video corpo

MX 5006, MX 5060
3Pages

{{requestButtons}}

Catalog excerpts

MX 5006, MX 5060 - 1

TECHNICAL SPECIFICATIONS DC, AC and AC+DC current Range Resolution* DC accuracy AC and AC+DC bandwidth AC and AC+DC accuracy Frequency Frequency range Resolution* Resistance and continuity Range Resolution* Basic accuracy Protection Audible continuity detection Diode test Voltage measurement Capacitances Range Resolution K thermocouple temperature Operating range Accuracy / Resolution Other functions Min/Max/Peak ± ΔREL PWM filter Central Zero USB communication Measurement rate and bargraph General specifications Display type 1,000 V electronic protection 600 Ω SIGNAL <30 Ω +/-5 Ω < 5V 3 V, resolution 1 mV + Buzzer <40 mV ±10 mV 6 nF 0.001 nF -200 °C to +1,200 °C 0.5% R / 0.1 °C On all positions measured MEM relative value on secondary display subtracted from the measured value on the main display 4th-order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors VDC and IDC with central zero With SX-DMM2 software – SCPI commands 5 measurements per second and 61-segment bargraph for analogue function PC interfaces Mains power supply Safety / EMC Environment Mechanical specifications Warranty Transflective LCD with backlighting, broadened viewing angle and 16 mm digits 60,000-count* or 6,000-count double display USB type B connector – SX-DMM2 software Universal 230 V / 47-63 Hz / removable mains lead and 110V** version < 2 VA Safety as per IEC61010-1 (2001) 1000V-CATIII – EMC as per EN61326-1 Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C Dimensions (L x D x H): 295 x 295 x 95 mm – Weight: 1.85 kg 3 years *60,000 counts State at Delivery & References MX 5006 multimeter delivered with EU mains power cable, 1.5 m red straight/straight cable, 1.5 m black straight/straight cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe, operating manual on CD and start-up guide on paper > MX5006 MX 5060 multimeter delivered with EU mains power cable, 1.5 m red straight/straight cable, 1.5 m black straight/straight cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe, operating manual on CD, start-up guide on paper and remote programming manual > MX5060 Accessories SX-DMM software for bench-top multimeters > SX-DMM2 Set of 2 x BNC/banana leads with rear connection > AG1066-Z Calibration kit > P01196770 K thermocouple with adapter > P01102107Z Replacement parts 1.5 m mains power cable 1000 V 11 A fuse (x5) 1.80 m USB A/B cable ** MX5006-110 and MX5060-110 versions available on request UNITED KINGDOM Chauvin Arnoux Ltd Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury, West Yorkshire - WF12 7TH Tel: +44 1924 460 494 Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com MIDDLE EAST Chauvin Arnoux Middle East P.O. BOX 60-154 1241 2020 JAL EL DIB - LEBANON Tel: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com AD.COM - Code : 906211382 - Ed.1 - 09/2013 - Characteristics subject to modifications according to technological developments. DC, AC and AC+DC voltages Range Resolution* DC accuracy AC and AC+DC bandwidth AC ans AC+DC basic accuracy VLowZ AC basic accuracy (520 kΩ) Bench-top Multimeters 6,000 and 60,000 counts Simple and effective for your laboratories… l Error-free current measurement up to 10 A thanks to the single A terminal l TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth l Measurement stability with the VLowZ calibre which eliminates spurious voltages l Measurement stability on variable speed drives with the 300 Hz PWM filter l Recording and monitoring of the signed Min, Max and Peak values l Compliance with

Open the catalog to page 1
MX 5006, MX 5060 - 2

Versatile, communicating multimeters Designed for operation in total safety, the MX 5006 & MX 5060 TRMS multimeters can be used for a wide variety of applications in the electrical engineering and electronics sectors. With their measurement ranges and the multiple possible combinations, they are particularly versatile. 600 V CAT IV & 1,000 V CAT III electrical engineering applications The table below shows all the functions which you can apply (or not) to the measurements in order to broaden their scope. Due to their high level of electrical safety, the MX 5006 and MX 5060 can be used for...

