BlueDiamond®:condensate removal pumps
16Pages

{{requestButtons}}

Catalog excerpts

BlueDiamond®:condensate removal pumps - 2

This iconic London building holds 2500 MAXI BLUE® PRO pumps. One of many superstructures using BLUEDIAMOND® technology around the world.

Open the catalog to page 2
BlueDiamond®:condensate removal pumps - 3

ABOUT US - PAGE 4 MICROBLUE® - PAGE 5 MINIBLUE® - PAGE 6 MINIBLUE® R - PAGE 7 MAXIBLUE® - PAGE 8 MAXI BLUE® PRO - PAGE 9 MEGABLUE® - PAGE 10 SENSING OPTIONS & ACCESSORIES - PAGE 11 ARCTIKBLUE® & SWAPOUT KIT - PAGE 12 WHY UPGRADE TO GYROK™ TECHNOLOGY - PAGE 14 PUMP SELECTOR GUIDE - PAGE 16 WHY UPGRAOTfO ROI ARY DIAPHRAGM TECHNOLOGY ir-’i. tWflOTTG* « - >l" 1 -j di iud cci cr-rr^D ni tir-ic

Open the catalog to page 3
BlueDiamond®:condensate removal pumps - 4

All BlueDiamond® condensate removal products are designed, developed, tooled and manufactured in house, meeting our strict approach to quality, stemming from our UK heritage and wide skill base. Our team of research and design engineers are dedicated to designing a range of pumps and accessories that not only benefit the end user but also the installer. Offering a new approach to efficiently, quietly and reliably removing large quantities of condensate, our R&D department has an eye for detail, meaning all products purchased are of the very highest standard. From design to packaging ready...

Open the catalog to page 4
BlueDiamond®:condensate removal pumps - 5

With no additional silencing accessories required, not only is the MICROBLUE® a silent running pump but it can also be mounted in any orientation whilst operating both wet and dry continuously. The MICROBLUE® is a dual voltage pump which uses proven thermistor level sensing technology to remove the risk of stuck or sunken float switches. SENSING OPTION PERFORMANCE The MicroBlue™ is the only ductless pump on the market that can remove sediment/ debris with no need of filters or regular servicing intervals. Smooth flow rate from the MicroBlue™ eliminates the necessity for any pulsating free...

Open the catalog to page 5
BlueDiamond®:condensate removal pumps - 6

Running either wet or dry, the MINIBLUE® is whisper quiet whilst reliably removing condensate and debris. Inherently reliable whilst self priming it gives peristaltic performance at the price of a piston pump. The MINIBLUE® is small enough to quickly fit, or retro fit, into any existing installation, saving both time and money. MINIBLUE® pump available with: TEMPERATURE SENSOR OAll of the BLUEDIAMOND® pumps have the ability to run dry without burning out. Enabling them to remove RUN any liquids, preventing organic growth inside the tubing. Quiet in all stages of operation and not only...

Open the catalog to page 6
BlueDiamond®:condensate removal pumps - 7

ROTARY DIAPHRAGM The MINIBLUE R® has been designed to combine performance, reliability and installation flexibility. Compact enough to mount remotely and incorporate the electronics needed to operate the unique thermistor controlled reservoir sensor, the MINIBLUE R® operates only when condensate is present. Supplied with a ducting kit and dedicated elbow kit to secure our fault free reservior. UNIT 3.5-8 KW SENSING OPTION PERFORMANCE MINIBLUE® pump available with: No servicing, no maintenace, no replacement parts. Nothing! A true fit and forget condensate pump. DIMENSIONS (MM) Non modular...

Open the catalog to page 7
BlueDiamond®:condensate removal pumps - 8

ROTARY DIAPHRAGM Designed for high humidity environments and with high performance, the MAXIBLUE® is ideally suited for mid range air conditioning systems. Its exceptional reliability is backed by a multi year warranty and with class leading performance/suction lift, the MAXIBLUE® is ideal for installations in environments that are both demanding and expensive to access for maintenance. SENSING OPTION PERFORMANCE MAXIBLUE® pump available with: RESERVOIR DRAINSTIK® SENSOR TEMPERATURE SENSOR BLUEDIAMOND® technology can deal with the variable outputs of condensate without the need for...

Open the catalog to page 8
BlueDiamond®:condensate removal pumps - 9

ROTARY DIAPHRAGM Designed for high humidity environments and with high performance, the MAXIBLUE® PRO is ideally suited for mid range air conditioning systems. Its exceptional reliability is backed by a multi year warranty and with class leading performance/suction lift, the MAXIBLUE®PRO is ideal for installations in environments that are both demanding and expensive to access for maintenance. PERFORMANCE MAXIBLUE® PRO package comes with: 1. 2. 3. 4. 5. 7. Ail ^ <S<S W %% X 1. 1x Blue stepped connector 2. 1x Black stepped connector 6. 3. 2x D14 Unex clip 4. 1x Reservoir 5. 2x...

Open the catalog to page 9
BlueDiamond®:condensate removal pumps - 10

ROTARY DIAPHRAGM The MEGABLUE® has a slimline, lightweight design and is whisper quiet, it also has the performance to overcome installation challenges and uses the BlueDiamond® revolutionary patented principle, making it inherently reliable. With the MEGABLUE® there's no cost penalty up front but big savings on installation and in service beyond. SENSING OPTION PERFORMANCE MEGABLUE® pump available with: TEMPERATURE SENSOR DRAINSTIK® SENSOR Accredited with our own industry pioneering 3 year warranty. We have faith in our reliability and so should you. BLUEDIAMOND® Pumps are the only...

Open the catalog to page 10
BlueDiamond®:condensate removal pumps - 12

PERFORMANCE APPLICATION Thanks to a strong steel casing the ARCTIKBLUE® can withstand far rougher treatment than many other cabinet pumps on the market. The ARCTIKBLUE® has the unique capability of being able to pump sludge that commonly builds up in refrigeration units. © LOW PROFILE © EASY TO INSTALL © SELF PRIMING © CAN REMOVE SLUDGE AND SLURRY © FAULT FREE SENSING © EASY AND SIMPLE TO FIT CONTACT US: © +44 (0)1932 355 277 (0) WWW.BLUEDIAMONDPUMF.COM INFO@BLUEDIAMONDPUMF.COM

Open the catalog to page 12
BlueDiamond®:condensate removal pumps - 13

ALARM SIGNAL INPUT VOLTAGE 230v AC, 50 Hz INLET FITTING THERMISTOR SENSOR (ENERGY EFFICENT) The presence of condensate trips the hi-low solid state level sensors to switch the pump on/off. This means that the pump is run only when condensate is produced and the alarm shuts off the unit in the case of a fault, restarting when clear. The slim filter probe, which houses the water sensors and high level alarm has no moving parts to become clogged or stuck making it an ideal alternative to existing float switches. FILTRATION Protecting the sensors is our swap out guard, the filter element can be...

Open the catalog to page 13

All CHARLES AUSTEN PUMPS LTD / BLUEDIAMOND PUMPS INC catalogs and technical brochures

  1. ETA SERIES

    2 Pages

  2. D SERIES

    2 Pages

  3. AC SERIES

    1 Pages

  4. PUMPS LTD

    16 Pages

  5. DL2 SERIES

    2 Pages

  6. CAPEX V2 DE

    2 Pages

  7. HC SERIES

    1 Pages

  8. ACCESORIES

    10 Pages

  9. ET series

    2 Pages

  10. OEM BROCHURE

    16 Pages

  11. V SERIES

    1 Pages

  12. T SERIES

    2 Pages

  13. D SERIES

    2 Pages

  14. LD10

    1 Pages

  15. RP12

    2 Pages

  16. RP120V

    1 Pages

  17. RP75P

    2 Pages

  18. MD series

    1 Pages

  19. VP SERIES

    1 Pages

  20. UV SERIES

    1 Pages

  21. SW SERIES

    1 Pages

  22. SSH SERIES

    1 Pages

  23. SS SERIES

    1 Pages

  24. QF SERIES

    1 Pages

  25. PC SERIES

    1 Pages

  26. LD SERIES

    1 Pages

  27. LD AC SERIES

    1 Pages

  28. HXF SERIES

    1 Pages

  29. HX SERIES

    1 Pages

  30. HR SERIES

    1 Pages

  31. HOSE CLIPS

    1 Pages

  32. HL-BT SERIES

    1 Pages

  33. HC SERIES

    1 Pages

  34. G SERIES

    1 Pages

  35. FS SERIES

    1 Pages

  36. ENVIROSURE

    1 Pages

  37. E SERIES

    1 Pages

  38. D SERIES

    1 Pages

  39. ACO77 SERIES

    1 Pages

  40. A SERIES

    1 Pages

  41. ETX ECO

    2 Pages

  42. E20000

    1 Pages

  43. RP75V

    2 Pages

  44. RP40P

    1 Pages

  45. D7 DE

    2 Pages

  46. Capex L2

    2 Pages

  47. D series

    4 Pages

  48. DL04

    1 Pages

  49. DL2 AC

    2 Pages

  50. Capex L1

    2 Pages

  51. RD1

    2 Pages

  52. RD5 AC

    2 Pages

  53. Innovac 60

    1 Pages

  54. LD5 AC

    1 Pages

  55. V Series

    1 Pages

  56. SSH Series

    1 Pages

  57. Enviro ET300

    2 Pages

  58. ET100

    2 Pages

  59. AC Series

    1 Pages

  60. HX Series

    1 Pages

  61. ET Alarm

    1 Pages

  62. Envirosure

    1 Pages

  63. HX88 Series

    1 Pages

  64. S Series

    2 Pages

  65. HC Series

    1 Pages

  66. DA1 series

    2 Pages

  67. LD2

    2 Pages

  68. LD Series

    2 Pages

Archived catalogs

  1. 12V AC Pumps

    1 Pages