SIMPLE LOGGER® II For effective analysis of your network, the Simple Logger® II records everything! Data Loggers AC Current AC Voltage DC Current DC Voltage Temperature Relative humidity ► rogrammable storage modes P ► rogrammable storage rates P ► tores up to 240,000 measurements S ► uns on alkaline batteries R ► ptically-isolated USB port O ► ncludes DataView® graphing, I analysis and report generation software ► isplay and analyse real-time dat
Open the catalog to page 1Data Logging Made Simple… Simple Logger ® II FEATURES ► rue RMS measurements provide an T accurate representation of measured signals for AC models ► hoice of data storage modes to assist C in matching the data collection to the application needs ► tores over 240,000 measurements, S ensuring that no valuable data is missed; (more than 8 hours at 8 samples per second; approximately 1 week at one sample every 2 seconds) ► ompact size and battery operation C ► uick and easy to install anywhere, Q operational in seconds ► isplay and analyse real-time data through D your PC L562 monitoring...
Open the catalog to page 2Simple Logger® II DataView® software provides a convenient way to configure and control power analysis tests from your computer. Through the use of clear and easy-to-use tabbed dialogue boxes, all Simple Logger® II functions can be configured and tests can be initiated. Results can be displayed in real time and stored in your PC or the logger. Reports may be printed along with the operator’s comments and analysis. DataView® is included with all Simple Logger® II models. ► isplay and analyse real-time data on your PC D ► ecord real-time to your PC R ► onfigure all data logger functions and C...
Open the catalog to page 3applications MONITORING THE TEMPERATURE OF A ROTARY FURNACE To prevent possible damage to the equipment, avoid unscheduled production shutdowns and simultaneously cut costs, it is a good idea to monitor furnace operation. Such monitoring means implementing a Process system which continuously measures the furnace temperature and automatically detects any changes. On any 4-20 logger, the 4 mA level corresponds to the furnace’s minimum temperature, while the 20 mA level represents the maximum temperature. Sensors equipped with a 4-20 mA output are directly compatible with most control systems....
Open the catalog to page 4Simple Logger® II TRMS Clamp-on current model CL601 ATION ER Model CL601 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. ► to 600 Arms 0 ► rue RMS AC measurements T ► elf-contained, no exposed connections S ► verload indication O ► ptically-isolated USB 2.0 output (cable included) O ► ne-button operation O ► larm function A ► LED indicators display logger status quickly and 5 clearly ► ncludes FREE DataView® software for data I storage, real-time display, analysis and report generation ► SB cable included U SPECIFICATIONS Model...
Open the catalog to page 5Simple Logger® II TRMS Current model L101 RE P O IC Model L101 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Probes sold separately. Model L101 0.1 mV 0 to 10 mV: unspecified Accuracy (50/60 Hz) 10 to 50 mV: ±(0.5 % R + 1 mV) 50 to 1 000 mV: ±(0.5 % R + 0.5 mV) Sample rate 64 samples/cycle Storage rate Programmable from 125 ms to 1 day Storage modes Start/Stop, FIFO and Extended Recording Mode (XRM™) Recording length 15 minutes to 8 weeks, programmable using DataView® 240,000 measurement (512 kB). The recorded data is stored in...
Open the catalog to page 6Simple Logger® II TRMS Current model L102 RE P O IC Model L102 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Probes sold separately. Model L102 SPECIFICATIONS Model ELECTRICAL SPECIFICATIONS Channels Input connection Current-probe output-voltage range Resolution L102 2 One BNC connector per channel 0 to 1 Vac (depending on probe) 0.1 mV 0 to 10 mV: unspecified Accuracy (50/60 Hz) 10 to 50 mV: ±(0.5 % R + 1 mV) 50 to 1000 mV: ±(0.5 % R + 0.5 mV) Sample rate 64 samples/cycle Storage rate Programmable from 125 ms to 1 day Storage...
Open the catalog to page 7Simple Logger® II TRMS Current model L111 RE P O IC Model L111 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Probes sold separately. Model L111 SPECIFICATIONS Model ELECTRICAL SPECIFICATIONS Channels Input connection Current-probe output-current range Resolution Accuracy (50/60 Hz) Sample rate Storage rate Storage modes Recording length Memory Communication Power source Battery life MECHANICAL SPECIFICATIONS Dimensions Max conductor size Weight (with battery) Safety rating Casing Vibration Shock Drop ENVIRONMENTAL SPECIFICATIONS...
Open the catalog to page 8Simple Logger® II TRMS Current model ML912 RE P O IC Line tracking is performed at a rate of 64 samples per line cycle. Frequency tracking is performed over a range of ±2 Hz around the nominal line frequency (50 or 60 Hz). Harmonic measurements are calculated from the 64 samples (available in DataView®). The Simple Logger® II stores TRMS values at user-programmable rates of up to eight times per second. TRMS calculations are performed on a single line cycle. Model ML912 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Probes sold...
Open the catalog to page 9Simple Logger® II TRMS 600 Vac/dc model L261 RE P O IC Model L261 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Model L261 ► RMS voltage recording up to 600 V ac/dc T ► 4 samples per cycle 6 ► rogrammable storage rates from 8 per second P to 1 per day ► user-selectable storage modes 3 ► tores up to 240,000 measurements in nonS volatile memory ► owered by standard alkaline batteries P ► ightweight, compact, fits anywhere L ► LED indicators display logger status quickly 5 and clearly ► ncludes FREE DataView® software for data I...
Open the catalog to page 10Simple Logger® II Voltage/Current model L562 RE P O IC Model L562 includes type A to 5-pin mini-B USB 2 m, DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual. Probes sold separately. Model L562 SPECIFICATIONS Model ELECTRICAL SPECIFICATIONS Channels Connection Input connection Voltage range Resolution Current channel Voltage channel BNC 2 recessed banana jacks 0 to 1 Vac* 0 to 600 Vac 0.1 mA 0.1 V 0 to 5 V: unspecified 0 to 10 mV: unspecified Accuracy (50/60 Hz) 5 to 50 V: ±(0.5 % R + 1 V) 10 to 50 mV: ±(0.5 % R + 1 mV) 50 to 600 V: ±(0.5 % R + 0.5 V) 50 to 1000 mV: ±(0.5 %...
Open the catalog to page 11All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages