Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
About the CHAUVIN ARNOUX GROUP Founded in 1893 in Paris, France, CHAUVIN ARNOUX, has succeeded over the centuries in constantly developing its expertise in the design, manufacture and commercialization of measuring instruments for professionals. From portable instrumentation to fixed electrical equipment and energy performance solutions, from control of the whole thermal process chain to industrial metrology, the CHAUVIN ARNOUX Group’s offering covers every customer requirement, whatever the sector (contractors, industry, administration, etc.). CHAUVIN ARNOUX is a in the “measurement market...
Open the catalog to page 2Temperature and process signal calibrators Thermal cameras IR and contact thermometers Temperature sensors Sound meters and manometers Tachometers and field meters
Open the catalog to page 3Temperature & process signal calibrators CA 1621 Input/output range Temperature calibrator for thermocouple probes capable of measuring and simulating up to 8 types of thermocouple as well as a voltage in mV. Reference junction error Delivered with a soft case, 2 thermocouple adapters, 6 x AAA 1.5 V batteries and a user’s manual in 5 languages Temperature calibrator for resistive probes capable of measuring and simulating up to 7 types of resistive probes as well as a resistance. STATE AT DELIVERY Supplied with a soft case, a pair of test cables, a pair of crocodile clips, 6 x AAA 1.5 V...
Open the catalog to page 4CA 1950 Detector Sensitivity (N.E.T.D) Refresh rate Temperature range Accuracy Field of view IFOV (spatial resolution) Focus Real image Fixed Yes Automatic Min and Max detection on adjustable area 1 manual cursor + automatic detection + Min Max on adjustable area + temperature profile + isotherm Emissivity, environmental temperature, distance, relative humidity Yes, via Bluetooth (earpiece supplied) Measurement tools Parameter settings Voice comments Connectivity Data storage Type Battery life Ingress protection Fall resistance Weight / dimensions F407, F607, MTX 3292 and MTX 3293 clamps,...
Open the catalog to page 5Thermal camera For body temperature measurement Detector Type Sensitivity (N.E.T.D.) Refresh rate Temperature range Accuracy Quick measurement No contact ± 0,5 °C @ 37 °C Instantaneous temperature detection Audible and visual alerts Optics IFOV (spatial resolution) Focusing Minimum focal distance Real image Measurement tools For any abnormally high temperature Data storage Adjustment Battery life Interfaces Mass / dimensions Practical mounting Field of view: 38° x 28° 4.1 mrad Fixed 30 cm Yes (320 x 240 pixels) 1 manual cursor + 1 for automatic hotspot detection + Isotherm Adaptive alarm...
Open the catalog to page 6IR thermometers & contact thermometers CA 1860 Ref.: P01651815 CA 1871 Emissivity Mesurement range Adjustable from 0.1 to 1.0 Fixed : 0.95 -35 °C to +450 °C -35 °C to +650 °C -30 °C to + 550 °C (-31 °F to +842 °F) (-31 °F to +1202 °F) Output 1 mV/°C 0.1 °C (0.1 °F) ± 1.8 °C or ± 1.8 % of reading ± 2 % (take the higher value) Dimensions / weight Instantaneous mode, MAX, MIN, AVG, differential (DIF), continuous measurement Min, Max, Avg, Hold, Alarms, Diff by blocking measurement trigger, alarms Laser sight * Depending on temperature range. See user’s manual for further details. Products...
Open the catalog to page 7Sensor No. of inputs Range Resolution Accuracy Functions Recording Alarms Battery life Ingress protection Mounting Connections Dimensions/weight J, K, T, N, E, R or S thermocouple Pt100, Pt1000 1 2 1 -250 °C to 1767 °C -100 °C to 400 °C θ < 1,000 °C: 0.1 °C and 0.1 °C θ ≥ 1,000 °C: 1 °C ± (0.1 % R + 0.6 °C) ± (0.4 % R +0.3 °C) ± (0.4 % R +0.3 °C) Min., Max., HOLD, Alarms Manual start and stop on the product Programmed recording Visual alert if a threshold is overrun configurable via Data Logger Transfer Possibility of triggering recording on alarm threshold 1,000 hrs (portable mode) / 3...
Open the catalog to page 8Temperature sensors K thermocouple sensors Models Measurement range Tolerance class Plunger diameter Plunger length Needle sensor for penetration with stainless-steel sheath Bendable general-purpose sensor with stainless-steel sheath Semi-rigid general-purpose sensor with stainless-steel sheath Surface sensor Sheathed with stainless-steel sensing element and Teflon base Surface sensor with spring Flexible sensor not suitable for liquids 1 second in contact 3 s ambient Air sensor for ambient measurement Pipe sensor Needle sensor for penetration with handle Stainless -steel sheath...
Open the catalog to page 9Relative Humidity range Relative Humidity accuracy Temperature range Temperature accuracy Dew point range and accuracy Functions Recording Alarms Battery life Ingress protection Mounting Dimensions / weight 3.0 to 98.0 % RH 10 to 90 %RH: ± (2 % RH ± 1 ct) outside that range: ± (4 % RH ± 1 ct) - 10.0 to +60.0 °C 10 to 40 °C: ± (0.5 °C ± 1 ct) outside that range: ± (0.032 x (T-25) ± 1 ct) / T= temperature in °C Dew point: - 20.0 to +60.0 °Ctd Accuracy: 1.5 °C Min., Max., HOLD, Alarms Manual start and stop on the product Programmed recording Visual alert on threshold overrun configurable via...
Open the catalog to page 10CA 1110 Measurement range Accuracy in standard mode Incandescent lamp LED Fluorescent lamps Accuracy in compensation mode LED mode Fluo mode Functions Recording MAP mode Data storage Power supply Battery life Dimensions Weight Ingress protection Operating temperature / humidity Standards 0.1 to 200,000 lx - 0.01 to 18,580 fc ± 3 % of reading ± 6 % of reading (3,000 K and 6,000 K) ± 9 % of reading ± 4 % of reading (at 4,000 K) ± 4 % of reading (type F11, 4,000 K) Min., Max., HOLD, Average Manual start and stop on the product Programmed recording The MAP function can be used to map the...
Open the catalog to page 11Measurement range Accuracy Resolution Recording interval Data storage Buzzer and units Backlighting / Hold /Min Max Dimensions / weight Power supply CO2 Temperature Humidity 0 to 5,000 ppm -10 °C to +60 °C 5 to 95 % RH ± 50 ppm ±3 % R ±0.5 °C ± 2 % RH 1 ppm 0.1 ° C 0.1 % RH Customizable from 1 minute to 2 hours More than 1 million points Yes / °C or °F Yes 125 x 65.5 x 32 mm / 190 g with batteries Batteries: 2 x 1.5 V LR6 or rechargeable battery Possibility of mains connection with mains / micro USB adapter supplied as standard 2 possible communication modes: Bluetooth wireless link and USB...
Open the catalog to page 12All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages