Group: CHAUVIN ARNOUX GROUP
Catalog excerpts
C.A 6522 – C.A 6524 – C.A 6526 C.A 6532 – C.A 6534 – C.A 6536 Insulation and Continuity Testers ●● Test voltage from 10 V to 1,000 V / 200 GΩ ●● Manual, Lock, Timer and PI / DAR Ratios modes ●● Visual Pass / Fail: red / green ●● 200 mA / 20 mA continuity with active protection without fuses ●● Measurement of V (TRMS & DC), F, Ω, kΩ, C and cable length ●● ΔRel mode & configurable alarms ●● Storage of
Open the catalog to page 1Insulation and Continuity Testers Ergonomics Chauvin Arnoux’s compact, lightweight testers are easy to learn how to use. All the information and measurement results are displayed on the backlit screen. Access to the instrument parameters and information Logarithmic bargraph to display the insulation measurements Secondary display - odification of M the display and programming of the insulation measurement durations - hoice of the current C for continuity measurement - rogramming of the P alarm thresholds Main display To compensate the resistance of the measurement leads ∆Rel to display the...
Open the catalog to page 2Applications > NDUSTRIAL MAINTENANCE I C.A 6522, C.A 6524 and C.A 6526 Periodic insulation tests on installations and equipment help to prevent incidents by setting up preventive maintenance designed to detect ageing and premature deterioration of their insulation characteristics: Thanks to its wide test-voltage range from 10 V to 500 V, this model covers the specific requirements of the electronics industries, for both low-current applications and power stages. Its measurement range is from 2 kΩ to 50 GΩ. With appropriate electrodes, the 10 V and 100 V test voltages can also be used for...
Open the catalog to page 3Insulation and Continuity Testers C.A 6522 Voltage Measurement range / Resolution Accuracy / Input impedance Operating frequency Frequency Measurement range / Resolution / Accuracy Insulation Test voltage Range at maximum test voltage Compliance with IEC 61557-2 standard Measurement range: 10 V 25 V 50 V 100 V 250 V 500 V 1,000 V Variable test voltage 10(1) - 999 kΩ and 1.000 - 3.999 MΩ / 1 kΩ; 4.00 - 39.99 MΩ / 10 kΩ; 40.0 - 399.9 MΩ / 100 kΩ; 400 - 3,999 MΩ / 1 MΩ; 4.00 - 39.99 GΩ / 10 MΩ; 40.0 - 200 GΩ / 100 MΩ ± (3 % + 2 cts)(2) - 0 % + 20 % ± (3 % + 3 cts) 0.01 µA - 39.99 µA / 10 nA;...
Open the catalog to page 4All CHAUVIN ARNOUX catalogs and technical brochures
-
ULYS FLEX Modbus
2 Pages
-
ULYS MD45 & ULYS MD100
4 Pages
-
MEMO RANGE
4 Pages
-
TC CLIP
2 Pages
-
PROBIX
4 Pages
-
OX9302-BUS
4 Pages
-
C.A 6255
4 Pages
-
CA 6165
4 Pages
-
CBF01
2 Pages
-
AX501, AX502, AX503, AX503F
