C100 series - 1

Current clamps for AC current Pinces ampèremetriques pour courant AC "C 100" SERIES The "C100" series is a range of thirteen transformer clamps with all the advantages of our old "C30" series clamps whilst incorporating considerable improvements, particularly in the field of safety, ergonomics and performance: • 1,000 A measurement, excellent metrology, high accuracy, high level of linearity, symmetrical coil windings for minimum phase shift, pendular adjusting system for magnetic elements, maximum conductor diameter Ø 52 mm and also some models with μ metal core specially made for wattmeter use. • Innovative design: excellent ergonomics, handle with finger grips, assisted opening system for jaws (patented system), IEC 1010 600 V cat. III safety (industry and services), antislip protection, conductor antipinching system,... Non-contractual document All this technology and manufacturing quality has been combined to provide the best measurement possible without any complications. A "C100" series clamp is compatible with any instrument (multimeter, wattmeter, recorder, oscilloscope...) for safe measurement of AC currents without shutting down the installation.

Open the catalog to page 1
C100 series - 2

Current clamps for AC current Pinces ampèremetriques pour courant AC Non-contractual document

Open the catalog to page 2
C100 series - 3

Currentampèremetriques pour courant AC Pinces clamp for AC current Model C100 Current ELECTRICAL SPECIFICATIONS • • • • Current range: 0.1 A AC .. 1,200 A AC Current transformation ratio: 1000:1 Output signal: 1 mA AC / A AC (1 A to 1,000 A) Accuracy and phase shift (1): Primary current % Accuracy of output signal Phase shift Bandwidth: 30 Hz .. 10 kHz (-3 dB) Crest factor: ≤ 6 for a current ≤ 3,000 A peak (500 ARMS) Maximum currents: 1,000 A continuous for a frequency ≤ 1 kHz (limitation proportional to the inverse of frequency beyond) 1,200 A for 40 minutes max (interval between...

Open the catalog to page 3
C100 series - 4

Pinces clamps for AC current Currentampèremetriques pour courant AC Models C102 and C103 Current DESCRIPTION An electronic voltage limiter protects the output of the clamp, if the secondary circuit is opened accidentally. ELECTRICAL SPECIFICATIONS • • • • Current range: 0.1 A AC .. 1,200 A AC Current transformation ratio: 1000:1 Output signal: 1 mA AC / A AC (1 A to 1,000 A) Accuracy and phase shift (1): Primary current % Accuracy of output signal Phase shift Bandwidth: 30 Hz .. 10 kHz (-3 dB) Crest factor: ≤ 6 for a current ≤ 3,000 A peak (500 ARMS) Maximum currents: 1,000 A continuous for...

Open the catalog to page 4
C100 series - 5

Current clamps for AC current Pinces ampèremetriques pour courant AC Models C106 and C107 Current ELECTRICAL SPECIFICATIONS • • • Current range: 0.1 A AC .. 1,200 A AC Output signal: 1 mV AC / A AC (1 V for 1,000 A) Accuracy and phase shift (1): Primary current % Accuracy of output signal Phase shift Bandwidth: 30 Hz .. 10 kHz Crest factor: ≤ 6 for a current ≤ 3,000 A peak (500 ARMS) Maximum currents: 1,000 A continuous for a frequency ≤ 1 kHz (limitation proportional to the inverse frequency beyond) 1,200 A for 40 minutes max (interval between measurements > 20 minutes) Output impedance: 1...

Open the catalog to page 5
C100 series - 6

Current clamps for AC current Pinces ampèremetriques pour courant AC Models C112 and C113 Current DESCRIPTION Thanks to their excellent technical performance (phase shift and linearity), these μ-metal core clamps are highly recommended for wattmeter use. These clamps are protected at output against overvoltages. ELECTRICAL SPECIFICATIONS • • • • Current range: 0.001 A AC .. 1,200 A AC Current transformation ratio: 1000:1 Output signal: 1 mA AC / A AC (1 A for 1,000 A) Accuracy and phase shift (1): Primary current Phase shift % Accuracy of output signal Bandwidth: 30 Hz .. 10 kHz Crest...

Open the catalog to page 6
C100 series - 7

Current clamps for AC current Pinces ampèremetriques pour courant AC Models C116 and C117 Current DESCRIPTION Thanks to their excellent technical performance (phase shift and linearity), these μ-metal core clamps are highly recommended for wattmeter use. ELECTRICAL SPECIFICATIONS • • • Current range: 0.001 A AC .. 1,200 A AC Output signal: 1 mV AC / A AC (1 V for 1,000 A) Accuracy and phase shift (1): Primary current % Accuracy of output signal Phase shift Bandwidth: 30 Hz .. 10 kHz Crest factor: ≤ 6 for a current ≤ 2,000 A peak (300 ARMS) Maximum currents: 1,000 A continuous for a...

Open the catalog to page 7
C100 series - 8

Current clamp for AC current Pinces ampèremetriques pour courant AC Model C122 Current DESCRIPTION An electronic voltage-limiting system protects output of clamp when operating, if the secondary circuit is opened accidentally. ELECTRICAL SPECIFICATIONS • • • • Current range: 1 A AC .. 1,200 A AC Current transformation ratio: 1000:5 Output signal: 5 mA AC / A AC (5 A for 1,000 A) Accuracy and phase shift (1): Primary current Accuracy en % Phase shift Bandwidth: 30 Hz .. 10 kHz Crest factor: ≤ 6 for a current ≤ 3,000 A peak (500 ARMS) Maximum currents: 1,000 A continuous for a frequency ≤ 1...

Open the catalog to page 8
C100 series - 9

Current clamp for AC current Pinces ampèremetriques pour courant AC Model C148 Current Ratio Output DESCRIPTION An electronic voltage-limiting system protects output of clamp when operating if the secondary circuit is opened accidentally. ELECTRICAL SPECIFICATIONS • Current range: 1 A AC .. 300 A AC 1 A AC .. 600 A AC 1 A AC .. 1,200 A AC Current transformation ratio 250:5 500:5 1000:5 Output signal: 20 mA AC / A AC (5 A for 250 A) 10 mA AC / A AC (5 A for 500 A) 5 mA AC / A AC (5 A for 1,000 A) Accuracy and phase shift (1): I Primary current Phase shift Primary current Primary current...

Open the catalog to page 9
C100 series - 10

Current clamp for AC current Pinces ampèremetriques pour courant AC Model C148 MECHANICAL SPECIFICATIONS • • • • • I Operating temperature: -10 °C to +50 °C Storage temperature: -40 °C to +70 °C Influence of temperature: ≤ 0.15 % of output signal per 10 °K Relative humidity for operation: 0 to 85 % RH decreasing linearly above 35 °C Influence of relative humidity: From 10 % to 85 % RH 250 A calibre: < 0.6 % of output signal and < 2° on phase 500 A calibre: < 0.4 % of output signal and < 0.6° on phase 1,000 A calibre: < 0.2 % of output signal and < 0.2° on phase Operating altitude: 0 to 2,000...

Open the catalog to page 10

All CHAUVIN ARNOUX catalogs and technical brochures

  1. MEMO RANGE

    4 Pages

  2. TC CLIP

    2 Pages

  3. PROBIX

    4 Pages

  4. OX9302-BUS

    4 Pages

  5. C.A 6255

    4 Pages

  6. CA 6165

    4 Pages

  7. CBF01

    2 Pages

  8. MX 604

    2 Pages

  9. MX 409

    4 Pages

  10. CA 6528

    4 Pages

  11. MX 535

    4 Pages

  12. CA 6011

    4 Pages

  13. C.A 6418

    2 Pages

  14. PAC Series

    4 Pages

  15. ASYC IV

    8 Pages

  16. SCOPIX IV

    8 Pages

  17. MEMO P200

    2 Pages

  18. GRIDWATCH

    6 Pages

  19. ULYS MCM

    4 Pages

  20. C.A 7028

    3 Pages

  21. HypeReal

    4 Pages

  22. THYRITOP 600

    4 Pages

  23. THYRITOP 500

    3 Pages

  24. THYRITOP 200

    2 Pages

  25. THYRITOP 100

    2 Pages

  26. CA 8345

    12 Pages

  27. CA 8220

    4 Pages

  28. C.A 847

    1 Pages

  29. C.A 895

    2 Pages

  30. C.A 1950

    4 Pages

  31. CA 1954

    4 Pages

  32. CA 1310

    2 Pages

  33. CA 1900

    2 Pages

  34. C.A 5011

    2 Pages

  35. F65

    4 Pages

  36. CA 6292

    4 Pages

  37. C.A 6240

    2 Pages

  38. C.A 6630

    2 Pages

  39. C.A 6121

    4 Pages

  40. CA 1550

    2 Pages

  41. C.A 1510

    4 Pages

  42. CA 1227

    2 Pages

  43. C.A 1110

    2 Pages

  44. C.A 1246

    2 Pages

  45. C.A40

    2 Pages

  46. CA 10141

    4 Pages

  47. C.A 10101

    4 Pages

  48. C.A 10001

    2 Pages

  49. CA 10002

    2 Pages

  50. VASD 40

    2 Pages

  51. C.A 745N

    2 Pages

  52. CA 6651

    2 Pages

  53. MX 531

    2 Pages

  54. C.A 6470N

    4 Pages

  55. E Series

    8 Pages

  56. E25 & E27

    2 Pages

  57. B100 series

    4 Pages

  58. MH SERIES

    5 Pages

  59. DN SERIES

    15 Pages

  60. K SERIES

    4 Pages

  61. YN SERIES

    9 Pages

  62. MN SERIES

    16 Pages

  63. MINI series

    12 Pages

Archived catalogs

  1. PANEL METERS

    4 Pages

  2. T82N

    12 Pages

  3. ELINK 61850

    2 Pages

  4. Handscope

    4 Pages