Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
OSCILLOSCOPES WITH ISOLATED CHANNELS good reasons to choose a Oscilloscope, multimeter, analyser and recorder modes, with the recorded files directly viewable on the oscilloscope. Safety: channels genuinely isolated from one another and from the earth, 600 V CAT III & Probix probes Ergonomics: modern, hi-tech environment for oscilloscopes which are simple, compact and practical Optimization of all the tools: communication, storage and operation METRIX® expertise applied to all the modes: bandwidth, sampling, memory, etc.
Open the catalog to page 1The ergonomics of the SCOPIX IV portable oscilloscopes has been designed to simplify their use. In a casing tailor-made to be as compact as possible, the external mechanical design of the SCOPIX IV makes it possible to integrate the hardware components in a very small volume, while the keypad benefits from a new technology developed in the automotive industry. Identification of the channels and parameters Each channel and the related parameters can be identified because they have an identical colour against a black background for simpler, quicker viewing. Easy access via the touch screen...
Open the catalog to page 2APPLICATIONS IP54 Casing protected against dust and water droplets Electronic maintenance The OX 9304 model is ideal for electronics with its 300 MHz bandwidth, 4 x 600 V CAT III isolated channels, advanced trigger functions, integrated FFT function, complex mathematical calculations on the curves, automatic measurements on 4 channels and the built-in WEB server. 7’’ WVGA wide colour TFT touch screen This makes it easy to view and read the signals clearly. It also provides a screen resolution of 800 x 480 dpi with manual or automatic brightness. Space for stowing the touch-screen stylus...
Open the catalog to page 3PROBIX ACCESSORIES The accessories The “plug and play” accessories are recognized automatically when they are connected. This means they can be implemented quickly and in total safety. It is also possible to connect BNC accessories and standard banana leads with the safety adapters supplied. Interchangeable coloured collars can be used to link each accessory to the colour of its channel. The sensors are powered and calibrated via the oscilloscope. Some accessories even include three control buttons directly accessible on the probe to optimize your settings without any bother. Identification...
Open the catalog to page 4Communication isolated from the measurements for interfacing in total safety Multiple communication interfaces You can choose the type of communication to fit your requirements: APPLICATIONS Electrical cabinet XX Wired ETHERNET LAN network with integrated DHCP server for easy connection to your network, with the possibility of activating the WiFi radio link to communicate with a PC, tablet or smartphone using the dedicated interfaces. XX USB for interfacing with a PC: record, recall or load configurations. XX µSD > 8 GB, default storage, given priority over the 1 GB internal memory. File...
Open the catalog to page 5OSCILLOSCOPE MULTIMETER ANALYSER RECORDER The functions and performance levels of the SCOPIX IV have been improved: XX wider bandwidth up to 300 MHz XX new possibilities for triggering and recording XX increased storage capacity And many other advantages... Oscilloscope: trigger functions, automatic measurements, MATH functions An OSCILLOSCOPE with complex trigger functions so that you only record what is necessary, while capturing all the faults. The OX 9000 models offer advanced triggers which complement the main edge trigger options: pulse width, counting, delay. XX The Delay mode...
Open the catalog to page 6Harmonic analysis is performed on all 4 channels up to the 63rd order to comply with the requirements of the EN 50160 standard (THD on 50 orders minimum), with a fundamental frequency between 40 and 450 Hz. It is possible to preselect the frequency of the fundamental for the standards (50 Hz, 60 Hz and 400 Hz). This function helps to improve analytical performance and, above all, measurement when the level of a harmonic order is greater than the fundamental. It is possible to view the harmonic analyses of two or four channels simultaneously: RMS level, harmonic distortion, harmonic...
Open the catalog to page 7TECHNICAL SPECIFICATIONS HUMAN-MACHINE INTERFACE Type of display 7‘’ WVGA colour TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode) Different display mode 2,500 real acquisition points on screen - Vectors with interpolation Display of curves on screen 4 curves + 4 references – Split Screen & Full Screen modes Screen commands Touch screen – ANDROID-type icons and graphical commands – customizable channel colours 15 complete languages, menus & online help OSCILLOSCOPE MODE Vertical deflection 60 MHz Input impedance 4 isolated channels 1 MΩ ± 0.5% , approx. 12 pF...
Open the catalog to page 8All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages