Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
Current clamps for AC current Pinces ampèremetriques pour courant AC MINI series Serie MN MINI SERIES Small, compact and particularly resistant, this range of miniature clamps is designed for measurements from a few milli-amperes to 150 A AC. Their shape makes them very practical in confined spaces, such as circuit-breaker boards, control panels or control boxes. They are ideal for use with multimeters. There are two types of MINI clamps. The first type operates like a traditional current transformer and provides a current output (mA) which can be used with multimeters, loggers or instruments with current calibres. The second provides a voltage output proportional to the current measured. This voltage output enables instruments with AC voltage calibres to display or store current values. Non-contractual document There is also a model with a DC voltage output. The MINI clamps give True RMS results when used with a True RMS instrument. MINI 100 SERIES Incorporating all the essentials which made the Miniclamps and the MINI 10 Series so successful, the MINI 100 Series completes the range with a clamping diameter of 16 mm. The models in the MINI 100 Series are equipped with a so-called “direct reading” input/output ratio and can measure currents up to 350 A.
Open the catalog to page 1Current clamps for AC current Pinces ampèremetriques pour courant AC MINI series Serie MN Non-contractual document
Open the catalog to page 2Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 01 150 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 01 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. If there is a current in the conductor clamped, the MINI 01 clamp is protected against overvoltages during disconnection from the measurement instrument. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated...
Open the catalog to page 3Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 02 100 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION The MINI 02 current clamp, whose jaws are equipped with a highperformance magnetic material and a double coil, offers excellent linearity and improved performance. Small and compact, it is ideal for measuring AC currents in low-power tertiary or industrial applications. If a current is present in the conductor being clamped, the MINI 02 clamp is protected against voltage surges when it is disconnected from the measurement instrument. MAIN...
Open the catalog to page 4Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 02 MINI series Serie MN CURVES AT 50 HZ Typical linearity error for loads of 1, 10, 30 and 100 Ω Typical phase shift for loads of 1, 10, 30 and 100 Ω FREQUENCY RESPONSE AT 10 A Typical linearity error for loads of 1, 10, 30 and 100 Ω Typical phase shift for loads of 1, 10, 30 and 100 Ω (1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75 % RH, sinusoidal signal with frequency of 48 Hz at 10 kHz, distortion factor < 1 % with no DC component, external DC magnetic field < 40 A/m, no external AC magnetic field, no...
Open the catalog to page 5Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 03 Calibre MINI series Serie MN DESCRIPTION Small and compact, the MINI 03 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. When used with an AC voltmeter, it allows you to directly read the current measured on the voltmeter. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male banana connectors Ø...
Open the catalog to page 6Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 05 Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 05 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. With its 2 calibres, it offers excellent resolution for measuring AC currents from 5 mA to 100 A. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male banana...
Open the catalog to page 7Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 09 150 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 09 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. Its DC voltage output helps to overcome the low sensitivity of certain AC measurement instruments. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male...
Open the catalog to page 8Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 102 200 A AC Calibre Sensitivity MINI 100 series Serie MN DESCRIPTION The MINI 102 current clamp, whose jaws are equipped with a highperformance magnetic material and a double coil, offer excellent linearity and improved performance. If a current is present in the clamped conductor, the MINI 102 clamp is protected against voltage surges when it is connected to the measuring instrument. MAIN SPECIFICATIONS (1) Calibre Measurement range Phase shift Output signal 200 A 50 mA .. 200 A (load 1 Ω) 50 mA .. 200 A (load...
Open the catalog to page 9Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 102 MINI 100 series Serie MN CURVES AT 50 Hz Typical linearity error for loads of 1, 10 and 100 Ω Typical phase shift for loads of de 1, 10, 30 and 100 Ω Error Erreur Courant Current Courant Current Error Erreur (%) 10 ohms Phase (°) 10 ohms Error Error Erreur (%) 100 ohms Phase (°) 100 ohms Error FREQUENCY RESPONSE AT 10 A Typical linearity error for loads of 1, 10 and 100 Ω Typical phase shift for loads of 1, 10 and 100 Ω Frequency Frequency response at 10 A: amplitude Frequency response at 10 A: phase Error...
Open the catalog to page 10All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages