PEL 100 SERIES Power and energy loggers, simultaneously PEL100, the loggers for efficient consumption! y Ideal for all types of electrical cabinets and Low Voltage installations Implementation without cutting off the mains power supply Recording duration up to several months or years Breakdown of energy losses
Open the catalog to page 1In the context of a worldwide approach for protection of the environment, Europe has set itself the goal of reducing consumption by approximately 30%. Today, more than 50% of energy consumption occurs in the industrial sector and buildings. Optimization of energy consumption is therefore crucial to fulfil the regulatory requirements. PEL100 loggers catch every detail of the electrical consumption in a factory, workshop, building, agency, etc. They can be used simultaneously for real-time monitoring and comparative, historical consumption analysis. or sustainable, economical buildings, improve...
Open the catalog to page 2nalogue measurements The PEL106 can be used to identify each of the dysfunctions by recording external parameters such as the pressure, temperature etc. Via its Bluetooth wireless link, it communicates with remote L452 dataloggers. The PEL106’s recording function can integrate up to 2 x 4 analogue channels. The analogue channels complement the voltage, current and power measurements. Energy consumption of a transformer station, etc. When used with remote L452 loggers, the PEL106 records analogue measurements (external parameters, up to 2 x 4 channels) such as the temperature, pressure, etc. It...
Open the catalog to page 3ALL THE PEL100 MODELS ARE EQUIPPED WITH MULTIPLE COMMUNICATION MODES: ETHERNET AND USB PORTS, AS W The PEL104 and PEL106 also offer Wifi communication and 3G/GPRS. The 3G/GPRS mode allows users to insert a SIM card in the PEL for remote co automatically receive an email for real-time notifications. By positioning PEL100s on the different electrical feeders, it is possible and even simple to size the relative weight of each line in terms of overall consumption, define a load profile for the installation and thus determine the priorities for the improvements to be made. When access to the PEL100...
Open the catalog to page 4onnection via a GPRS-3G link. It is also possible to access a PEL104 or PEL106 via an IRD server. In this way, when an alarm is triggered, the user can Bluetooth enables the PEL100 models to communicate with a smartphone or gain access to the analogue channels. When possible, the PEL100 models can be connected together by means of an Ethernet-type wire link. Verification of the connections and real-time display of the measurements
Open the catalog to page 5Total energy Partial energy easurements & functions The PEL100 power and energy loggers perform the following measurements: RMS and DC measurements with 128 samples/cycle – simultaneously on each phase AC and/or DC voltages up to 1,000 V Analogue measurements Measurements on motors Self-powering via the phase Current up to 10 kA AC or 5 kA DC (depending on the current sensor). The PEL100 models offer a wider measurement range by using voltage and current ratios (up to 650,000 V / 25,000 A) Power values from 10 W/var/VA to 10 GW/Gvar/GVA Energy values up to 4 EWh / 4 EVAh / 4 Evarh & total energy...
Open the catalog to page 6This application software lets you: Configure the PEL100 Check the connections before starting to record Download the measurements recorded in the PEL100 View the various measurement results and analyses With the comprehensive DataView® processing software, it is also possible to create certified or customized reports. In this way, DataView® helps you to generate your energy consumption reports more easily. Our PEL Transfer software performs mathematical processing on the power measurement campaigns and automatically breaks down all the losses detected. urrent sensors compatible with the PEL...
Open the catalog to page 7SPECIFICATIONS Models Display Types of installations Number of channels PEL104 PEL106 With quadruple digital display Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations 3 voltage inputs, 3 current inputs (calculated neutral current) 4 voltage inputs, 4 current inputs Measurements Network frequency Voltage (measurement ranges) Current (depending on sensors) (measurement ranges) Calculated measurements Ratio Power Energy Phase Harmonics Additional functions Phase sequence Min / Max Mounting Recording Sampling / Acquisition interval / Aggregation...
Open the catalog to page 82 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
4 Pages
6 Pages
3 Pages
2 Pages
6 Pages
4 Pages
8 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
12 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
4 Pages
4 Pages
36 Pages
4 Pages
8 Pages
8 Pages
2 Pages
4 Pages
17 Pages
5 Pages
15 Pages
4 Pages
18 Pages
9 Pages
16 Pages
12 Pages
13 Pages
16 Pages
4 Pages
4 Pages
12 Pages
336 Pages
154 Pages
4 Pages
2 Pages
4 Pages
12 Pages
4 Pages
8 Pages
2 Pages
4 Pages
64 Pages