1. Catalogs
  2. CETONI GmbH
  3. heatedsyringe and heated tubing sleeves

heatedsyringe and heated tubing sleeves

heatedsyringe and heated tubing sleeves

Product catalog summary

Description
The document describes the NEMESYS Heating Accessories developed by cetoni, designed for applications requiring pre-heating of materials transported by pump equipment. This is essential for modifying physical characteristics like viscosity or for specific downstream processes. The extension is compatible with the NEMESYS Mid Pressure syringe pump, offering precision and control through its software.

Equipment Description
The system includes the QMIX TC2 heating equipment controller with two separate control channels, a heated syringe with a valve block available in various sizes (1/2.5/5/10 ml, SST), and a heated tubing sleeve with replaceable inner capillary (1/16” - 1/8” OD). The setup is managed via the Windows-based QMIXELEMENTS software, providing comprehensive control over the heating equipment and other cetoni products.

Standard Configuration
The standard setup comprises a NEMESYS mid pressure syringe pump, a heated syringe attachment, a QMIX TC heating controller, and a heated tubing sleeve. The system can be enhanced with a BASE 600XT for at-line configuration, complementing the BASE 120 for controlling the QMIX TC2 and driving the Qmix V and NEMESYS pump modules.

Technical Specification

  • Electrical Data: QMIX TC Ports include 2x Heater and 4x Temperature Sensor (PT 100), with power specifications of 2x 160 W for QMIX TC, max. 70 W per meter for heated tubing, and max. 150 W for the heated syringe.
  • Environment: Operating temperature ranges from 5 – 45°C, with storage temperatures from -40 – 75°C. Operating and storage humidity levels are 20 – 80%, non-condensing.
  • Operation: The maximum operating temperature for both the syringe and tubing is 200°C.

See more

Catalog excerpts

heatedsyringe and heated tubing sleeves-1

HEATING ACCESSORIES Technical Specification An increasing number of applications require a pre-heating of materials or media, which will be transported by the pump equipment. Uses include the modification of physical characteristics of the relevant materials (e.g. viscosity or native conditions) or particular needs for downstream processes. Electrical Data For such applications, cetoni developed a novel extension for the NEMESYS Mid Pressure syringe pump to handle tempered liquids with the well-known precision and comfortable control software. NEMESYS mid pressure module Heating controller - QMIX TC2 Heated syringe upgrade The standard configuration consists of a NEMESYS mid pressure syringe pump, heated syringe-attachment, heating-controller (QMIX TC) as well as the heated tubing sleeve with a replaceable inner capillary. Heated tubing sleeve connection of heated syringe Equipment QMIX TC2 heated syringe (incl. valve block) heated tubing sleeve Description heating equipment controller (2 separate control channels) 1 / 2.5 / 5 / 10 ml ,SST (custom materials on request) 1/16” - 1/8” OD (replaceable inner capillary) Automated Temperature Control via QmixELEMENTS The above picture shows a complete heating enhancement setup, including a BASE 600XT (at-line configuration) to drive the heated syringe plus sleeves via the QMIX TC2. This complements the BASE 120 that provides the control for the QMIX TC2 and also drives the Qmix V and NEMESYS pump modules. The Windows-based operating software QMIXELEMENTS, offers the full and comfortable access to all control parameters of your heating equipment as well as other cetoni products. Detail of the heated syringe attachment and tubing sleeves with electrical connections to QMIX TC2 module (power – white, sensors – orange

 Open the catalog to page 1

All CETONI GmbH catalogs and technical brochures

  1. Base Modules

    1  Page

  2. Syringe Pump

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.