Kemlux® III KS/KH Enclosed & Gasketed Hazardous Location
Open the catalog to page 1KEMLUX III KS/KH SERIES ® ENCLOSED & GASKETED / HAZARDOUS LOCATION Hubbell Lighting has the answer for your demanding lighting environments. The Kemlux III KS/KH lighting fixture meets your wet, harsh, corrosive, or hazardous needs. The Kemlux III KS/KH Series utilizes the optional Electro-Reg® ballast to give long life and reliable operation for metal halide lamps. The KS meets the demands of UL and CSA listed wet locations and NEMA 4 hosedown applications. The KH Series is designed for hazardous locations defined by Article 500 of the NEC® and UL 595 Marine. COPPER-FREE ALUMINUM HOUSING,...
Open the catalog to page 2CONTENTS FEATURES Mounting options cover a wide range of rigid and flexible pendant, ceiling, wall, right angle stanchion and 25° stanchion of varying threaded NPT entries. Minimum starting temperatures of –20°F for MV/MH and –40°F for HPS make specifying ballast/lamp type easy. Copper-free (<0.4%) aluminum housing, cover and guard with Lektrocote® powder polyester paint finish provides excellent corrosion resistance from most chemicals. Optic choices are engineered to meet the demands of your applications. Optics are available in impact-resistant glass globes, symmetric/asymmetric glass...
Open the catalog to page 3KEMLUX III KS/KH SERIES ® ENCLOSED & GASKETED / HAZARDOUS LOCATION The Kemlux III fixture is best ordered as a set of three components: mount, tank and optic. Once you have the base fixture add accessories as necessary for your application. The tank and optic can be picked from the chart under this fold out page. To select an optic, look at the description across the top of the chart and find the one that best describes your lighting needs. To select a tank for a classified area (KH III) use the T-Code charts in the back of the brochure and determine the maximum wattage/tank size/optic that...
Open the catalog to page 4Mogul Base Offering Cone Top Pendant Flexible Pendant Straight Stanchion High Wattage Offering Cone Top Pendant Flexible Pendant Straight Stanchion
Open the catalog to page 5ORDERING INFORMATION QUICK FIXTURE PART NUMBER GUIDE USE THIS FORM TO SELECT A STARTING POINT FOR YOUR KS/KH APPLICATION GLOBE 5.5" THREAD SIZE Lamp Type Wattage Type 1 refractor is used to direct Type 3 refractor is used to direct when light is needed in all areas the light along a narrow road or the light along a wider road or to or with an optional reflector to Series General lighting distribution. Used when light is needed in all areas BALLAST TANK GLOBE 7.75" THREAD SIZE General lighting distribution. Used or with an optional reflector to light an area along and out from a Tank Size...
Open the catalog to page 6POLYCARBONATE SHIELDED REFLECTOR ENCLOSED REFRACTOR TYPE II 12" SPIN TOP REFLECTOR TYPE V 12" SPIN TOP REFLECTOR Type 5 refractor is used to put An 18" spun aluminum reflector used primarily for food applications An aluminum spin top attached An aluminum spin top attached light in all directions around the with a sealed glass bottom lens. where a Class I Div. 1 listing is to a glass refractor with a Type II to a glass refractor with a Type V fixture. Used for general lighting. Directs light down below the required but exposed glass is not distribution. Good for roadways distribution. Used...
Open the catalog to page 7KEMLUX III KS/KH SERIES ® ENCLOSED & GASKETED / HAZARDOUS LOCATION ORDERING INFORMATION ORDERING EXAMPLE SERIES KS Kemlux® III KS (gray finish) KH Kemlux® III KH (tan finish) TANK TYPE C Low Wattage Mogul Base 5" D Low Wattage Mogul Base 8" E High Wattage Mogul Base 8" LAMP TYPE S High Pressure Sodium H Metal Halide P Pulse Start Metal Halide M Mercury Vapor E Electro-Reg® VOLTAGE (@ 60 Hz) 0 Quadri-Volt (120, 208, 240, 277V) 5 480V 6 Tri-Tap Canada (120, 277, 347V) 7 220V 8 220/240V 50 Hz MOUNTING TYPE A Pendant X Ceiling B Wall Bracket C Cone Top D Stanchion 25° S Stanchion Straight 90°...
Open the catalog to page 8KEMLUX III MOUNTING SPLICE BOXES Hub Size 3/4" 1" 11/4" 11/2" M-20 NOTE: When ordering, specify either KS or KH, e.g. KSA2B or KHA2B. FLEXIBLE PENDANT STRAIGHT STANCHION NOTE: Replace X with voltage: 0 = Quad-Tap®, 6 = TriTap, 5 = 480V. NOTE: When ordering, specify either KS or KH, e.g. KSCS05X or KHCS05X. KPSD40 KPA40 Standard Dome Angle Fiberglass White Fiberglass White Reflector Reflector Dia: 16" Dia: 16" HRD400 Deep Aluminum White Reflector Dia: 21" 1 For reference, KHE Spin Top optics fit KHD tanks, but KHC tanks and optics are recommended for low wattage Spin Top applications. KHC...
Open the catalog to page 9KEMLUX III KS/KH SERIES ® ENCLOSED & GASKETED / HAZARDOUS LOCATION DIMENSIONS MOUNTING ADAPTERS Cone Mount Wall Bracket Mount 6.75" (171 mm) KSC Ballast Tank 51/2" Optics Globe or Refractor KSAG17 Globe Guard KSC Ballast Tank KZRG1550 8" Spun Refractor 16.87" dia. (428 mm) 12.19" dia. (310 mm) KSC Ballast Tank KZRG 12" Spun Refractor Pendant Mount KSC Ballast Tank KG17 51/2" Optics Globe KPSD40 Dome Reflector
Open the catalog to page 10KXD Ballast Tank KG25 73/4" Optics Globe or KR25 Refractor KAG25S Wire Guard 18.25" dia. (464 mm) KXD Ballast Tank KER40 Enclosed Reflector KERG Guard 23.0" dia. (584 mm) KXD Ballast Tank KEP40 Optic 7.56" dia, (192 mm) KXE Ballast Tank KG40 Optics Globe KXE Ballast Tank 12" Spun Top Refractor Optics 23.0" dia, (584 mm) KXE Ballast Tank KEP40 Optic 1.62" (41 mm) 18.25" dia. (464 mm) KXE Ballast Tank KER40 Enclosed Reflector KERG Wire Guard 7.56" dia. (192 mm) 9.56" dia. (245 mm) KXE Ballast Tank KG40 Optics Globe KAG40S Wire Guard
Open the catalog to page 11KEMLUX III KS/KH SERIES ® 1 Data does not apply to luminaires with auxiliary quartz lighting; consult factory with requirements. The suitability of these fixtures for Class I Division 2/zone 2 locations must be determined for each application based on NEC® Articles 501.125(B) or 505. 2 KHC Series accepts 5 1/2” threaded optics. KHD Series accepts 7 3/4” optics. 1 Data does not apply to luminaires with auxiliary quartz lighting; consult factory with requirements. The suitability of these fixtures for Class I Division 2/zone 2 locations must be determined for each application based on NEC®...
Open the catalog to page 12All Chalmit catalogs and technical brochures
-
Superbay Series
16 Pages
-
Superwatt Gymnasium Lighting
2 Pages
-
LED - Solid State Lighting
4 Pages
-
Kemlux II Brochure
9 Pages
-
AW LED Retrofit
1 Pages
-
LED Highbay
3 Pages
-
Kemlux III LED
2 Pages
-
LUNABAY LED Brochure
2 Pages
-
LED Vaportite
2 Pages
-
NutriLED Brochure
9 Pages
-
AW LED Specification Page
1 Pages
-
12XPB Specification Sheet
3 Pages
-
Dokstar Specification Sheet
2 Pages