HUBBELL LIGHTING KEMLUX II KS/KH SERIES. THE HARSH/HAZARDOUS LIGHTING SOLUTION. ®

Open the catalog to page 1
Kemlux II Brochure - 2

Hubbell Lighting has the answer for your demanding lighting environ- ments. The Kemlux II KS/KH lighting fixture meets your wet, harsh, corrosive, or hazardous needs. The Kemlux II KS/KH Series utilizes the Electro-Reg" ballast to give long life and reliable operation for metal halide lamps. The KS meets the demands of UL and CSA listed wet locations and NEMA 4 hosedown. The KH Series is designed for hazardous locations defined by Article 500 of the NEC" and UL 595 Marine. Electro-Reg" metal halide • Long lamp life benefits of HPS, but with white light which saves maintenance dollars and...

Open the catalog to page 2
Kemlux II Brochure - 3

UL 1572: wet locations NEMA 4: hosedown CSA NRTL/C: CSA C22.2 no. 90-96 55°C Ambient UL 844: xtures for use in hazardous (classied) locations Class I, Division 2: Groups A, B, C, D Class II, Division 1 and 2: Groups E, F G* , Class III UL 595: Marine UL 1572: wet locations IP66: self-certied CSA NRTL/C: CSA C22.2 no. 90-96 and no. 137-M1981 * see T-Ratings for Group G listing Now available, Electro-Reg® metal halide ballast which provides long life, quick re-strike, and low lumen depreciation for metal halide lamps. Provided as an option. Available in metal halide (175, 250, 400 watt); high...

Open the catalog to page 3
Kemlux II Brochure - 4

SPECIFYING HAZARDOUS LIGHTING Many factors go into specifying hazardous lighting. Care must be taken in determining the classication of the hazardous location in which the xtures are being installed. Any qualied inspector, underwriter or re marshall can help determine a Classication of an area. The decisions which must be made are: KS/KH VARIATIONS CLASS (type of substance) Class I Gas or Vapor Class II Combustible Dust Class III Ignitable Fibers and Flyings GROUP (nature of substance) CLASS I Group A Test Gas Acetylene Group B Test Gas Hydrogen Group C Test Gas Ethylene Group D Test Gas...

Open the catalog to page 4
Kemlux II Brochure - 5

Ordering Information Kemlux II KS/KH Series ® SAMPLE CATALOG NUMBER Lamp Type SERIES KS Harsh/Severe KH Hazardous WATTAGE MEDIUM HOUSING 50 50 watt HPS 70 70 watt HPS 10 100 watt MV or HPS 15 150 watt HPS 17 175 watt MV, MH or Electro-Reg® MH 25 250 watt MV or MH LARGE HOUSING 25* 250 watt HPS 40 400 watt MV, MH, HPS, or Electro-Reg MH * 250 watt Electro-Reg MH. Consult factory. LAMP TYPE C Mercury Vapor H Metal Halide S High Pressure Sodium E Electro-Reg Metal Halide VOLTAGE 1 120V (50 watt HPS & Electro-Reg only) 2 208V (Electro-Reg) 3 240V (Electro-Reg) 4 277V (50 watt HPS & Electro-Reg...

Open the catalog to page 5
Kemlux II Brochure - 6

MEDIUM HOUSING GLOBE, GUARD, DOME REFLECTOR/POLYCARBONATE REFRACTOR LARGE HOUSING GLOBE, ANGLE DOME HOUSING AND MOUNTING HUB PLAN VIEW REFRACTOR GUARD ENCLOSED REFLECTOR GUARD MOUNTING HUBS

Open the catalog to page 6
Kemlux II Brochure - 7

Temperature Ratings (T-Ratings) HAZARDOUS LOCATION APPLICATION DATA: HIGH PRESSURE SODIUM Conguration Class I, Division 21 Class II, Div. 1 & 23–Class III, Div. 1 & 2 Maximum Class Max. Lamp Temp. Group(s) Max. Ext. Surface Temp. Ambient Temp. Rating °C Code Temp. Rating °C Code HAZARDOUS LOCATION APPLICATION DATA: METAL HALIDE & ELECTRO-REG Conguration Class I, Division 21 Class II, Div. 1 & 25–Class III, Div. 1 & 2 Maximum Class Max. Lamp Temp. Group(s) Max. Ext. Surface Temp. Ambient Temp. Rating °C Code Temp. Rating °C Code K-G / K-10 / K-04 / K-05 / K-15 GLASS GLOBE & GUARD INCLUDING...

Open the catalog to page 7
Kemlux II Brochure - 8

TEST NO: HP-07337 CATALOG NUMBER: KH/KS-10SX-GXX-10 TEST NO: HP-07341 CATALOG NUMBER: KH/KS-10SX-GXX-14 TEST NO: HP-07333 CATALOG NUMBER: KH/KS-10SX-GXX-15 TEST NO: HP-07268 CATALOG NUMBER: KH/KS-17HX-GXX-10 TEST DISTANCE: 36.3' REFLECTIVE MATERIAL: aluminum FINISH: white paint CLOSURE: globe with cast aluminum LAMP: 100W HPS EACH RATED: 9,500 lumens LINE POWER: 130 watts & dome reector TEST NO: HP-07270 CATALOG NUMBER: KH/KS-17HX-GXX-14 TEST DISTANCE: 36.3' REFLECTIVE MATERIAL: aluminum/steel reector FINISH: white paint CLOSURE: globe w/ wire guard & angle reector LAMP: 100W HPS EACH...

Open the catalog to page 8
Kemlux II Brochure - 9

HUBBELL LIGHTING, INC. WORLDWIDE LOCATIONS Hubbell Lighting products are manufactured to the highest international standards of quality. ISO 9002 certied facility. Country-wide certications are indicated throughout the catalog, including UL and CSA. In addition Hubbell Lighting products meet the existing NOM requirements for Mexico. Should you need to verify specic country requirements, please contact Hubbell Lighting, Inc. headquarters in Christiansburg, Virginia. UNITED STATES MIDDLE EAST HUBBELL LIGHTING, INC. 2000 Electric Way Christiansburg, VA 24073-2500 PHONE: (540) 382-6111 FAX:...