating Plate-mounting > Customized product Model Measurement range Analog output Auxiliary supply > Associated products Normeurope analog panel meters Sockets for plug-in modules
Open the catalog to page 8Active power P Model Network + connections Balanced three-phase - 3 wires Unbalanced three-phase - 3 / 4 wires Transfer curve Linear Module Plate-mounting Module Current In Ph-N voltage Un Ph-Ph voltage Un Frequency Fn Measurement range 0…Xmax Consumption Analog output 0…Ymax Current Accuracy Auxiliary supply Alternating current Direct current Module protection rating Plate-mounting (1) Sn = V x I x cos ϕ (single-phase network) Sn = 3 x V x I x cos ϕ (Balanced three-phase, Unbalanced three-phase 4 wires) Sn = √3 x U x I x cos ϕ (Balanced three-phase, Unbalanced three-phase 3 wires) > Customized...
Open the catalog to page 9T82N Range Reactive power Q Model Network + connections Balanced three-phase - 3 wires Unbalanced three-phase - 3 / 4 wires Transfer curve Linear Module Plate-mounting Measurement input Current In Ph-N voltage Un Ph-Ph voltage Un Frequency Fn Measurement range 0…Xmax Consumption Analog output 0…Ymax Current 0,7 kg Direct or on CT : "1" "5" "10" Direct or on VT "57.73" "63.51" "66.4" "230" Direct or on VT "100" "110" "115" "120" "127" "230" "240" "380" "400" 50 Hz ±5 Hz and 60 Hz ±5 Hz ±1.35 ≥Sn(1) ≥ ±0.50 I input: ≤ 0.2 VA ; U input: ≥ 500 Ω/ V "0/1 mA" "0/2.5 mA" "0/5 mA" "0/10 mA" "0/20 mA"...
Open the catalog to page 10ENERDIS is the company specialized in fixed equipment for measurement, testing, metering and supervision of electrical networks, as well as energycontrol solutions for all utilities. The company joined the CHAUVIN ARNOUX Group in 1998, benefiting from the global R&D teams integrated production facilities to offer comprehensive expertise covering everything from electrical measurement through to energy performance. 10 FILIALES DANS LE MONDE SUISSE CHAUVIN ARNOUX AG Moosacherstrasse 15 8804 AU / ZH Tél. : +41 44 727 75 55 Fax : +41 44 727 75 56 [email protected] www.chauvin-arnoux.ch USA Chauvin...
Open the catalog to page 122 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
4 Pages
6 Pages
3 Pages
2 Pages
6 Pages
4 Pages
8 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
12 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
4 Pages
4 Pages
36 Pages
4 Pages
8 Pages
8 Pages
2 Pages
4 Pages
17 Pages
5 Pages
15 Pages
4 Pages
18 Pages
9 Pages
16 Pages
12 Pages
13 Pages
16 Pages
4 Pages
4 Pages
12 Pages
336 Pages
154 Pages
4 Pages
2 Pages
4 Pages
4 Pages
8 Pages
2 Pages
4 Pages
64 Pages