CHAUVIN® ARNOIX CHAUVIN ARNOUX CROUP
Open the catalog to page 1About the CHAUVIN ARNOUX GROUP Founded in 1893 by Raphaël Chauvin and René Arnoux, CHAUVIN ARNOUX is an expert in the measurement of electrical and physical quantities in the industrial and tertiary sectors. Total control of product design and manufacturing in-house enables the Group to innovate constantly and to propose a very broad product and service offering meeting all its customers’ needs. The Group’s quality policy enables it to deliver products which comply with the specifications, as well as the international and national standards, in the metrological, environmental and user-safety...
Open the catalog to page 2CLamps Catalogue Clamps and flexible probes " accessories " Non-contractual document
Open the catalog to page 3Current clamps Pinces ampèremétriques pour courant AC Current measurement Série MN A modern method for measuring electrical currents Several Chauvin Arnoux® clamps are patented for their unique circuitry and design. Circuit magnétique Iron core Conductor input This same principle is applied to a current clamp (figure 2). The articulated magnetic core holds the coil B2 and clamps onto a conductor where the current I1 is flowing. B1 is simply the conductor where the user is measuring the current with the number of turns N1 equal to one. The current sensor clamped around the conductor provides...
Open the catalog to page 4Current clamps Pinces ampèremétriques pour courant AC Current measurement Série MN A modern method for measuring electrical currents µ0.n di x S. 2π.r dt µ0 = vacuum permeability S = surface area of a turn n = number of turns r = core radius • Theory of Operation (Hall effect) Unlike on traditional AC transformers, AC/DC current measurement is often achieved by measuring the strength of a magnetic field created by a current-carrying conductor in a semiconductor chip using the Hall-effect principle. When a thin semiconductor (figure 6) is placed at right angles to a magnetic field (B), and a...
Open the catalog to page 5Current measurement Current clamps A modern method for measuring electrical currents AC OR DC CURRENT MEASUREMENT • Connect the clamp to the instrument • Select the function and range • Clamp the clamp around a single conductor • Read the conductor’s current value Examples (figure 8): AC: clamp model: Y2N Ratio: 1000:1 Output: 1 mA AC/A AC DMM: set to 200 mA AC range DMM reading: 125 mA AC Current in conductor: 125 mA x 1000 = 125 A AC DC: clamp model: PAC 21 1 mV DC/A DC (Hall sensor) DMM: set to 200 mV DC range DMM reading: 160 mV DC Current in conductor: 160 A DC AC: clamp model: PAC...
Open the catalog to page 6Current clamps Pinces ampèremétriques pour courant AC Current measurement Série MN A modern method for measuring electrical currents SELECTING A CURRENT PROBE Answering the following questions will help you to select the appropriate clamp for your applications: Other factors you may want to consider: • What is the working voltage of the conductor to be measured ? 1. Determine if you are measuring AC or DC (DC current clamps are categorized as AC/DC because they measure both). • Chauvin Arnoux clamps must not be used above 600 volts (see specifications). 2. What is the the maximum current you...
Open the catalog to page 7Selection guide — (1) The upper value corresponds to 120 % of the maximum rated value (2) Remise en forme du signal alternate par diodes (3) Lead + electronic unit with 0 4 mm safety connectors, centre distance 19 mm, for K and AmpFlex®
Open the catalog to page 8Selection guide — (1) The upper value corresponds to 120 % of the maximum rated value (3) Lead + electronic unit with 0 4 mm safety connectors, centre distance 19 mm, for K and AmpFlex®
Open the catalog to page 9Selection guide — (1) The upper value corresponds to 120 % of the maximum rated value (3) Lead + electronic unit with 0 4 mm safety connectors, centre distance 19 mm, for K and AmpFlex® i.2 (3/3) CHAUVIN® ARNOUX CHAUVIN AR
Open the catalog to page 10Selection guide — (1) The upper value corresponds to 120 % of the maximum rated value (3) Lead + electronic unit with 0 4 mm safety connectors, centre distance 19 mm, for K and AmpFlex®
Open the catalog to page 11Selection guide — Leakage current measurement Measurement of process current (1) The upper value corresponds to 120 % of the maximum rated value (3) Lead + electronic unit with 0 4 mm safety connectors, centre distance 19 mm, for K and AmpFlex®
Open the catalog to page 12Current clamps for AC current Pinces ampèremetriques pour courant AC MINI series Serie MN MINI SERIES Small, compact and particularly resistant, this range of miniature clamps is designed for measurements from a few milli-amperes to 150 A AC. Their shape makes them very practical in confined spaces, such as circuit-breaker boards, control panels or control boxes. They are ideal for use with multimeters. There are two types of MINI clamps. The first type operates like a traditional current transformer and provides a current output (mA) which can be used with multimeters, loggers or instruments...
Open the catalog to page 14MINI series — CHAUVIN® ARNOUX CHAUVIN ARNOUX GROUP
Open the catalog to page 15MINI series — Current clamp for AC currentModel MINI 01 Calibre DESCRIPTION Small and compact, the MINI 01 current clamp Is the Ideal complement for any multimeter to measure AC currents In low-power tertiary or industrial applications. If there Is a current in the conductor clamped, the MINI 01 clamp Is protected against overvoltages during disconnection from the measurement instrument. CHAUVIN® ARNOUX CHAUVIN AR
Open the catalog to page 16MINI series Current clamp for AC current Model MINI 02 Calibre DESCRIPTION The MINI 02 current clamp, whose jaws are equipped with a high-performance magnetic material and a double coil, offers excellent linearity and improved performance. Small and compact, it is ideal for measuring AC currents in low-power tertiary or industrial applications. If a current is present in the conductor being clamped, the MINI 02 clamp is protected against voltage surges when it is disconnected from the measurement instrument. • Output: Double-insulated cable 1.5 m long, terminated by 2 insulated elbowed male...
Open the catalog to page 17All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages