CG PRESSURE BOOSTING SYSTEMS
1 / 24Pages

Catalog excerpts

CG PRESSURE BOOSTING SYSTEMS - 1

Smart solutions. Strong relationships.

Open the catalog to page 1
CG PRESSURE BOOSTING SYSTEMS - 2

Pumps Division CGL PUMPS : A REPUTATION FOR EXCELLENCE... Crompton Greaves Ltd, is an Indian MNC, a part of US$4 BN Avantha Group conglomerate with an impressive global foot print operating in over 10 countries and has a leadership position in most of its lines of Business. CGL is designing and manufacturing Dependable innovative range of Centrifugal pumps for over 45 years and supplying to various core sectors of global economy like Water & Waste Water Management, Irrigation, Water Works, Fire Fighting, Processing, Power, Fertilizer, Refinery, Paper, Sugar & Textile Mills. Today CGL is the...

Open the catalog to page 2
CG PRESSURE BOOSTING SYSTEMS - 3

02 Type of Control System 5

Open the catalog to page 3
CG PRESSURE BOOSTING SYSTEMS - 4

CG PRESSURE BOOSTING SYSTEMS CG PRESSURE BOOSTING SYSTEMS Product Coding X XXXXXXXXXX Pump Model System Type No.of Pumps 20 No.of stages - 20 Horse Power Discharge m3/h Vertical Multistage / Horizontal Multistage Brand 1.0 Horse Power Pipe Size (25 x 25) No.of stage Product Series System Type ON/OFF SYSTEM - Single Pump ON/OFF SYSTEM - Double Pump VFD Model ON/OFF SYSTEM - Double Pump External

Open the catalog to page 4
CG PRESSURE BOOSTING SYSTEMS - 5

CG PRESSURE BOOSTING SYSTEMS Models : there is any damage to the wire, the system senses a phase missing and automatically stops the Pump) IP 55 Protection Power saving up to 60% Easy to Install Large Pressure Tank & Pressure switch is not required Soft Start/Soft Stop Increases the Pump life by more than 30% RS 485 Port Communication Connectivity Two Sets of Pressure Point Selection Digital Display of all details required Automatic Changeover of Pumps at every start up cycle No external control panel required Anti - Frost Protection High Temperature Protection CONTROL SYSTEM-1 ON/OFF...

Open the catalog to page 5
CG PRESSURE BOOSTING SYSTEMS - 6

CG 11 SERIES CG 11 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure Control System type - ON-OFF System Features Min. 1.5 bar Pressure Max. Pressure - Pump Shut off head Dry Running Protection Motor Protection IP 44 Insulation Class 'B' Pressure tank 24 litres Application Houses Apartments Hotel

Open the catalog to page 6
CG PRESSURE BOOSTING SYSTEMS - 7

CG 13 SERIES CG 13 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure 7.5 HP 220 V ± 10% - Single Phase 4I5 V ± 10% - Three Phase 13.3 A 15 bar Control System Type 3 (VFD model) Motor Protection CGHM : IP 44 CGVM : IP 54 Insulation Class CGHM : 'B' Class CGVM : 'F' Class Pressure tank Upto 2 HP, 24 litres Above 2 HP, 60 litres Application Houses Apartments Hotels ELECTRICAL & HYDRAULIC DATA S.No. Control System Input Voltage (50 Hz) Max Pressure Pressure setting obtainable (bar) up to (bar)

Open the catalog to page 7
CG PRESSURE BOOSTING SYSTEMS - 8

Control System Input Voltage (50 Hz) Max Pressure Pressure setting obtainable (bar) up to (bar) DIMENSION DETAILS

Open the catalog to page 8
CG PRESSURE BOOSTING SYSTEMS - 10

CG 22 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure Features Control two pump operation min 1.0 bar max 15 bar Dry running protection Control System type 2 (ON/OFF - Double pump) Motor Protection IP 44 Insulation Class 'B' Pressure Tank - 24 litres Application • Houses • Apartments • Hotels • Industries Control System Input Voltage (50 Hz)

Open the catalog to page 10
CG PRESSURE BOOSTING SYSTEMS - 11

CG 23 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure 7.5 HP 220 V ± 10% - Single Phase 4I5 V ± 10% - Three Phase 13.3 A 15 bar Control System Type 3 (VFD model) Motor Protection CGHM : IP 44 CGVM :IP 54 Insulation Class CGHM : 'B' Class CGVM : 'F' Class Pressure Tank 100 litres Application Houses Apartments Hotels ELECTRICAL & HYDRAULIC DATA S.No. Control System Input Voltage (50 Hz)

Open the catalog to page 11
CG PRESSURE BOOSTING SYSTEMS - 12

Control System Input Voltage (50 Hz) CGVM - Series CGHM - Series

Open the catalog to page 12
CG PRESSURE BOOSTING SYSTEMS - 14

CG 24 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure 7.5 + 7.5 HP 220 V ± 10% - Single Phase 4I5 V ± 10% - Three Phase 13.3 A 15 bar Control System Type 4 (Double Pump External) Motor Protection CGHM : IP 44 CGVM : IP 54 Insulation Class CGHM : 'B' Class CGVM : 'F' Class Pressure Tank 100 litres Application Houses Apartments Hotels ELECTRICAL & HYDRAULIC DATA S.No. 1 Control System Input Voltage (50 Hz)

Open the catalog to page 14
CG PRESSURE BOOSTING SYSTEMS - 15

Control System Input Voltage (50 Hz) CGHM - Series CGVM - Series

Open the catalog to page 15
CG PRESSURE BOOSTING SYSTEMS - 16

CG 24 SERIES DIMENSION DETAILS S.No.

Open the catalog to page 16
CG PRESSURE BOOSTING SYSTEMS - 17

CG 33 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure 7.5 HP 220 V ± 10% - Single Phase 4I5 V ± 10% - Three Phase 13.3 A 15 bar Control System Type 3 (VFD model) Motor Protection CGHM : IP 44 CGVM : IP 54 Insulation Class CGHM : 'B' Class CGVM : 'F' Class Pressure tank Upto 3 HP, 200 litres Above 5 HP, 500 litres Application • Houses • Apartments • Hotels ELECTRICAL & HYDRAULIC DATA S.No. Control System Input Voltage (50 Hz)

Open the catalog to page 17
CG PRESSURE BOOSTING SYSTEMS - 18

CGHM - Series CGVM - Series

Open the catalog to page 18
CG PRESSURE BOOSTING SYSTEMS - 19

CG 43 SERIES Operating Data Maximum HP Operating Voltage Maximum Current Operating Pressure 7.5 HP 220 V ± 10% - Single Phase 4I5 V ± 10% - Three Phase 13.3 A 15 bar Control System Type 3 (VFD model) Motor Protection CGHM : IP 44 CGVM : IP 54 Insulation Class CGHM : 'B' Class CGVM : 'F' Class Pressure tank Upto 3 HP, 200 litres Above 5 HP, 500 litres Application • Houses • Apartments • Hotels ELECTRICAL & HYDRAULIC DATA S.No. Input Voltage for System (50 Hz) Pressure setting upto (bar)

Open the catalog to page 19
CG PRESSURE BOOSTING SYSTEMS - 20

CGHM - Series CGVM - Series

Open the catalog to page 20
CG PRESSURE BOOSTING SYSTEMS - 22

Accessories Pressure Tanks Characteristics Vertical Tank : Horizontal Tank: Tanks ideally suited for: • Booster systems • Irrigation systems • Thermal expansion • Hydraulic hammer arresting Connectors Characteristics Material : Size : Brass, Stainless Steel All common sizes Pressure Gauge Characteristics Range : Connection Inlet : Float Switch Characteristics Voltage Range: Current Range: Protection : Cable length :

Open the catalog to page 22
CG PRESSURE BOOSTING SYSTEMS - 24

Crompton Greaves Limited Plot No. C-19 & A-28 MIDC, Ahmednagar - 414111 Regd. Office: CG House, 6th Floor, Dr Annie Besant Road, Worli, Mumbai - 400 030

Open the catalog to page 24

All CG Power Systems catalogs and technical brochures

  1. DC Motors

    10 Pages

  2. AC drives

    8 Pages

  3. STAMPING

    9 Pages

Archived catalogs

  1. switch gear

    2 Pages

  2. T&D System

    2 Pages