Current clamp for AC/DC pour courant AC Pinces ampèremetriquescurrent MH SERIES The MH60 clamp is designed to measure DC and AC currents up to 1 MHz using dual Hall effect/Transformer technology. It includes an internal NiMh rechargeable battery and can be recharged or powered using a 5 VDC power supply via the female type-B μUSB connector with which it is equipped. Non-contractual document It has an automatic standby system (which can be deactivated), an automatic “DCzero” system for compensation of magnetic and electronic drift, a switchable selective filter (3 kHz, 30 kHz) and a system for compensating the effects of the earth field and other constant DC fields. Its ability to measure AC+DC signals is useful for True RMS measurements.
Open the catalog to page 1Current clamp for AC/DC pour courant AC Pinces ampèremetriquescurrent Non-contractual document
Open the catalog to page 2Current probe for AC/DC pour courant AC Pinces ampèremetriquescurrent Model MH60 (insulated AC/DC current probe) Current DESCRIPTION The MH60 clamp is designed to measure DC and AC currents up to 1 MHz using dual Hall effect/ Transformer technology. ELECTRICAL SPECIFICATIONS • • • Current range: 0.5 .. 100 A DC (140 A peak) Output signal: 10 mV AC+DC / A AC+DC (1 V at 100 A) Accuracy and phase shift (1): Calibre Primary current % Accuracy of output signal Phase shift @ 50 Hz (2) Bandwidth: DC .. 1 MHz (-3 dB) (depending on current value) Rise time and fall time: From 10 % to 90 % Without filter:...
Open the catalog to page 3Current clamp for AC /DC pour courant AC Pinces ampèremetriques current Model MH60 (insulated AC/DC current probe) Insertion impedance 0,00 0,01 0,1 1 10 100 1000 Limitation of measurable current according to the frequency Non-contractual document Phase Phase Phase Phase Phase Courant (A) RMS eff. Courantcurrent (A) Courant eff. (A) eff. (A) Courant eff.eff. (A) Courant (A) mOhm mOhm mOhm mOhm mOhm Fréquence (kHz) Fréquence (kHz) 10 100 Fréquence (kHz)
Open the catalog to page 4Current clamp for AC/DC pour courant AC Pinces ampèremetriquescurrent Model MH60 (insulated AC/DC current probe) Input signal: Input signal: Clamp output signal Clamp output signal 1 A peak Input signal: X: 0.1 ms/div Input signal: Clamp output signal X: 0.1 ms/div Clamp output signal Input signal: Input signal: Clamp output signal Clamp output signal Input signal: X: 20 µs/div Y: 0.25 A V/div Clamp output signal X: 20 µs/div Y: 0.25 A/div Non-contractual document
Open the catalog to page 52 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
4 Pages
6 Pages
3 Pages
2 Pages
6 Pages
4 Pages
8 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
12 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
4 Pages
4 Pages
36 Pages
4 Pages
8 Pages
8 Pages
2 Pages
4 Pages
17 Pages
15 Pages
4 Pages
18 Pages
9 Pages
16 Pages
12 Pages
13 Pages
16 Pages
4 Pages
4 Pages
12 Pages
336 Pages
154 Pages
4 Pages
2 Pages
4 Pages
12 Pages
4 Pages
8 Pages
2 Pages
4 Pages
64 Pages