Open the catalog to page 2
MX 5006, MX 5060 - 3

TECHNICAL SPECIFICATIONS DC, AC and AC+DC current Range Resolution* DC accuracy AC and AC+DC bandwidth AC and AC+DC accuracy Frequency Frequency range Resolution* Resistance and continuity Range Resolution* Basic accuracy Protection Audible continuity detection Diode test Voltage measurement Capacitances Range Resolution K thermocouple temperature Operating range Accuracy / Resolution Other functions Min/Max/Peak ± ΔREL PWM filter Central Zero USB communication Measurement rate and bargraph General specifications Display type 1,000 V electronic protection 600 Ω SIGNAL <30 Ω +/-5 Ω < 5V 3 V,...

Open the catalog to page 3

All CHAUVIN ARNOUX catalogs and technical brochures

  1. PANEL METERS

    4 Pages

  2. T82N

    12 Pages

  3. ELINK 61850

    2 Pages

  4. MEMO RANGE

    4 Pages

  5. ULYS

    4 Pages

  6. TC CLIP

    2 Pages

  7. TCX 01

    2 Pages

  8. RDTE

    4 Pages

  9. F-OK B

    2 Pages

  10. RGBE

    2 Pages

  11. RE 3000

    2 Pages

  12. C.A 1875

    2 Pages

  13. BDH R100

    3 Pages

  14. PROBIX

    4 Pages

  15. OX9302-BUS

    4 Pages

  16. C.A 876

    2 Pages

  17. C.A 832

    1 Pages

  18. C.A 6255

    4 Pages

  19. CA 6165

    4 Pages

  20. DL 53

    2 Pages

  21. CBF01

    2 Pages

  22. MX 604

    2 Pages

  23. MX 409

    4 Pages

  24. CA 6528

    4 Pages

  25. MX 535

    4 Pages

  26. CA 6011

    4 Pages

  27. C.A 6418

    2 Pages

  28. PAC Series

    4 Pages

  29. ASYC IV

    8 Pages

  30. SCOPIX IV

    8 Pages

  31. MEMO P200

    2 Pages

  32. GRIDWATCH

    6 Pages

  33. ULYS MCM

    4 Pages

  34. C.A 7028

    3 Pages

  35. HypeReal

    4 Pages

  36. THYRITOP 600

    4 Pages

  37. THYRITOP 500

    4 Pages

  38. THYRITOP 500

    3 Pages

  39. THYRITOP 200

    2 Pages

  40. THYRITOP 100

    2 Pages

  41. CA 8345

    12 Pages

  42. CA 8220

    4 Pages

  43. C.A 847

    1 Pages

  44. C.A 895

    2 Pages

  45. C.A 1950

    4 Pages

  46. CA 1954

    4 Pages

  47. CA 1310

    2 Pages

  48. CA 1900

    2 Pages

  49. C.A 5011

    2 Pages

  50. F65

    4 Pages

  51. CA 6292

    4 Pages

  52. C.A 6240

    2 Pages

  53. C.A 6630

    2 Pages

  54. C.A 6121

    4 Pages

  55. CA 1550

    2 Pages

  56. C.A 1510

    4 Pages

  57. CA 1227

    2 Pages

  58. C.A 1110

    2 Pages

  59. C.A 1246

    2 Pages

  60. C.A40

    2 Pages

  61. CA 10141

    4 Pages

  62. C.A 10101

    4 Pages

  63. C.A 10001

    2 Pages

  64. CA 10002

    2 Pages

  65. VASD 40

    2 Pages

  66. C.A 745N

    2 Pages

  67. CA 6651

    2 Pages

  68. MX 531

    2 Pages

  69. C.A 6470N

    4 Pages

  70. E Series

    8 Pages

  71. E25 & E27

    2 Pages

  72. B100 series

    4 Pages

  73. MH SERIES

    5 Pages

  74. DN SERIES

    15 Pages

  75. K SERIES

    4 Pages

  76. C100 series

    18 Pages

  77. YN SERIES

    9 Pages

  78. MN SERIES

    16 Pages

  79. MINI series

    12 Pages

  80. Handscope

    4 Pages

Archived catalogs