Current clamps for AC current Pinces ampèremetriques pour courant AC MINI series Serie MN MINI SERIES Small, compact and particularly resistant, this range of miniature clamps is designed for measurements from a few milli-amperes to 150 A AC. Their shape makes them very practical in confined spaces, such as circuit-breaker boards, control panels or control boxes. They are ideal for use with multimeters. There are two types of MINI clamps. The first type operates like a traditional current transformer and provides a current output (mA) which can be used with multimeters, loggers or instruments with current calibres. The second provides a voltage output proportional to the current measured. This voltage output enables instruments with AC voltage calibres to display or store current values. Non-contractual document There is also a model with a DC voltage output. The MINI clamps give True RMS results when used with a True RMS instrument. MINI 100 SERIES Incorporating all the essentials which made the Miniclamps and the MINI 10 Series so successful, the MINI 100 Series completes the range with a clamping diameter of 16 mm. The models in the MINI 100 Series are equipped with a so-called “direct reading” input/output ratio and can measure currents up to 350 A.

Open the catalog to page 1
MINI series - 2

Current clamps for AC current Pinces ampèremetriques pour courant AC MINI series Serie MN Non-contractual document

Open the catalog to page 2
MINI series - 3

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 01 150 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 01 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. If there is a current in the conductor clamped, the MINI 01 clamp is protected against overvoltages during disconnection from the measurement instrument. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated...

Open the catalog to page 3
MINI series - 4

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 02 100 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION The MINI 02 current clamp, whose jaws are equipped with a highperformance magnetic material and a double coil, offers excellent linearity and improved performance. Small and compact, it is ideal for measuring AC currents in low-power tertiary or industrial applications. If a current is present in the conductor being clamped, the MINI 02 clamp is protected against voltage surges when it is disconnected from the measurement instrument. MAIN...

Open the catalog to page 4
MINI series - 5

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 02 MINI series Serie MN CURVES AT 50 HZ Typical linearity error for loads of 1, 10, 30 and 100 Ω Typical phase shift for loads of 1, 10, 30 and 100 Ω FREQUENCY RESPONSE AT 10 A Typical linearity error for loads of 1, 10, 30 and 100 Ω Typical phase shift for loads of 1, 10, 30 and 100 Ω (1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75 % RH, sinusoidal signal with frequency of 48 Hz at 10 kHz, distortion factor < 1 % with no DC component, external DC magnetic field < 40 A/m, no external AC magnetic field, no...

Open the catalog to page 5
MINI series - 6

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 03 Calibre MINI series Serie MN DESCRIPTION Small and compact, the MINI 03 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. When used with an AC voltmeter, it allows you to directly read the current measured on the voltmeter. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male banana connectors Ø...

Open the catalog to page 6
MINI series - 7

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 05 Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 05 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. With its 2 calibres, it offers excellent resolution for measuring AC currents from 5 mA to 100 A. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male banana...

Open the catalog to page 7
MINI series - 8

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 09 150 A AC Calibre Sensitivity MINI series Serie MN DESCRIPTION Small and compact, the MINI 09 current clamp is the ideal complement for any multimeter to measure AC currents in low-power tertiary or industrial applications. Its DC voltage output helps to overcome the low sensitivity of certain AC measurement instruments. MAIN SPECIFICATIONS (1) Calibre Measurement range Accuracy of primary current in % Phase shift Output signal Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male...

Open the catalog to page 8
MINI series - 9

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 102 200 A AC Calibre Sensitivity MINI 100 series Serie MN DESCRIPTION The MINI 102 current clamp, whose jaws are equipped with a highperformance magnetic material and a double coil, offer excellent linearity and improved performance. If a current is present in the clamped conductor, the MINI 102 clamp is protected against voltage surges when it is connected to the measuring instrument. MAIN SPECIFICATIONS (1) Calibre Measurement range Phase shift Output signal 200 A 50 mA .. 200 A (load 1 Ω) 50 mA .. 200 A (load...

Open the catalog to page 9
MINI series - 10

Current clamp for AC current Pinces ampèremetriques pour courant AC Model MINI 102 MINI 100 series Serie MN CURVES AT 50 Hz Typical linearity error for loads of 1, 10 and 100 Ω Typical phase shift for loads of de 1, 10, 30 and 100 Ω Error Erreur Courant Current Courant Current Error Erreur (%) 10 ohms Phase (°) 10 ohms Error Error Erreur (%) 100 ohms Phase (°) 100 ohms Error FREQUENCY RESPONSE AT 10 A Typical linearity error for loads of 1, 10 and 100 Ω Typical phase shift for loads of 1, 10 and 100 Ω Frequency Frequency response at 10 A: amplitude Frequency response at 10 A: phase Error...

Open the catalog to page 10

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4 Pages

  2. TC CLIP

    2 Pages

  3. PROBIX

    4 Pages

  4. OX9302-BUS

    4 Pages

  5. C.A 6255

    4 Pages

  6. CA 6165

    4 Pages

  7. CBF01

    2 Pages

  8. MX 604

    2 Pages

  9. MX 409

    4 Pages

  10. CA 6528

    4 Pages

  11. MX 535

    4 Pages

  12. CA 6011

    4 Pages

  13. C.A 6418

    2 Pages

  14. PAC Series

    4 Pages

  15. ASYC IV

    8 Pages

  16. SCOPIX IV

    8 Pages

  17. MEMO P200

    2 Pages

  18. GRIDWATCH

    6 Pages

  19. ULYS MCM

    4 Pages

  20. C.A 7028

    3 Pages

  21. HypeReal

    4 Pages

  22. THYRITOP 600

    4 Pages

  23. THYRITOP 500

    3 Pages

  24. THYRITOP 200

    2 Pages

  25. THYRITOP 100

    2 Pages

  26. CA 8345

    12 Pages

  27. CA 8220

    4 Pages

  28. C.A 847

    1 Pages

  29. C.A 895

    2 Pages

  30. C.A 1950

    4 Pages

  31. CA 1954

    4 Pages

  32. CA 1310

    2 Pages

  33. CA 1900

    2 Pages

  34. C.A 5011

    2 Pages

  35. F65

    4 Pages

  36. CA 6292

    4 Pages

  37. C.A 6240

    2 Pages

  38. C.A 6630

    2 Pages

  39. C.A 6121

    4 Pages

  40. CA 1550

    2 Pages

  41. C.A 1510

    4 Pages

  42. CA 1227

    2 Pages

  43. C.A 1110

    2 Pages

  44. C.A 1246

    2 Pages

  45. C.A40

    2 Pages

  46. CA 10141

    4 Pages

  47. C.A 10101

    4 Pages

  48. C.A 10001

    2 Pages

  49. CA 10002

    2 Pages

  50. VASD 40

    2 Pages

  51. C.A 745N

    2 Pages

  52. CA 6651

    2 Pages

  53. MX 531

    2 Pages

  54. C.A 6470N

    4 Pages

  55. E Series

    8 Pages

  56. E25 & E27

    2 Pages

  57. B100 series

    4 Pages

  58. MH SERIES

    5 Pages

  59. DN SERIES

    15 Pages

  60. K SERIES

    4 Pages

  61. C100 series

    18 Pages

  62. YN SERIES

    9 Pages

  63. MN SERIES

    16 Pages

Archived catalogs

  1. PANEL METERS

    4 Pages

  2. T82N

    12 Pages

  3. ELINK 61850

    2 Pages

  4. Handscope

    4 Pages