2 Pages
-
MX 5006, MX 5060
3 Pages
-
MX 604
2 Pages
-
MX 409
4 Pages
-
CA 6528
4 Pages
-
VX 0003 , VX 0100
4 Pages
-
MX 535
4 Pages
-
CA 6011
4 Pages
-
C.A 6418
2 Pages
-
CA 6422 & CA 6424
4 Pages
-
PAC Series
4 Pages
-
GX 305 GX 310 GX 320
4 Pages
-
ASYC IV
8 Pages
-
SCOPIX IV
8 Pages
-
CA 922 - CA 942
4 Pages
-
THYRITOP 700 SERIES
6 Pages
-
OX 5022B – OX 5042B
3 Pages
-
MEMO P200
2 Pages
-
GRIDWATCH
6 Pages
-
ULYS MCM
4 Pages
-
MEMO & ULYS MEMO & ULYS
8 Pages
-
C.A 7028
3 Pages
-
Power and Harmonics
2 Pages
-
HypeReal
4 Pages
-
THYRITOP 600
4 Pages
-
THYRITOP 500
3 Pages
-
THYRITOP 200
2 Pages
-
THYRITOP 100
2 Pages
-
CA 8345
12 Pages
-
CA 8220
4 Pages
-
C.A 1725 , C.A 1727
4 Pages
-
C.A 847
1 Pages
-
C.A 895
2 Pages
-
CA 1864 & CA 1866
2 Pages
-
C.A 1950
4 Pages
-
CA 1954
4 Pages
-
CA 1860 & CA 1862
2 Pages
-
CA 1310
2 Pages
-
CA 1900
2 Pages
-
C.A 5277, C.A 5275, C.A 5273
4 Pages
-
C.A 5011
2 Pages
-
C.A 5000 Series
4 Pages
-
F65
4 Pages
-
MA400D ,MA4000D
2 Pages
-
F200 - F400 - F600 Series
8 Pages
-
CA 6292
4 Pages
-
C.A 6240
2 Pages
-
C.A 6630
2 Pages
-
C.A 6121
4 Pages
-
AL 834 , ML 914
2 Pages
-
L452 DATA LOGGER
2 Pages
-
CA 1550
2 Pages
-
SIMPLE LOGGER® II
20 Pages
-
C.A 1510
4 Pages
-
CA 1227
2 Pages
-
C.A 1110
2 Pages
-
C.A 1246
2 Pages
-
PEL 100 SERIES
8 Pages
-
C.A 6541 C.A 6543
4 Pages
-
C.A40
2 Pages
-
CA 10141
4 Pages
-
C.A 10101
4 Pages
-
C.A 10001
2 Pages
-
CA 10002
2 Pages
-
VASD 40
2 Pages
-
ANALOGUE RANGE
2 Pages
-
DIGITAL RANGE
4 Pages
-
Laboratory Selection
4 Pages
-
Electrodes range
8 Pages
-
CA 755 - CA 757
4 Pages
-
C.A 732 C.A 703 C.A 702
2 Pages
-
C.A 745N
2 Pages
-
CA 6651
2 Pages
-
MX 531
2 Pages
-
C.A 6608 C.A 6609
2 Pages
-
CA 6117 – CA 6116N – CA 6113
8 Pages
-
C.A 6131 - C.A 6133
4 Pages
-
C.A 6460 C.A 6462
4 Pages
-
C.A 6472 C.A 6474
4 Pages
-
Earth/ground measurement guide
36 Pages
-
C.A 6470N
4 Pages
-
C.A 6416 C.A 6417
8 Pages
-
E Series
8 Pages
-
E25 & E27
2 Pages
-
B100 series
4 Pages
-
MiniFlex® SERIES
17 Pages
-
MH SERIES
5 Pages
-
DN SERIES
15 Pages
-
K SERIES
4 Pages
-
C100 series
18 Pages
-
YN SERIES
9 Pages
-
MN SERIES
16 Pages
-
MINI series
12 Pages
-
AmpFlex® series
13 Pages
-
CHAUVIN ARNOUX 2021
16 Pages
-
C.A 1621 C.A 1623 C.A 1631
4 Pages
Archived catalogs
-
MAP COMPACT NETWORK ANALYZER
2 Pages
-
ENERIUM RANGE
8 Pages
-
PANEL METERS
4 Pages
-
T82N
12 Pages
-
ANALOG AND DIGITAL
4 Pages
-
ELINK 61850
2 Pages
-
C.A 6681 LOCAT-N
4 Pages
-
Catalogue Multimetrix 2021
12 Pages
-
Temperature Sensors Catalogue
336 Pages
-
Current Clamps Catalogue
154 Pages
-
2016 Spring promotion
4 Pages
-
Temperature sensor
64 Pages
-
Handscope
4 Pages