Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
Simple measurement at the best price Universal Test & Measurement Electrical Safety Testers Other Measurements Laboratory Instruments
Open the catalog to page 1Contents Universal Test & Measurement ……………… page 3 Electrical Safety Testers ……………………… page 8 Other Measurements …………………………… page
Open the catalog to page 2Universal Test & Measurement Pocket multimeters 100 A to 600 A AUTO-RANGING CM 603 Clamping diameter Measurement type Ranges Basic accuracy Best resolution Ranges 26 mm 4,000 counts with backlighting Best resolution Best resolution Continuity (with buzzer) Other features Dimensions / weight Accessories supplied 1 set of red/black test-probe leads, 3 x 1.5 V AAA / LR03 batteries, 1 K thermocouple and 1 carrying bag Basic accuracy Basic accuracy Best resolution Ranges Backlighting, Torch function, Data HOLD, Deactivatable automatic power-off Basic accuracy Best resolution Diode test Basic...
Open the catalog to page 3Universal Test & Measurement Digital multimeters Clamping diameter Display Measurement type Basic accuracy Best resolution Basic accuracy Best resolution Ranges Basic accuracy Best resolution Automatic zero adjustment Yes Analogue output: 10 mV/A AC or DC, 4.5 % + 0.5 mV, 20 kHz to ± 3 dB, Z = 3 kΩ HOLD / PEAK (peak value) Other features Dimensions / weight Accessories supplied 1 carrying bag, 1 set of red/black test-probe leads and 2 x 1.5 V LR3/AAA batteries Pocket clamp-on multimeters DMM 16 6,600 counts with backlighting AVG Display Measurement type Ranges Basic accuracy Best resolution...
Open the catalog to page 4Measurement type TRMS AC/DC Basic accuracy Best resolution Basic accuracy Best resolution Basic accuracy Best resolution Basic accuracy Best resolution Continuity (with buzzer) Diode test Ranges Ranges Resistance Basic accuracy Best resolution Capacitance Temperature Duty cycle Range selection Other features Backlighting, Data HOLD, Torch function, NCV: no-contact detection of electric fields (voltage), Deactivatable automatic power-off Backlighting, Data HOLD, Deactivatable automatic power-off, Relative mode Dimensions / Weight Accessories supplied 1 set of red/black test-probe leads, 2 x...
Open the catalog to page 5Universal Test & Measurement Digital multimeters DMM 210 6,000 counts Backlit with bargraph 40,000 counts Backlit with bargraph TRMS AC/DC 50 Hz to 1 kHz 400 µA / 4000 µA / 40 mA / 400 mA / 10 A (20 A max.) 1.0 % + 3 cts 0.01 µA – 25 % to 125 % 400 µA / 4000 µA / 40 mA / 400 mA / 10 A (20 A max.) 1.5 % + 3 cts 0.1 µA 400 mV / 4 V / 40 V / 400 V / 1,000 V 0.06 % + 2 cts 0.01 mV 400 mV / 4 V / 40 V / 400 V / 1,000 V 1.0 % + 3 cts 0.1 mV 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ Basic accuracy Best resolution Measurement type Bandwidth Ranges Basic accuracy Best resolution Basic accuracy...
Open the catalog to page 6Voltage tester Wallplug Tester 2P+E mains socket and RCD tester • Voltage testing: 12 V to 690 V~ (7 diodes) • Impedance: 400 kΩ • Operating frequency: DC and 50/60 Hz • Polarity test with «+» and «-» diodes • Protection up to 1,000 V • IEC 61010 600 V CAT III VT 11 For renovation work and quick checking of 2P+E socket connections Tests performed: • PE (Earth (1)) not connected • Line (L) not connected Dimensions / Weight: • Inversion of Line (L) / Earth (PE) • Inversion of Line (L) / Neutral (N) (1) “Earth” or “Protective conductor” Phase detector with built-in torch • Quick testing of...
Open the catalog to page 7Electrical Safety Testers Digital earth resistance tester Digital insulation tester at 1,000 V 2 P and 3 P measurement methods • Measurement of earth potential up to 200 VAC • 3 measurement ranges: 20 Ω / 200 Ω / 2 000 Ω • Data Hold • Safety: 200 V Cat. III (IEC 61010-1) Insulation measurement at 250 Vdc / 500 Vdc / 1, 000 Vdc up to 2,000 Ω Timer / DATA HOLD / compensation of leads Safety: 300 V Cat. III (IEC 61010-1) • Voltage measurement: 0 to 600 Vac • Continuity measurement (I > 200 mA) with buzzer • Measurement comfort: voltage presence LED / ongoing insulation test LED • Automatic...
Open the catalog to page 8Other Measurements Circuit Breaker Finder Digital tachometer RPM 82 Automatic calibre selection For simple location of fuses and circuit-breakers MAX, MIN, HOLD • Operation with or without contact • Accuracy: 0.05 % + 1 count • Rotation speed and linear rotation speed with contact: 0.5 rpm to 19,999 rpm rotation without contact: 2.5 rpm to 99.999 rpm linear speed: 0.05 m/min to 1,999.9 m/min Operating voltage Operating frequency Power supply Dimensions Weight Safety USB temperature and humidity recorder Supplied with three adapters for: mains socket, B22 socket (bayonet), E27 socket...
Open the catalog to page 9Other Measurements Cable tester for telephone, computer and video wiring CT 51 Removable transmitter module: only one person needed for testing • For cables: RJ-45 / RJ-11 / USB / 1394 / BNC • Testing for continuity, breaks and short-circuits • Measurements on cables up to 180 m long To order P06237901 Dimensions / Weight: 200 x 100 x 27 mm / 280 g (everything included) Supplied with cable adapters and a 9 V battery Stud (wood/metal) and live cable detector No more blind drilling into wooden or plasterboard walls • Location of live electrical cables • Detection of metal items (pipes, etc.)...
Open the catalog to page 10Laboratory Instruments Power Supplies XA 1525 Single-output DC laboratory power supply Single-output DC laboratory power supply • Separate display of voltage and current settings • Separate display of voltage and current settings • Coarse and fine voltage output adjustment • Coarse and fine voltage output adjustment • Full overload protection • Full overload protection XA 3052 Dual-output DC laboratory power supply Triple-output DC laboratory power supply • Two 0-30.0 VDC / 0-3.0 ADC adjustable outputs and one 5 VDC / 3 ADC fixed output • The 2 independent outputs can be set up in parallel...
Open the catalog to page 11All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages