AC/DC CURRENT CLAMPS E Series The E Series is designed to measure alternating and direct currents by means of Hall-effect technology. The currents measured extend from a few milliamperes to more than 100 A. The E25 model provides higher sensitivity for low current measurements. This clamp can be hooked up to multimeters, loggers, data processors, etc. The E27 can be connected directly to an oscilloscope. The long, narrow shape of these clamps makes them ideal for measurements in cable strands or confined spaces such as switchboard wiring, motor control units and the electrical circuits in automotive vehicles. Their low phase shift ensures excellent power measurement performance. These clamps are equipped with a voltage output (mV). Their ability to measure AC+DC signals is particularly useful for True RMS measurements.
Open the catalog to page 1AC/DC CURRENT CLAMPS
Open the catalog to page 2AC/DC CURRENT CLAMP E25 model Current Output Description The E25 clamp is designed to measure alternating and direct currents by means of Hall-effect technology. Its long, narrow shape makes it ideal for measurements in confined spaces where access is difficult. Via a cable terminated by 2 x Ø4 mm isolated male banana plugs, this clamp provides an AC+DC mV signal which is an image of the current measured in terms of waveform and amplitude. The E25 clamp is equipped with an automatic DC Zero system and a deactivatable Auto Power Off (APO) function. It can be powered by battery or by a standard...
Open the catalog to page 3AC/DC CURRENT CLAMP E25 model Typical error of 10 mV/A calibre on 60 Hz alternating current Typical error of 10 mV/A calibre on direct current 80 A calibre Frequency response Typical frequency response at 0.5 A E25 clamp with 1 V/A calibre Typical frequency response at 1 A E25 clamp with 10 mV/A calibre Frequency phase shift Frequency-dependent phase shift at 1 A E25 clamp with 10 mV/A calibre Phase shift Phase shift Frequency-dependent phase shift at 0.5 A E25 clamp with 1 V/A calibre
Open the catalog to page 4AC/DC CURRENT CLAMP E25 model 80 A calibre Pulse response Limitation of measurable current according to the frequency Maximum measurable current (1) Conditions of reference: 23°C ± 5°K, 20 to 75% RH, power supply voltage 6.5 V DC to 9.0 V DC, sinusoidal signal with a frequency from DC to 1 kHz, external magnetic field < 40 A/m, no DC component, no current flowing in external conductor, conductor measured centred, load impedance ≥ 1 MΩ / ≤ 100 pF. (2) Typical value(s) (3) With alkaline battery, no external power supply present E25 model AC/DC current sensor with battery and user’s manual
Open the catalog to page 5AC/DC CURRENT CLAMP E27 model (isolated AC/DC current sensor) Description The E27 clamp is designed to measure alternating and direct currents by means of Hall-effect technology. Its long, narrow shape makes it ideal for measurements in cable strands or confined spaces such as switchboard wiring, motor control units or power supplies or the electrical circuits of automotive vehicles. Via a coaxial cable terminated by an isolated BNC plug, this clamp outputs a signal in mV which is an image of the current measured in terms of waveform and amplitude. The E27 clamp is equipped with an automatic...
Open the catalog to page 6AC/DC CURRENT CLAMP E27 model (isolated AC/DC current sensor) Typical error of 10 mV/A calibre on 60 Hz alternating current Typical error of 10 mV/A calibre on direct current Current on primary (A) Current on primary (A) 100 A calibre Frequency response Typical frequency response at 1 A E27 clamp with 10 mV/A calibre Typical frequency response at 0.5 A E27 clamp with 100 mV/A calibre Frequency phase shift Frequency-dependent phase shift at 1 A E27 clamp with 10 mV/A calibre Phase shift Phase shift Frequency-dependent phase shift at 1 A E27 clamp with 100 mV/A calibre
Open the catalog to page 7AC/DC CURRENT CLAMP E27 model (isolated AC/DC current sensor) 100 A calibre Pulse response Limitation of measurable current according to the frequency Maximum measurable current (1) Conditions of reference: 23°C ± 5°K, 20 to 75% RH, power supply voltage 6.5 V DC to 9.0 V DC, sinusoidal signal with a frequency from DC to 1 kHz, external magnetic field < 40 A/m, no DC component, no current flowing in external conductor, conductor measured centred, load impedance ≥ 1 MΩ / ≤ 100 pF. (2) With alkaline battery, no external power supply present E27 model AC/DC current clamp for oscilloscope with battery...
Open the catalog to page 82 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
4 Pages
6 Pages
3 Pages
2 Pages
6 Pages
4 Pages
8 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
12 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
4 Pages
4 Pages
36 Pages
4 Pages
8 Pages
2 Pages
4 Pages
17 Pages
5 Pages
15 Pages
4 Pages
18 Pages
9 Pages
16 Pages
12 Pages
13 Pages
16 Pages
4 Pages
4 Pages
12 Pages
336 Pages
154 Pages
4 Pages
2 Pages
4 Pages
12 Pages
4 Pages
8 Pages
2 Pages
4 Pages
64 Pages