1. Catalogs
  2. CHAUVIN ARNOUX
  3. C.A 5277, C.A 5275, C.A 5273
video corpo

C.A 5277, C.A 5275, C.A 5273
1 /4Pages

C.A 5277, C.A 5275, C.A 5273

C.A 5277, C.A 5275, C.A 5273
1 /4Pages

Catalog excerpts

C.A 5277, C.A 5275, C.A 5273-1

C.A 5277, C.A 5275, C.A 5273 TRMS AC, DC and AC+DC Digital Multimeters Category IV for safety, versatility for use in the field • Double 6,000-count backlit display with dual-mode remanent bargraph • VLowZ low-impedance voltage measurement with low-pass filter (electronic power supply) • Resolution from 10 μV and 1 μA • Ionization current • Quick response (5 measurements/s) and high crest factor • Resistance, continuity, frequency, temperature, capacitance, etc. • Min / Max / Peak functions and relative or differential measure

 Open the catalog to page 1
C.A 5277, C.A 5275, C.A 5273-2

The TRMS digital multimeter, a crucial tool for electricians Rugged and reliable, this instrument is ideal for tertiary, industrial, electrical or electrotechnical maintenance applications. It is equipped with all the classic functions offered by a generalpurpose multimeter and also includes advanced functions to facilitate measurements in the field. Exceptionally easy to read! The 3 multimeters in the C.A 5270 Series can be used in various sectors: g • eneral electrical applications • electromechanics h • eating and air-conditioning i • ndustry & tertiary sector • automotive sector b • uildings...

 Open the catalog to page 2
C.A 5277, C.A 5275, C.A 5273-3

Accurate measurements, useful functions and a range of great features! 12-bit TRMS fast acquisition & 5 measurements per second The signals measured may be distorted or disturbed. This type of acquisition ensures top-quality results whatever their form or nature. Measurement of the ionization current Boiler maintenance and gas-burner combustion testing require measurement and adjustment of the ionization current. The presence of this current of a few μA DC, flowing through the flame between the ionization probe and the earth, controls the gas supply. If there is a combustion problem, the absence...

 Open the catalog to page 3
C.A 5277, C.A 5275, C.A 5273-4

V AC VLowZ AC (low impedance + low-pass filter) V AC+DC Resolution Ranges Resolution Ranges A AC+DC Ω Audible continuity / Test diode Hz Ranges Typical accuracy Resolution Ranges Resolution Bandwidth Ranges Resolution Ranges Resolution Resolution Ranges Resolution Ranges Resolution Ranges Resolution Measurement range Resolution Hold Min / MAX (100 ms) Peak+ / Peak- (1 ms) Differential (∆X) / RELative (∆X/X%) measurement Automatic power-off Safety Ingress protection rating Power supply Dimensions / Weight UNITED KINGDOM Chauvin Arnoux Ltd Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury,...

 Open the catalog to page 4

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4  Pages

  2. TC CLIP

    2  Pages

  3. PROBIX

    4  Pages

  4. OX9302-BUS

    4  Pages

  5. C.A 6255

    4  Pages

  6. CA 6165

    4  Pages

  7. CBF01

    2  Pages

  8. MX 604

    2  Pages

  9. MX 409

    4  Pages

  10. CA 6528

    4  Pages

  11. MX 535

    4  Pages

  12. CA 6011

    4  Pages

  13. C.A 6418

    2  Pages

  14. PAC Series

    4  Pages

  15. ASYC IV

    8  Pages

  16. SCOPIX IV

    8  Pages

  17. MEMO P200

    2  Pages

  18. GRIDWATCH

    6  Pages

  19. ULYS MCM

    4  Pages

  20. C.A 7028

    3  Pages

  21. HypeReal

    4  Pages

  22. THYRITOP 600

    4  Pages

  23. THYRITOP 500

    3  Pages

  24. THYRITOP 200

    2  Pages

  25. THYRITOP 100

    2  Pages

  26. CA 8345

    12  Pages

  27. CA 8220

    4  Pages

  28. C.A 847

    1  Page

  29. C.A 895

    2  Pages

  30. C.A 1950

    4  Pages

  31. CA 1954

    4  Pages

  32. CA 1310

    2  Pages

  33. CA 1900

    2  Pages

  34. C.A 5011

    2  Pages

  35. F65

    4  Pages

  36. CA 6292

    4  Pages

  37. C.A 6240

    2  Pages

  38. C.A 6630

    2  Pages

  39. C.A 6121

    4  Pages

  40. CA 1550

    2  Pages

  41. C.A 1510

    4  Pages

  42. CA 1227

    2  Pages

  43. C.A 1110

    2  Pages

  44. C.A 1246

    2  Pages

  45. C.A40

    2  Pages

  46. CA 10141

    4  Pages

  47. C.A 10101

    4  Pages

  48. C.A 10001

    2  Pages

  49. CA 10002

    2  Pages

  50. VASD 40

    2  Pages

  51. DIGITAL RANGE

    4  Pages

  52. C.A 745N

    2  Pages

  53. CA 6651

    2  Pages

  54. MX 531

    2  Pages

  55. C.A 6470N

    4  Pages

  56. E Series

    8  Pages

  57. E25 & E27

    2  Pages

  58. B100 series

    4  Pages

  59. MH SERIES

    5  Pages

  60. DN SERIES

    15  Pages

  61. K SERIES

    4  Pages

  62. C100 series

    18  Pages

  63. YN SERIES

    9  Pages

  64. MN SERIES

    16  Pages

  65. MINI series

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.