Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
1052 & MTX 1054 digital recorder-analyser oscilloscopes 112 & MTX 162, Didascope and digital oscilloscope 1032 differential probes 1050 spectrum analyser • MTX 1052 & MTX 1054 oscilloscopes with FFT analysis, harmonic analysis and recording function - 2 or 4 channels, 150 MHz or 200 MHz, vertical sensitivity 250 μV – 100 V/div - Advanced trigger modes and SPO analysis - Communication with PC directly by USB or via Ethernet network (wired or WiFi depending on model) • MTX 162 compact, low-cost oscilloscope and MTX 112 differential oscilloscope (10 MHz, USB) - 2 channels, 10 or 60 MHz, normal or remanent display (like an analogue oscilloscope) - Communication with PC directly by USB or via Ethernet network (wired or WiFi depending on model) • MTX 1032 differential probes for measuring signals not referenced to - 2 isolated channels, input voltage 600 V and 600 Vrms in common mode - Attenuation 1/10 and 1/100 - Bandwidth 50 MHz / BNC (MTX 1032-C) or 30 MHz / banana (MTX 1032-B) • MTX 1050 spectrum analyser (400 kHz to 1 GHz) - Ideal for EMC prequalification tests with built-in FM demodulator - Direct communication with PC via US
Open the catalog to page 1SCOPEin@BOX Screenless Oscilloscopes and DIDASCOPEin@BOX PC ergonomics and environment The MTX-1052-PC, MTX 1054-PC and MTX 162 are genuine "oscilloscopes in a box". Compact, lightweight and stackable, these measurement instruments can be connected directly to a PC via a USB or Ethernet interface with dedicated PC software. New WiFi versions now allow wireless Ethernet communication. . COPEin@BOX, control panel S General commands . SCOPEin@BOX, display of "X(t)" traces in SPO mode Users benefit from all the PC’s advantages in terms of storage capacity (the capacity of the PC) and display...
Open the catalog to page 2. SCOPEin@BOX, simultaneous "X(t)", "XY" and "FFT" display Functions Each of these models offers functions which are rare on this type of instrument: real-time FFT analyser (lin/log), recorder or dedicated ROLL mode to simplify adjustments (MTX 162 and MTX 112), bandwidth limiters, simultaneous automatic measurements with markers and cursors, etc. For simpler use, an automatic Autorange mode is available on all the oscilloscopes with remote display. The Vertical Autorange function constantly adjusts the sensitivity on the signal amplitude. The MTX 112 is a 600 V CAT II differential...
Open the catalog to page 3Logic analysis probe specially designed for BUS decoding! When the MTX 1052 and MTX 1054 oscilloscopes are hooked up to the LX1600-PC 16-channel logic analyser, they can decode a wide range of buses: UART, I2C, SPI, CAN, LIN, Modbus, etc. Oscilloscope acquisition can be synchronized on the basis of the trigger conditions for the logic analyser. MTX 1032 Differential Probes The MTX 1032-B and MTX 1032-C differential probes are essential tools for viewing signals not referenced to earth on analogue or digital oscilloscopes. They can be used separately or hooked up to MTX oscilloscopes or to...
Open the catalog to page 4The MTX 1050 spectrum analyser is a compact, low-cost, "screenless" instrument. Lightweight, portable and suitable for general-purpose applications, the MTX 1050 is ideal for small or medium-sized businesses and technical education (engineering schools, technical colleges, etc.). Economical and simple to operate, the MTX 1050-PC includes a Windows environment that makes it easy to take screenshots for reports or data transfer into Excel. The functions and ergonomics of the SCOPEin@BOX oscilloscopes make them perfect for use with the MTX 1050 spectrum analyser. In addition, the instruments...
Open the catalog to page 5The HX0082 kit comprises 2 near-field probes (30 MHz – 3 GHz). The proximity probe is for measuring radiofrequency magnetic fields. It can be used up to 10 cm from the target. The contact probe offers accurate measurements on chip floorplans or printed-circuit traces. The HX0083 kit contains a 20 dB preamplifier for HX0082 nearfield probes. This is designed to provide greater accuracy by amplifying signals close to the noise level. Current consumption The spectrum analyser with its near-field probes: a dedicated EMC prequalification testing kit These tests may take place throughout the...
Open the catalog to page 6Use of near-field probes The various fields measured by this type of probe help to locate the sources of high-frequency electromagnetic fields causing disturbances. Active H-field probes work by observing the disturbance currents. Because they are not sensitive to outside disturbances, they can measure the intensity of the field directly associated with the currents flowing in the conductors. It is not necessary to disconnect the existing wiring to use them. They are used with a spectrum analyser equipped with Peak & Q-Peak detection modes. These modes are ideal for measurements in the...
Open the catalog to page 7MTX Virtual Series SCOPEin@BOX MTX 1052B MAN-MACHINE INTERFACE Display Colour PC screen display / 8 x 10 div / Multi-windowing with up to 4 curves on screen / "Windows-like" interface & online help OSCILLOSCOPE MODE Vertical deflection Bandwidth 2 channels, class 1, common chassis earths 2.5 mV – 100 V/div, up to 250 μV/div with vertical expansion 35 calibres from 1 ns to 200 s/div 32 calibres from 5 ns to 100 s/div 29 calibres from 100 ms to 200 s/div 2 channels, class 1, common chassis earths Vertical sensitivity 4 channels, class 1, common chassis earths Horizontal deflection Sweep speed...
Open the catalog to page 8All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages